DSC18 Micro Smart Energy Switch G2

This describes the Z-Wave device DSC18, manufactured by AEON Labs with the thing type UID of aeon_dsc18_00_000.

The DSC18 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSC18 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (watts) meter_watts Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (volts) meter_voltage Energy Number
Reset Meter meter_reset Energy Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset Meter

Reset the meter.

The meter_reset channel supports the Switch item and is in the Energy category.

Device Configuration

The following table provides a summary of the 13 configuration parameters available in the DSC18. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Make Micro Smart Switch Blink  
3 Current Overload Protection  
80 Notification on Status Change  
90 Automated sending of a Report triggered by minimal change of value.  
91 Minimum Change to send Report (Watt)  
92 Minimum Change to send Report (%)  
101 Which reports need to send automatically in timing intervals for group 1  
102 Which reports need to send automatically in timing intervals for group 2  
103 Which reports need to send automatically in timing intervals for group 3  
111 Interval to send out reports of group 1  
112 Interval to send out reports of group 2  
113 Interval to send out reports of group 3  
120 Turn External Button Mode  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Current Overload Protection

The following option values may be configured -:

Value Description
0 Deactivate
1 Activate

The manufacturer defined default value is 0 (Deactivate).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 80: Notification on Status Change

The following option values may be configured -:

Value Description
0 Deactivate
1 Hail CC Sent
2 Basic CC Report Sent

The manufacturer defined default value is 0 (Deactivate).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Automated sending of a Report triggered by minimal change of value.

The following option values may be configured -:

Value Description
0 Deavtivate
1 Activate

The manufacturer defined default value is 0 (Deavtivate).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 25.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 101: Which reports need to send automatically in timing intervals for group 1

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Which reports need to send automatically in timing intervals for group 2

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Which reports need to send automatically in timing intervals for group 3

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 111: Interval to send out reports of group 1

Values in the range 1 to 2678400 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval to send out reports of group 2

Values in the range 1 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval to send out reports of group 3

Values in the range 1 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 120: Turn External Button Mode

The following option values may be configured -:

Value Description
0 Momentary Button Mode
1 2 State Switch Mode
2 3 Way Switch Mode

The manufacturer defined default value is 255.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC18 supports 2 association groups.

Group 1: Target for automatic meter reports

This group supports 5 nodes.

Group 2: Target for automatic reports

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SCENE_ACTIVATION_V1  
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V0  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_CRC_16_ENCAP_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.