DSC06 Smart Energy Switch

This describes the Z-Wave device DSC06, manufactured by AEON Labs with the thing type UID of aeon_dsc06_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

DSC06 product image

The DSC06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSC06 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Sensor (power) sensor_power Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 15 configuration parameters available in the DSC06. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Multilevel Sensor Report Content  
80 Automatic Notifications Enable or disable automatic notifications
90 Enable/disable Parameter 91 and 92 Enables/disables parameter 91 and 92 below
91 Minimum change in wattage Minimum change in wattage to trigger event
92 Minimum change in wattage % Minimum change in wattage % to trigger event
100 Set 101 to 103 to default values  
101 Group 1 report  
102 Group 2 report  
103 Group 3 report  
110 Set 111 to 113 to default values  
111 Interval Group 1 The time interval (in seconds) for sending report to Group 1
112 Interval Group 2 The time interval (in seconds) for sending report to Group 2
113 Interval Group 3 The time interval (in seconds) for sending report to Group 3
254 Device Tag  
255 Device Reset  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Multilevel Sensor Report Content

The following option values may be configured -:

Value Description
0 Power
1 Voltage

The manufacturer defined default value is 0 (Power).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 80: Automatic Notifications

Enable or disable automatic notifications Enables automatic notifications to associated devices whenever there is a state change

(0=nothing, 1=hail CC, 2=basic CC report) The following option values may be configured -:

Value Description
0 Nothing
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Enable/disable Parameter 91 and 92

Enables/disables parameter 91 and 92 below

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum change in wattage

Minimum change in wattage to trigger event The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum change in wattage %

Minimum change in wattage % to trigger event The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Set 101 to 103 to default values

The following option values may be configured -:

Value Description
0 No change
1 Reset

The manufacturer defined default value is 0 (No change).

This parameter has the configuration ID config_100_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 101: Group 1 report

The following option values may be configured -:

Value Description
0 None
2 Multisensor Report
4 Meter Report (Watts)
8 Meter Report (kWh)
12 Meter Report Watts and kWh

The manufacturer defined default value is 8 (Meter Report (kWh)).

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Group 2 report

The following option values may be configured -:

Value Description
0 None
2 Multisensor Report
4 Meter Report (Watts)
8 Meter Report (kWh)
12 Meter Report Watts and kWh

The manufacturer defined default value is 0 (None).

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Group 3 report

The following option values may be configured -:

Value Description
0 None
2 Multisensor Report
4 Meter Report (Watts)
8 Meter Report (kWh)
12 Meter Report Watts and kWh

The manufacturer defined default value is 0 (None).

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 110: Set 111 to 113 to default values

The following option values may be configured -:

Value Description
0 No change
1 Reset

The manufacturer defined default value is 0 (No change).

This parameter has the configuration ID config_110_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 111: Interval Group 1

The time interval (in seconds) for sending report to Group 1

Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval Group 2

The time interval (in seconds) for sending report to Group 2

Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval Group 3

The time interval (in seconds) for sending report to Group 3

Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 254: Device Tag

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_254_2 and is of type INTEGER.

Parameter 255: Device Reset

The following option values may be configured -:

Value Description
0 No change
1 Reset

The manufacturer defined default value is 0 (No change).

This parameter has the configuration ID config_255_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC06 supports 1 association group.

Group 1: Status Reports

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SENSOR_MULTILEVEL_V3  
COMMAND_CLASS_METER_V2  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  