DSC10 Heavy Duty Smart Switch

This describes the Z-Wave device DSC10, manufactured by AEON Labs with the thing type UID of aeon_dsc10_00_000.

The DSC10 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSC10 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the DSC10. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Current Overload Protection See overview
20 Output Load Status Configure the output load status after re‐power on.
80 Notification on Status Change The type of report to send when the device status changes
90 Enables/disables parameter 91/92  
91 Minimum Change to send Report (Watt) The value represents the minimum change in wattage for a Report to be sent.
92 Minimum Change to send Report (%) The minimum change in wattage Percent for a report to be sent
200 Partner ID  
252 Lock/unlock Configuration Changes  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Current Overload Protection

See overview Load will be closed when the Current more than 39.5A and the time more than 5 seconds. The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Activate Overload Protection
1 Deactivate Overload Protection

The manufacturer defined default value is 0 (Activate Overload Protection).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 20: Output Load Status

Configure the output load status after re‐power on.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 Last Status
1 Always ON
2 Always OFF

The manufacturer defined default value is 0 (Last Status).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 80: Notification on Status Change

The type of report to send when the device status changes

The following option values may be configured -:

Value Description
0 Nothing
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Enables/disables parameter 91/92

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Enable parameters 91 and 92
1 Disable parameters 91 and 92

The manufacturer defined default value is 0 (Enable parameters 91 and 92).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in wattage for a Report to be sent.

Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

The minimum change in wattage Percent for a report to be sent

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 200: Partner ID

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Aeon Labs
1 Other

The manufacturer defined default value is 0 (Aeon Labs).

This parameter has the configuration ID config_200_1 and is of type INTEGER. This is a read only parameter.

Parameter 252: Lock/unlock Configuration Changes

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Unlocked
1 Locked

The manufacturer defined default value is 0 (Unlocked).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC10 supports 2 association groups.

Group 1: Group 1

This group supports 5 nodes.

Group 2: Group 2

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SCENE_ACTIVATION_V1  
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1  
COMMAND_CLASS_SENSOR_MULTILEVEL_V5  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2  
COMMAND_CLASS_HAIL_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  