DSB28 Home Energy Meter G2
This describes the Z-Wave device DSB28, manufactured by AEON Labs with the thing type UID of aeon_dsb28_00_000
.
Home Energy Meter G2
Channels
The following table summarises the channels available for the DSB28 Home Energy Meter G2.
Channel |
Channel Id |
Channel Type UID |
Category |
Item Type |
Electric meter (watts) |
meter_watts |
meter_watts |
Energy |
Number |
Electric meter (amps) |
meter_current |
meter_current |
Energy |
Number |
Electric meter (volts) |
meter_voltage |
meter_voltage |
Energy |
Number |
Electric meter (kWh) |
meter_kwh |
meter_kwh |
Energy |
Number |
Reset Meter |
meter_reset |
meter_reset |
Energy |
Switch |
Electric meter (watts) 1 |
meter_watts1 |
meter_watts |
Energy |
Number |
Electric meter (amps) 1 |
meter_current1 |
meter_current |
Energy |
Number |
Electric meter (volts) 1 |
meter_voltage1 |
meter_voltage |
Energy |
Number |
Electric meter (kWh) 1 |
meter_kwh1 |
meter_kwh |
Energy |
Number |
Electric meter (watts) 2 |
meter_watts2 |
meter_watts |
Energy |
Number |
Electric meter (amps) 2 |
meter_current2 |
meter_current |
Energy |
Number |
Electric meter (volts) 2 |
meter_voltage2 |
meter_voltage |
Energy |
Number |
Electric meter (kWh) 2 |
meter_kwh2 |
meter_kwh |
Energy |
Number |
Electric meter (watts) 3 |
meter_watts3 |
meter_watts |
Energy |
Number |
Electric meter (volts) 3 |
meter_voltage3 |
meter_voltage |
Energy |
Number |
Electric meter (amps) 3 |
meter_current3 |
meter_current |
Energy |
Number |
Electric meter (kWh) 3 |
meter_kwh3 |
meter_kwh |
Energy |
Number |
Device Configuration
The following table provides a summary of the configuration parameters available in the DSB28 Home Energy Meter G2.
Detailed information on each parameter can be found below.
Parameter |
Description |
2: Reverse clamping |
If the reverse clamping pliers, negative power is detected. |
3: Selective Reporting |
Enable selective reporting only when power change reaches a certain threshold or percentag… |
4: Current Threshold - Whole HEM |
Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-6000… |
5: Current Threshold - Clamp 1 |
Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000) |
6: Current Threshold - Clamp 2 |
Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000) |
7: Current Threshold - Clamp 3 |
Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000) |
8: Percent Change - Whole HEM |
Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100… |
9: Percent Change - Clamp 1 |
Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100) |
10: Percent Change - Clamp 2 |
Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100) |
11: Percent Change - Clamp 3 |
Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100) |
101: Which reports need to send automatically for group 1 |
1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt … |
102: Which reports need to send automatically for group 2 |
1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt … |
103: Which reports need to send automatically for group 3 |
1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt … |
111: Interval to send out reports of group 1 |
|
112: Interval to send out reports of group 2 |
|
113: Interval to send out reports of group 3 |
|
255: Factory Reset |
Reset all settings to factory defaults |
1: Group 1 |
|
2: Group 2 |
|
3: Group 3 |
|
2: Reverse clamping
If the reverse clamping pliers, negative power is detected.
Property |
Value |
|
|
|
Configuration ID |
config_2_1 |
|
|
|
Data Type |
INTEGER |
|
Default Value |
0 |
Options |
Disabled (0) |
|
|
|
|
Enabled (1) |
|
|
|
3: Selective Reporting
Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. (Bit 0: Whole HEM , Bit 1:Clamp 1, Bit 2:Clamp 2, Bit 3:Clamp 3)
Property |
Value |
Configuration ID |
config_3_1 |
Data Type |
INTEGER |
Range |
0 to 16 |
Default Value |
1 |
4: Current Threshold - Whole HEM
Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000)
Property |
Value |
Configuration ID |
config_4_2 |
Data Type |
INTEGER |
Range |
0 to 60000 |
Default Value |
50 |
5: Current Threshold - Clamp 1
Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000)
Property |
Value |
Configuration ID |
config_5_2 |
Data Type |
INTEGER |
Range |
0 to 60000 |
Default Value |
50 |
6: Current Threshold - Clamp 2
Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000)
Property |
Value |
Configuration ID |
config_6_2 |
Data Type |
INTEGER |
Range |
0 to 60000 |
Default Value |
50 |
7: Current Threshold - Clamp 3
Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000)
Property |
Value |
Configuration ID |
config_7_2 |
Data Type |
INTEGER |
Range |
0 to 60000 |
Default Value |
50 |
8: Percent Change - Whole HEM
Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100)
Property |
Value |
Configuration ID |
config_8_1 |
Data Type |
INTEGER |
Range |
0 to 100 |
Default Value |
50 |
9: Percent Change - Clamp 1
Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100)
Property |
Value |
Configuration ID |
config_9_1 |
Data Type |
INTEGER |
Range |
0 to 100 |
Default Value |
50 |
10: Percent Change - Clamp 2
Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100)
Property |
Value |
Configuration ID |
config_10_1 |
Data Type |
INTEGER |
Range |
0 to 100 |
Default Value |
50 |
11: Percent Change - Clamp 3
Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100)
Property |
Value |
Configuration ID |
config_11_1 |
Data Type |
INTEGER |
Range |
0 to 100 |
Default Value |
50 |
101: Which reports need to send automatically for group 1
1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W
Property |
Value |
Configuration ID |
config_101_4 |
Data Type |
INTEGER |
Range |
0 to 1061109568 |
Default Value |
8 |
102: Which reports need to send automatically for group 2
1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W
Property |
Value |
Configuration ID |
config_102_4 |
Data Type |
INTEGER |
Range |
0 to 1061109568 |
Default Value |
8 |
103: Which reports need to send automatically for group 3
1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W
Property |
Value |
Configuration ID |
config_103_4 |
Data Type |
INTEGER |
Range |
0 to 1061109568 |
Default Value |
8 |
111: Interval to send out reports of group 1
Property |
Value |
Configuration ID |
config_111_4 |
Data Type |
INTEGER |
Range |
1 to 2678400 |
Default Value |
720 |
112: Interval to send out reports of group 2
Property |
Value |
Configuration ID |
config_112_4 |
Data Type |
INTEGER |
Range |
1 to 2678400 |
Default Value |
720 |
113: Interval to send out reports of group 3
Property |
Value |
Configuration ID |
config_113_4 |
Data Type |
INTEGER |
Range |
1 to 2678400 |
Default Value |
720 |
255: Factory Reset
Reset all settings to factory defaults
Overview
If you upgrade firmware and are seeing crazy or impossible numbers, reset to factory then reconfigure unit.
Property |
Value |
|
|
|
Configuration ID |
config_255_1_wo |
|
|
|
Data Type |
INTEGER |
|
Default Value |
0 |
Options |
Do nothing (0) |
|
|
|
|
RESET TO FACTORY DEFAULTS (1) |
|
|
|
1: Group 1
Property |
Value |
Configuration ID |
group_1 |
Data Type |
TEXT |
Range |
to |
2: Group 2
Property |
Value |
Configuration ID |
group_2 |
Data Type |
TEXT |
Range |
to |
3: Group 3
Property |
Value |
Configuration ID |
group_3 |
Data Type |
TEXT |
Range |
to |