DSC08 Smart Energy Illuminator

This describes the Z-Wave device DSC08, manufactured by AEON Labs with the thing type UID of aeon_dsc08_00_000.

The DSC08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSC08 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 16 configuration parameters available in the DSC08. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Multilevel Sensor Report Content  
2 Make SES blink  
80 Automatic Notifications Enables automatic notifications to associated devices whenever there is a state change
90 Enable Parameter 91 Enables/disables parameter 91 and 92 below
91 Minimum change in wattage The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent.
92 Minimum change in wattage % The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent.
100 Set 100 to 103 to default  
101 Group 1 report  
102 Group 2 report  
103 Group 3 report  
110 Set 111 to 113 to default  
111 Interval group 1 The time interval of sending Report group 1
112 Interval group 1 The time interval of sending Report group 2
113 Interval group 1 The time interval of sending Report group 3
254 Device Tag  
255 Device Reset  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Multilevel Sensor Report Content

The following option values may be configured -:

Value Description
0 Power
1 Voltage

The manufacturer defined default value is 0 (Power).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 80: Automatic Notifications

Enables automatic notifications to associated devices whenever there is a state change

The following option values may be configured -:

Value Description
0 Nothing
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Enable Parameter 91

Enables/disables parameter 91 and 92 below

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum change in wattage

The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent.

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum change in wattage %

The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Set 100 to 103 to default

The following option values may be configured -:

Value Description
0 Reset

The manufacturer defined default value is 0 (Reset).

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 101: Group 1 report

The following option values may be configured -:

Value Description
2 Multisensor Report
4 Meter Report (Watts)
8 Meter Report (kWh)

The manufacturer defined default value is 8 (Meter Report (kWh)).

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Group 2 report

The following option values may be configured -:

Value Description
2 Multisensor Report
4 Meter Report (Watts)
8 Meter Report (kWh)

The manufacturer defined default value is 0.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Group 3 report

The following option values may be configured -:

Value Description
2 Multisensor Report
4 Meter Report (Watts)
8 Meter Report (kWh)

The manufacturer defined default value is 0.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 110: Set 111 to 113 to default

The following option values may be configured -:

Value Description
0 Reset

The manufacturer defined default value is 0 (Reset).

This parameter has the configuration ID config_110_1 and is of type INTEGER.

Parameter 111: Interval group 1

The time interval of sending Report group 1

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval group 1

The time interval of sending Report group 2

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval group 1

The time interval of sending Report group 3

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 254: Device Tag

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_254_2 and is of type INTEGER.

Parameter 255: Device Reset

This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Reset

The manufacturer defined default value is 0 (Reset).

This parameter has the configuration ID config_255_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC08 supports 1 association group.

Group 1: Status Reports

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_MULTILEVEL_V1  
COMMAND_CLASS_SWITCH_ALL_V0  
COMMAND_CLASS_SENSOR_MULTILEVEL_V3  
COMMAND_CLASS_METER_V2  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.