ZRW230 Wall Mounted 3-Way Switch

This describes the Z-Wave device ZRW230, manufactured by ACT - Advanced Control Technologies with the thing type UID of act_zrw230_00_000.

ZRW230 product image

The ZRW230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

ZRW230 WALL MOUNTED SWITCH

The ZRW230 Wall Mounted 3-Way Switch is a component of the HomePro lighting control system.

This Wall Mounted Switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can be added to the system and will also act as repeaters if they support this function of repeating the signal received to other modules in the system.

As part of a Z-Wave network, the ZRW230 will also act as a wireless repeater to insure that commands intended for another device in the network are received. This is useful when the device would otherwise be out of the radio range of the wireless controller.

There are no field repairable assemblies on this unit.. If service is needed, the unit must be returned where purchased.

Inclusion Information

Including to the Network (Must be installed in its permanent location, not on test bench)

1. Setup the controller you are using to include a device into network.

2. Tap either the top or bottom of the switch once

Exclusion Information

Excluding from the Network

1. Setup the controller you are using to exclude a device from the network.

2. Tap either the top or the bottom of the switch once.

Channels

The following table summarises the channels available for the ZRW230 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ZRW230. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set Ignore Start Level Bit Set Ignore Start Level Bit When Transmitting Dim Commands
2 Suspend Group 4 Stop transmitting to devices that are “associated” into Group 4
3 Night Light LED behaviour of the ZRW230 switch
4 Invert Switch Switch (paddle) behaviour.
14 Enable Shade Control Group 2 The ZRW230 can operate shade control devices via its group 2
15 Enable Shade Control Group 3 The ZRW230 can operate shade control devices via its group 3
19 LED Transmission Indication LED Transmission Indication
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set Ignore Start Level Bit

Set Ignore Start Level Bit When Transmitting Dim Commands The ZRW230 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will not ignore the start level. The following option values may be configured -:

Value Description
0 Dimmer will not ignore the start level
1 Dimmer will ignore the start level

The manufacturer defined default value is 1 (Dimmer will ignore the start level).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Suspend Group 4

Stop transmitting to devices that are “associated” into Group 4 You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from the group. Setting parameter 2 to the value of 1 will stop the ZRW230 from transmitting to devices that are “associated” into Group 4. The following option values may be configured -:

Value Description
0 Enable transmitting to devices “associated” into Group 4
1 Stop transmitting to devices “associated” into Group 4

The manufacturer defined default value is 0 (Enable transmitting to devices “associated” into Group 4).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Night Light

LED behaviour of the ZRW230 switch The LED on the ZRW230 will by default, turn ON when the load attached is turned ON. To make the LED turn ON when the load attached is turned OFF instead, set parameter 3 to a value of 1. The following option values may be configured -:

Value Description
0 Turn LED ON when the load is turned ON
1 Turn LED ON when the load is turned OFF

The manufacturer defined default value is 0 (Turn LED ON when the load is turned ON).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Switch (paddle) behaviour. To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. The following option values may be configured -:

Value Description
0 Top of switch is ON, bottom is OFF
1 Top of switch is OFF, bottom is ON

The manufacturer defined default value is 0 (Top of switch is ON, bottom is OFF).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 14: Enable Shade Control Group 2

The ZRW230 can operate shade control devices via its group 2 The ZRW230 can operate shade control devices via its group 2 if this configuration parameter is set to 1. The following option values may be configured -:

Value Description
0 Disable operation of shade control devices via group 2
1 Enable operation of shade control devices via group 2

The manufacturer defined default value is 0 (Disable operation of shade control devices via group 2).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Enable Shade Control Group 3

The ZRW230 can operate shade control devices via its group 3 The ZRW230 can operate shade control devices via its group 3 if this configuration parameter is set to 1. The following option values may be configured -:

Value Description
0 Disable operation of shade control devices via group 3
1 Enable operation of shade control devices via group 3

The manufacturer defined default value is 0 (Disable operation of shade control devices via group 3).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 19: LED Transmission Indication

LED Transmission Indication The ZRW230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the ZRW230 is set to flicker for only 1 second. The following option values may be configured -:

Value Description
0 LED will not flicker
1 LED will flicker the entire time while transmitting
2 LED will flicker 1 second when it begins transmitting

The manufacturer defined default value is 2 (LED will flicker 1 second when it begins transmitting).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZRW230 supports 4 association groups.

Group 1: Tapping paddle once

This group supports 5 nodes.

Group 2: Tapping paddle twice

This group supports 5 nodes.

Group 3: Tapping paddle three times

This group supports 5 nodes.

Group 4: By command to the ZRW230

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.