DSB28 Home Energy Meter G2

This describes the Z-Wave device DSB28, manufactured by AEON Labs with the thing type UID of aeon_dsb28_00_000.

Home Energy Meter G2

Channels

The following table summarises the channels available for the DSB28 Home Energy Meter G2.

Channel Channel Id Channel Type UID Category Item Type
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Reset Meter meter_reset meter_reset Energy Switch
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number
Electric meter (volts) 3 meter_voltage3 meter_voltage Energy Number
Electric meter (amps) 3 meter_current3 meter_current Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the DSB28 Home Energy Meter G2. Detailed information on each parameter can be found below.

Parameter Description
2: Reverse clamping If the reverse clamping pliers, negative power is detected.
3: Selective Reporting Enable selective reporting only when power change reaches a certain threshold or percentag…
4: Current Threshold - Whole HEM Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-6000…
5: Current Threshold - Clamp 1 Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000)
6: Current Threshold - Clamp 2 Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000)
7: Current Threshold - Clamp 3 Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000)
8: Percent Change - Whole HEM Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100…
9: Percent Change - Clamp 1 Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100)
10: Percent Change - Clamp 2 Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100)
11: Percent Change - Clamp 3 Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100)
101: Which reports need to send automatically for group 1 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt …
102: Which reports need to send automatically for group 2 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt …
103: Which reports need to send automatically for group 3 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt …
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
255: Factory Reset Reset all settings to factory defaults
1: Group 1  
2: Group 2  
3: Group 3  

2: Reverse clamping

If the reverse clamping pliers, negative power is detected.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

3: Selective Reporting

Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. (Bit 0: Whole HEM , Bit 1:Clamp 1, Bit 2:Clamp 2, Bit 3:Clamp 3)

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 16
Default Value 1

4: Current Threshold - Whole HEM

Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000)

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

5: Current Threshold - Clamp 1

Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000)

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

6: Current Threshold - Clamp 2

Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000)

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

7: Current Threshold - Clamp 3

Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000)

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 0 to 60000
Default Value 50

8: Percent Change - Whole HEM

Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100)

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 100
Default Value 50

9: Percent Change - Clamp 1

Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100)

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 100
Default Value 50

10: Percent Change - Clamp 2

Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100)

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 100
Default Value 50

11: Percent Change - Clamp 3

Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100)

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 100
Default Value 50

101: Which reports need to send automatically for group 1

1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 1061109568
Default Value 8

102: Which reports need to send automatically for group 2

1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 1061109568
Default Value 8

103: Which reports need to send automatically for group 3

1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 1061109568
Default Value 8

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

255: Factory Reset

Reset all settings to factory defaults

Overview

If you upgrade firmware and are seeing crazy or impossible numbers, reset to factory then reconfigure unit.

Property Value      
Configuration ID config_255_1_wo      
Data Type INTEGER   Default Value 0
Options Do nothing (0)      
  RESET TO FACTORY DEFAULTS (1)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.