The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

ZW129 Dual Wallmote

This describes the Z-Wave device ZW129, manufactured by AEON Labs with the thing type UID of aeon_zw129_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZW129 product image

The ZW129 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The ZW129 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZW129 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Dimmer switch_dimmer DimmableLight Dimmer
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number
Scene Number scene_number   Number

Switch

Delete

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Dimmer

delete

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Electric meter (watts)

Delete - Device does not have meter channels

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Delete - Device does not have meter channels

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the ZW129. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Touch sound Enable/disable the touch sound.
2 Touch vibration Enable/disable the touch vibration.
3 Button slide Enable/disable the function of button slide.
4 Notification report Which notification to be sent to the associated devices.
39 Low battery value Set the low battery value
255 Reset the WallMote Quad Reset the WallMote Quad to factory default.

Parameter 1: Touch sound

Enable/disable the touch sound.

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Touch vibration

Enable/disable the touch vibration.

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Button slide

Enable/disable the function of button slide.

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Notification report

Which notification to be sent to the associated devices. To set which notification would be sent to the associated devices (Group 1) when pressing the buttons. When the parameter is set to 3, slide functionality on the buttons is activated. The following option values may be configured -:

Value Description
1 Central scene
3 Central scene and config

The manufacturer defined default value is 1 (Central scene).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 39: Low battery value

Set the low battery value

Values in the range 0 to 50 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_39_1 and is of type INTEGER.

Parameter 255: Reset the WallMote Quad

Reset the WallMote Quad to factory default.

The following option values may be configured -:

Value Description
0 Reset to factory default
1431655765 Reset and remove

The manufacturer defined default value is 0 (Reset to factory default).

This parameter has the configuration ID config_255_4_wo and is of type INTEGER. This is a write only parameter.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW129 supports 5 association groups.

Group 1: Lifeline

Z-Wave Plus Lifeline This group supports 1 nodes.

Group 2: Button 1 basic

On/off control via button 1 This group supports 5 nodes.

Group 3: Button 1 multilevel

Dim control via button 1 This group supports 5 nodes.

Group 4: Button 2 basic

On/off control via button 2 This group supports 5 nodes.

Group 5: Button 2 multilevel

Dim control via button 2 This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CENTRAL_SCENE_V0| Linked to BASIC| | COMMAND_CLASS_MULTI_CHANNEL_V0| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_CENTRAL_SCENE_V0| Linked to BASIC|

Endpoint 2

Command Class Comment
COMMAND_CLASS_CENTRAL_SCENE_V0 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.