ZRM230 Wall Switch/Transmitter (2-gang)

This describes the Z-Wave device ZRM230, manufactured by ACT - Advanced Control Technologies with the thing type UID of act_zrm230_00_000.

Wall Switch/Transmitter (2-gang)

Overview

Radio Frequency Controlled, 6A, 230 VAC, European Wall Mounted 3-Way Switch, Dual Switch, Release 1.1  

The ZRM230 Wall Mounted 3-Way Switch is a component of the HomePro lighting control system. This Wall Mounted Switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can be added to the system and will also act as repeaters if they support this function of repeating the signal received to other modules in the system.  

Inclusion Information

Including to the Network (Must be installed in permanent location, not on test bench).

  1. Setup the controller you are using to include a device into network.
  2. Tap either the top or bottom of the left switch once  

Exclusion Information

  1. Setup the controller you are using to exclude a device from the network.
  2. Tap either the top or the bottom of the left switch once.  

Channels

The following table summarises the channels available for the ZRM230 Wall Switch/Transmitter (2-gang).

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZRM230 Wall Switch/Transmitter (2-gang). Detailed information on each parameter can be found below.

Parameter Description
1: Ignore start level Set ignore start level bit when transmitting dim commands.
2: Suspend Group 4 Disable transmitting commands to group 4 devices.
3: Night Light LED behaviour of the ZRM230.
4: Invert Switch Switch (paddle) behaviour.
14: Enable Shade Control Group 2 Operate shade control devices on group 2.
15: Enable Shade Control Group 3 Operate shade control devices on group 3.
19: LED Transmission Indication Z-Wave transmission LED settings.
20: Poll Group 2 Interval Poll Group 2 interval (minutes).
22: Poll Group 2 Group 2 poll control.
1: Left paddle (relais)  
2: Right paddle  
3: Right double click paddle  
4: Controller updates Group used to inform devices about the updates of the status of the device.

1: Ignore start level

Set ignore start level bit when transmitting dim commands.

Overview

The ZRM230 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will ignore the start level.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Ignore start level (0)      
  Do not ignore start level (1)      

2: Suspend Group 4

Disable transmitting commands to group 4 devices.

Overview

You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from the group. Setting parameter 2 to the value of 1 will stop the ZRM230 from transmitting todevices that are “associated” into Group 4.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Transmit to group 4 devices (0)      
  Stop transmit to group 4 devices (1)      

3: Night Light

LED behaviour of the ZRM230.

Overview

The LED on the ZRM230 will by default, turn ON when the load attached is turned ON. To make the LED turn ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Led when load on (0)      
  Led when load off (1)      

4: Invert Switch

Switch (paddle) behaviour.

Overview

To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options Invert off (0)      
  Invert on (1)      

14: Enable Shade Control Group 2

Operate shade control devices on group 2.

Overview

The ZRM230 can operate shade control devices via its group 2 if this configuration parameter is set to 1. 

Property Value
Configuration ID config_14_1
Data Type INTEGER
Range 0 to 1
Default Value 0

15: Enable Shade Control Group 3

Operate shade control devices on group 3.

Overview

The ZRM230 can operate shade control devices via its group 3 if this configuration parameter is set to 1. 

Property Value
Configuration ID config_15_1
Data Type INTEGER
Range 0 to 1
Default Value 0

19: LED Transmission Indication

Z-Wave transmission LED settings.

Overview

The ZRM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to notflicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the ZRM230 is set to flicker for only 1 second.  

Property Value      
Configuration ID config_19_1      
Data Type INTEGER   Default Value 2
Options No flicker (0)      
  Flicker for 1 second (1)      
  Flicker for 2 second (2)      

20: Poll Group 2 Interval

Poll Group 2 interval (minutes).

Overview

Poll Group 2 Interval (minutes), valid values = 1 through 255 (Default value is 2).

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 2

22: Poll Group 2

Group 2 poll control.

Overview

Poll Group 2, if value is 1, the ZRM230 will poll group 2 at the interval set in configuration Parameter 20.

Property Value
Configuration ID config_22_1
Data Type INTEGER
Range 0 to 1
Default Value 1

1: Left paddle (relais)

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Right paddle

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Right double click paddle

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Controller updates

Group used to inform devices about the updates of the status of the device.

Property Value
Configuration ID group_4
Data Type TEXT
Range to