DSB45 Water Sensor

This describes the Z-Wave device DSB45, manufactured by AEON Labs with the thing type UID of aeon_dsb45_00_000.

Water Sensor

Wakeup Information

To wake up the sensor, don’t push the wake up button, as it does nothing.  Instead, tap the zwave button once.  Use wake up button to put back to sleep immediately.

Press WakeUp button or hold z-wave button

The Water Sensor will keep waking up for 8 seconds after sending the wake up notification command.
The Water Sensor will keep waking up for 8 seconds to waiting for the next command after receiving a command.
The Water Sensor will be woken up for 10 minutes when power is on (configurable).
There are 3 ways to exit the Wake up 10 minutes state:

  1. Triple click the tamper switch, and the Water Sensor will sleep immediately
  2. Receive the “Wake up no more information CC” command , sleep right now;
  3. Receive the other command except “Wake up no more information CC” , the Water Sensor will wake up for 8 seconds and then go to sleep.

Channels

The following table summarises the channels available for the DSB45 Water Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Flood Alarm alarm_flood alarm_flood Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the DSB45 Water Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Sensor Binary Report Toggle the sensor binary report value
2: Wake up Enable wake up 10 minutes when the power is switched on.
3: Basic set value Toggle the basic set value when the Magnet switch is opened /closed.
121: Reports that will be sent configuration Value 4(LSB)
121: Parameter 121 Value 3 See documentation
1: Group 1  

1: Sensor Binary Report

Toggle the sensor binary report value

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Open: 00, Close: FF (0)      
  Open: FF, Close: 00 (1)      

2: Wake up

Enable wake up 10 minutes when the power is switched on.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

3: Basic set value

Toggle the basic set value when the Magnet switch is opened /closed.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Open: 00, Close: FF (0)      
  Open: FF, Close: 00 (1)      

121: Reports that will be sent

configuration Value 4(LSB)

Overview

See documentation for bytes

Setting to 1 send BATTERY

Setting to 16 sends SENSOR BINARY

Setting to 17 sends SENSOR BINARY and BATTERY

Property Value      
Configuration ID config_121_4_000000FF      
Data Type INTEGER   Default Value 0
Options Do not send anything (0)      
  Send battery report (1)      
  Send Sensor Binary report (16)      
  Send Sensor Binary and Battery reports (17)      

121: Parameter 121 Value 3

See documentation

Overview

set to 1 sends BASIC SET

set to 16 sends ALARM

set to 17 sends ALARM and BASIC SET

Property Value      
Configuration ID config_121_4_0000FF00      
Data Type INTEGER   Default Value 1
Options Do not send anything (0)      
  Send Basic Set (1)      
  Send ALARM (16)      
  Send Basic Set and ALARM (17)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to