ZRW230 Wall Mounted 3-Way Switch

This describes the Z-Wave device ZRW230, manufactured by ACT - Advanced Control Technologies with the thing type UID of act_zrw230_00_000.

Wall Mounted 3-Way Switch

Overview

ZRW230 WALL MOUNTED SWITCH

The ZRW230 Wall Mounted 3-Way Switch is a component of the HomePro lighting control system.

This Wall Mounted Switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can be added to the system and will also act as repeaters if they support this function of repeating the signal received to other modules in the system. 

As part of a Z-Wave network, the ZRW230 will also act as a wireless repeater to insure that commands intended for another device in the network are received. This is useful when the device would otherwise be out of the radio range of the wireless controller.

There are no field repairable assemblies on this unit.. If service is needed, the unit must be returned where purchased.

Inclusion Information

Including to the Network (Must be installed in its permanent location, not on test bench)

  1. Setup the controller you are using to include a device into network.

  2. Tap either the top or bottom of the switch once

Exclusion Information

Excluding from the Network

  1. Setup the controller you are using to exclude a device from the network.

  2. Tap either the top or the bottom of the switch once.

Channels

The following table summarises the channels available for the ZRW230 Wall Mounted 3-Way Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the ZRW230 Wall Mounted 3-Way Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Set Ignore Start Level Bit Set Ignore Start Level Bit When Transmitting Dim Commands
2: Suspend Group 4 Stop transmitting to devices that are “associated” into Group 4
3: Night Light LED behaviour of the ZRW230 switch
4: Invert Switch Switch (paddle) behaviour.
14: Enable Shade Control Group 2 The ZRW230 can operate shade control devices via its group 2
15: Enable Shade Control Group 3 The ZRW230 can operate shade control devices via its group 3
19: LED Transmission Indication LED Transmission Indication
1: Tapping paddle once  
2: Tapping paddle twice  
3: Tapping paddle three times  
4: By command to the ZRW230  

1: Set Ignore Start Level Bit

Set Ignore Start Level Bit When Transmitting Dim Commands

Overview

The ZRW230 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will not ignore the start level.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Dimmer will not ignore the start level (0)      
  Dimmer will ignore the start level (1)      

2: Suspend Group 4

Stop transmitting to devices that are “associated” into Group 4

Overview

You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from the group. Setting parameter 2 to the value of 1 will stop the ZRW230 from transmitting to devices that are “associated” into Group 4.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Enable transmitting to devices “associated” into Group 4 (0)      
  Stop transmitting to devices “associated” into Group 4 (1)      

3: Night Light

LED behaviour of the ZRW230 switch

Overview

The LED on the ZRW230 will by default, turn ON when the load attached is turned ON. To make the LED turn ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Turn LED ON when the load is turned ON (0)      
  Turn LED ON when the load is turned OFF (1)      

4: Invert Switch

Switch (paddle) behaviour.

Overview

To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options Top of switch is ON, bottom is OFF (0)      
  Top of switch is OFF, bottom is ON (1)      

14: Enable Shade Control Group 2

The ZRW230 can operate shade control devices via its group 2

Overview

The ZRW230 can operate shade control devices via its group 2 if this configuration parameter is set to 1.

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Disable operation of shade control devices via group 2 (0)      
  Enable operation of shade control devices via group 2 (1)      

15: Enable Shade Control Group 3

The ZRW230 can operate shade control devices via its group 3

Overview

The ZRW230 can operate shade control devices via its group 3 if this configuration parameter is set to 1.

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Disable operation of shade control devices via group 3 (0)      
  Enable operation of shade control devices via group 3 (1)      

19: LED Transmission Indication

LED Transmission Indication

Overview

The ZRW230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the ZRW230 is set to flicker for only 1 second.

Property Value      
Configuration ID config_19_1      
Data Type INTEGER   Default Value 2
Options LED will not flicker (0)      
  LED will flicker the entire time while transmitting (1)      
  LED will flicker 1 second when it begins transmitting (2)      

1: Tapping paddle once

Overview

Group 1 Control:

If you associate a Z-Wave device into Group 1, you can turn that device ON and OFF by tapping the top or bottom of the switch once. The load attached to the ZRW230 will also turn on or off.

Associating nodes into group 2 or 3 will cause a very slight delay before the command is transmitted to group 1 nodes.

You can brighten the controlled device by pushing and holding the top of the switch, dim by pushing and holding

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Tapping paddle twice

Overview

Group 2 Control:

If you associate a Z-Wave device into Group 2, you can turn that device ON and OFF by tapping the top or bottom of the switch twice.

You can brighten or dim devices by tapping the switch once then push and hold the top or bottom.

The load attached to the ZRW230 is not affected.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Tapping paddle three times

Overview

Group 3 Control:

If you associate a Z-Wave device into Group 3, you can turn that device ON or OFF by tapping the top or bottom of the switch three times.

You can brighten or dim devices by tapping the switch twice then push and hold the top or bottom.

The load attached to the ZRW230 is not affected.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: By command to the ZRW230

Overview

Group 4 Control:

If you associate a Z-Wave device into Group 4, that device will be commanded to turn on or off when the ZRW230 is commanded to turn on or off.

Caution: The ZRW230 will not transmit to Z-Wave devices in Group 4 if it is already in the state that the Z-Wave command commanded it to.

Property Value
Configuration ID group_4
Data Type TEXT
Range to