DSB05 4 in One MultiSensor

This describes the Z-Wave device DSB05, manufactured by AEON Labs with the thing type UID of aeon_dsb05_00_000.

4 in One MultiSensor

Channels

The following table summarises the channels available for the DSB05 4 in One MultiSensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the DSB05 4 in One MultiSensor. Detailed information on each parameter can be found below.

Parameter Description
2: Wake up for 10 minutes when batteries are inserted  
3: On time On time before sending off command
4: Motion sensor  
5: Command to send when movement  
101: Which reports to send to group 1 Group 1 automatic report list
102: Which reports to send to group 2 Group 2 automatic report list
103: Which reports to send to group 3 Group 3 automatic report list
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
255: Reset to the default Configuration of all parameters Set to 1 to reset to factory default
1: Group 1 devices  

2: Wake up for 10 minutes when batteries are inserted

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options disable (default) (0)      
  enable (1)      

3: On time

On time before sending off command

Overview

How long should the device associated to multi sensor keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to next integer in minutes)

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 1 to 15300
Default Value 240

4: Motion sensor

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (1)      

5: Command to send when movement

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Send Basic Set (1)      
  send Sensor Binary report (2)      

101: Which reports to send to group 1

Group 1 automatic report list

Overview

The value is a combination number made up of the sum of the values for the individual sensors and battery.

The sensors have the values:

Temperature=32

Humidity=64

Lightlevel=128

Battery=1                           

Therefore if you want all sensors and the battery report set this value to 225 (recommended)

Property Value
Configuration ID config_101_4_000000FF
Data Type INTEGER
Range 0 to 225
Default Value 0

102: Which reports to send to group 2

Group 2 automatic report list

Overview

The value is a combination number made up of the sum of the values for the individual sensors and battery.

The sensors have the values:

Temperature=32

Humidity=64

Lightlevel=128

Battery=1                           

Therefore if you want all sensors and the battery report set this value to 225

Property Value
Configuration ID config_102_4_000000FF
Data Type INTEGER
Range 0 to 225
Default Value 0

103: Which reports to send to group 3

Group 3 automatic report list

Overview

The value is a combination number made up of the sum of the values for the individual sensors and battery.

The sensors have the values:

Temperature=32

Humidity=64

Lightlevel=128

Battery=1                           

Therefore if you want all sensors and the battery report set this value to 225

Property Value
Configuration ID config_103_4_000000FF
Data Type INTEGER
Range 0 to 225
Default Value 0

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

255: Reset to the default Configuration of all parameters

Set to 1 to reset to factory default

Property Value
Configuration ID config_255_1_wo
Data Type INTEGER
Range to
Default Value 0

1: Group 1 devices

Overview

Devices to be switched on when motion detected and off after on time

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.