ZDW103 Wall Mounted 3-Way Dimmer Receiver
This describes the Z-Wave device ZDW103, manufactured by ACT - Advanced Control Technologies with the thing type UID of act_zdw103_00_000
.
Wall Mounted 3-Way Dimmer Receiver
Channels
The following table summarises the channels available for the ZDW103 Wall Mounted 3-Way Dimmer Receiver.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Dimmer
Restore Last Value
Restore Last Dimming level on ON.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_restoreLastValue | |||
Data Type | BOOLEAN | Default Value | true | |
Options | Restore Last Value (true) | |||
Restore Full Brightness (false) |
Device Configuration
The following table provides a summary of the configuration parameters available in the ZDW103 Wall Mounted 3-Way Dimmer Receiver. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
1: Set Ignore Start Level Bit When Transmitting Dim Commands | Defines the behavior when transmitting dim commands |
2: Suspend Group 4 | Disable transmission of command to Group 4 |
3: Night Light | Defines the behavior of the blue LED. |
4: Invert Switch | Change the top of the switch to OFF and the bottom of the switch to ON. |
5: Ignore Start-Level (Receiving) | This dimmer will start dimming from its current level. |
6: Don’t Send Level Command After Transmitting Dim Commands | Change behavior of dim level information update |
7: On/Off Command Dim Step | Indicates how many levels the dimmer will change for each dimming step. |
8: On/Off Command Dim Rate | Sets the rate at which the dimmer changes the light level. |
9: Local Control Dim Step | Indicates how many levels the dimmer will change for each dimming step. |
10: Local Control Dim Rate | Sets the dim rate |
11: ALL ON/ALL OFF Dim Step | Indicates how many levels the dimmer will change for each dimming step. |
12: ALL ON/ALL OFF Dim Rate | Sets the dim rate for the all on/off command |
13: Disable Group 4 During a Dim Command | Change behavior of command to Group 4 during Dim Command |
14: Enable Shade Control Group 2 | Enable Shade Control Group 2 |
15: Enable Shade Control Group 3 | Enable Shade Control Group 3 |
19: LED Transmission Indication | Change behavior of LED during transmission to group 1-4 |
1: Group 1 | Tap once |
2: Group 2 | Tap twice |
3: Group 3 | Tap three time |
4: Group 4 | Group to update transmitter or controler |
1: Set Ignore Start Level Bit When Transmitting Dim Commands
Defines the behavior when transmitting dim commands
Overview
The ZDW103 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. To clear this bit, configure this parameter to the value of 0.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_1_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Use transmisison start level (0) | |||
Ignore transmisison start level (1) |
2: Suspend Group 4
Disable transmission of command to Group 4
Overview
You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “un-associating” those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW103 from transmitting to devices that are “associated” into Group 4.
It is possible that you may only want the units in Group 4 to track when the dimmer is being turned ON and OFF and not when dimming.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_2_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Enable transmission to Group 4 (0) | |||
Disable transmission to Group 4 (1) |
3: Night Light
Defines the behavior of the blue LED.
Overview
Default is Night Light mode where LED is on when switch is off.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_3_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | LED on when switch is ON (0) | |||
LED on when switch is OFF (1) |
4: Invert Switch
Change the top of the switch to OFF and the bottom of the switch to ON.
Overview
Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_4_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | No (0) | |||
Yes (1) |
5: Ignore Start-Level (Receiving)
This dimmer will start dimming from its current level.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_5_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | No (0) | |||
Yes (1) |
6: Don’t Send Level Command After Transmitting Dim Commands
Change behavior of dim level information update
Overview
When you press and hold the bottom of the ZDW103 paddle once, the Z-Wave devices that are associated into Group 1 are sent the Dim command. After you release the paddle, the ZDW103 follows up by commanding the devices to go to the same level of the ZDW103. By default, the ZDW103 is set not to do this. To enable ZDW103 to do this set this parameter to 0.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_6_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Send level command (0) | |||
Don’t send level command (1) |
7: On/Off Command Dim Step
Indicates how many levels the dimmer will change for each dimming step.
Property | Value |
---|---|
Configuration ID | config_7_1 |
Data Type | INTEGER |
Range | 1 to 99 |
Default Value | 1 |
8: On/Off Command Dim Rate
Sets the rate at which the dimmer changes the light level.
Overview
This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds
Property | Value |
---|---|
Configuration ID | config_8_1 |
Data Type | INTEGER |
Range | 1 to 255 |
Default Value | 3 |
9: Local Control Dim Step
Indicates how many levels the dimmer will change for each dimming step.
Property | Value |
---|---|
Configuration ID | config_9_1 |
Data Type | INTEGER |
Range | 1 to 99 |
Default Value | 1 |
10: Local Control Dim Rate
Sets the dim rate
Overview
This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dimmer will change.
Property | Value |
---|---|
Configuration ID | config_10_1 |
Data Type | INTEGER |
Range | 1 to 255 |
Default Value | 3 |
11: ALL ON/ALL OFF Dim Step
Indicates how many levels the dimmer will change for each dimming step.
Property | Value |
---|---|
Configuration ID | config_11_1 |
Data Type | INTEGER |
Range | 1 to 99 |
Default Value | 1 |
12: ALL ON/ALL OFF Dim Rate
Sets the dim rate for the all on/off command
Overview
This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dimmer will change.
Property | Value |
---|---|
Configuration ID | config_12_1 |
Data Type | INTEGER |
Range | 1 to 255 |
Default Value | 3 |
13: Disable Group 4 During a Dim Command
Change behavior of command to Group 4 during Dim Command
Overview
After the ZDW103 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to the ZDW103’s new level. To prevent the ZDW103 from commanding the Z-Wave devices in Group 4 during this particular occurrence, set Parameter 13 to the value of 1.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_13_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Enable transmission to Group 4 (0) | |||
Disable transmission to Group 4 (1) |
14: Enable Shade Control Group 2
Enable Shade Control Group 2
Overview
The ZDW103 can control shade control devices via its group 2 if this configuration parameter is set to 1.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_14_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disabled (0) | |||
Enabled (1) |
15: Enable Shade Control Group 3
Enable Shade Control Group 3
Overview
The ZDW103 can control shade control devices via its group 3 if this configuration parameter is set to 1.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_15_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disabled (0) | |||
Enabled (1) |
19: LED Transmission Indication
Change behavior of LED during transmission to group 1-4
Overview
The ZDW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the ZDW103 is set to flicker for only 1 second.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_19_1 | |||
Data Type | INTEGER | Default Value | 2 | |
Options | No flicker (0) | |||
Flicker during all transmission (1) | ||||
Flicker first second of transmission (2) |
1: Group 1
Tap once
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
2: Group 2
Tap twice
Property | Value |
---|---|
Configuration ID | group_2 |
Data Type | TEXT |
Range | to |
3: Group 3
Tap three time
Property | Value |
---|---|
Configuration ID | group_3 |
Data Type | TEXT |
Range | to |
4: Group 4
Group to update transmitter or controler
Property | Value |
---|---|
Configuration ID | group_4 |
Data Type | TEXT |
Range | to |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.