DSB09 Home Energy Meter

This describes the Z-Wave device DSB09, manufactured by AEON Labs with the thing type UID of aeon_dsb09_00_000.

Home Energy Meter

Channels

The following table summarises the channels available for the DSB09 Home Energy Meter.

Channel Channel Id Channel Type UID Category Item Type
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset Meter meter_reset meter_reset Energy Switch
  battery-level system.battery-level    
Sensor (power) 1 sensor_power1 sensor_power Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Sensor (power) 2 sensor_power2 sensor_power Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Sensor (power) 3 sensor_power3 sensor_power Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the DSB09 Home Energy Meter. Detailed information on each parameter can be found below.

Parameter Description
1: Voltage Voltage to calculate wattage from amperage.
3: Selective Reporting Enable/disable selective reporting
4: Current Threshold - Whole HEM Threshold change in wattage to induce an automatic report (Whole HEM).
5: Current Threshold - Clamp 1 Threshold change in wattage to induce an automatic report (Clamp 1). (Valid values 0-60000…
6: Current Threshold - Clamp 2 Threshold change in wattage to induce an automatic report (Clamp 2). (Valid values 0-60000…
7: Current Threshold - Clamp 3 Threshold change in wattage to induce an automatic report (Clamp 3). (Valid values 0-60000…
8: Percent Change - Whole HEM Percentage change in wattage to induce an automatic report (Whole HEM). (Valid values 0-10…
9: Percent Change - Clamp 1 Percentage change in wattage to induce an automatic report (Clamp 1). (Valid values 0-100)
10: Percent Change - Clamp 2 Percentage change in wattage to induce an automatic report (Clamp 2). (Valid values 0-100)
11: Percent Change - Clamp 3 Percentage change in wattage to induce an automatic report (Clamp 3). (Valid values 0-100)
101: Which reports need to send automatically for group 1 Sum values of all wanted reports (see Overview)
102: Which reports need to send automatically for group 2 Sum values of all wanted reports (see Overview)
103: Which reports need to send automatically for group 3 Sum values of all wanted reports (see Overview)
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
255: Reset to Factory Reset all settings to factory defaults
1: Report group 1  
2: Report group 2  
3: Report group 3  

1: Voltage

Voltage to calculate wattage from amperage.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 32000
Default Value 240

3: Selective Reporting

Enable/disable selective reporting

Overview

When selective reporting is disabled, unit will send a report every X seconds, as configured in items 101-103. When selective reporting is enabled, unit will send a report if thresholds in items 4-7, or percentages in items 8-11, are exceeded. This is used to reduce network traffic. Sum the following values for the source of the reports to be selectively reported:

0        ->   Disable Selective Reporting

1        ->   Whole HEM

2        ->   Clamp 1

4        ->   Clamp 2

8        ->   Clamp 3

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 15
Default Value 0

4: Current Threshold - Whole HEM

Threshold change in wattage to induce an automatic report (Whole HEM).

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

5: Current Threshold - Clamp 1

Threshold change in wattage to induce an automatic report (Clamp 1). (Valid values 0-60000)

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

6: Current Threshold - Clamp 2

Threshold change in wattage to induce an automatic report (Clamp 2). (Valid values 0-60000)

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

7: Current Threshold - Clamp 3

Threshold change in wattage to induce an automatic report (Clamp 3). (Valid values 0-60000)

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

8: Percent Change - Whole HEM

Percentage change in wattage to induce an automatic report (Whole HEM). (Valid values 0-100)

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 100
Default Value 50

9: Percent Change - Clamp 1

Percentage change in wattage to induce an automatic report (Clamp 1). (Valid values 0-100)

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 100
Default Value 50

10: Percent Change - Clamp 2

Percentage change in wattage to induce an automatic report (Clamp 2). (Valid values 0-100)

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 100
Default Value 50

11: Percent Change - Clamp 3

Percentage change in wattage to induce an automatic report (Clamp 3). (Valid values 0-100)

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 100
Default Value 50

101: Which reports need to send automatically for group 1

Sum values of all wanted reports (see Overview)

Overview

1        ->   Battery Report

2        ->   MultiSensor Report for Watt (whole device)

4        ->   Meter Report for Watt (whole device)

8        ->   Meter Report for kWh (whole device)

256     ->   Meter Report for Watt (clamp 1)

512     ->   Meter Report for Watt (clamp 2)

1024   ->   Meter Report for Watt (clamp 3)

2048   ->   Meter Report for kWh (clamp 1)

4096   ->   Meter Report for kWh (clamp 2)

8192   ->   Meter Report for kWh (clamp 3)

NOTE: If a report is included in more then one Report Group, it will only be sent in the Report Group with the most recently updated configuration parameter.

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 16383
Default Value 8

102: Which reports need to send automatically for group 2

Sum values of all wanted reports (see Overview)

Overview

1        ->   Battery Report

2        ->   MultiSensor Report for Watt (whole device)

4        ->   Meter Report for Watt (whole device)

8        ->   Meter Report for kWh (whole device)

256     ->   Meter Report for Watt (clamp 1)

512     ->   Meter Report for Watt (clamp 2)

1024   ->   Meter Report for Watt (clamp 3)

2048   ->   Meter Report for kWh (clamp 1)

4096   ->   Meter Report for kWh (clamp 2)

8192   ->   Meter Report for kWh (clamp 3)

NOTE: If a report is included in more then one Report Group, it will only be sent in the Report Group with the most recently updated configuration parameter.

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 16383
Default Value 8

103: Which reports need to send automatically for group 3

Sum values of all wanted reports (see Overview)

Overview

1        ->   Battery Report

2        ->   MultiSensor Report for Watt (whole device)

4        ->   Meter Report for Watt (whole device)

8        ->   Meter Report for kWh (whole device)

256     ->   Meter Report for Watt (clamp 1)

512     ->   Meter Report for Watt (clamp 2)

1024   ->   Meter Report for Watt (clamp 3)

2048   ->   Meter Report for kWh (clamp 1)

4096   ->   Meter Report for kWh (clamp 2)

8192   ->   Meter Report for kWh (clamp 3)

NOTE: If a report is included in more then one Report Group, it will only be sent in the Report Group with the most recently updated configuration parameter.

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 16383
Default Value 8

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

255: Reset to Factory

Reset all settings to factory defaults

Overview

Reset all settings in unit to factory settings.  If you’re getting crazy voltage readings in a unit after upgrading firmware, use this then reconfigure the unit.

Property Value      
Configuration ID config_255_4_wo      
Data Type INTEGER   Default Value 0
Options Do nothing (0)      
  Reset to factory defaults (1)      

1: Report group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Report group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Report group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.