DSC06 Smart Energy Switch

This describes the Z-Wave device DSC06, manufactured by AEON Labs with the thing type UID of aeon_dsc06_00_000.

Smart Energy Switch

Channels

The following table summarises the channels available for the DSC06 Smart Energy Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC06 Smart Energy Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Multilevel Sensor Report Content  
80: Automatic Notifications Enable or disable automatic notifications
90: Enable/disable Parameter 91 and 92 Enables/disables parameter 91 and 92 below
91: Minimum change in wattage Minimum change in wattage to trigger event
92: Minimum change in wattage % Minimum change in wattage % to trigger event
101: Group 1 report  
102: Group 2 report  
103: Group 3 report  
111: Interval Group 1 The time interval (in seconds) for sending report to Group 1
112: Interval Group 2 The time interval (in seconds) for sending report to Group 2
113: Interval Group 3 The time interval (in seconds) for sending report to Group 3
254: Device Tag  
100: Set 100 to 103 to default  
110: Set 111 to 113 to default  
255: Device Reset  
1: Status Reports  

1: Multilevel Sensor Report Content

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Power (0)      
  Voltage (1)      

80: Automatic Notifications

Enable or disable automatic notifications

Overview

Enables automatic notifications to associated devices whenever there is a state change

(0=nothing, 1=hail CC, 2=basic CC report)

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Nothing (0)      
  Hail (1)      
  Basic CC Report (2)      

90: Enable/disable Parameter 91 and 92

Enables/disables parameter 91 and 92 below

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

91: Minimum change in wattage

Minimum change in wattage to trigger event

Overview

The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent.

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

92: Minimum change in wattage %

Minimum change in wattage % to trigger event

Overview

The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent.

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 10

101: Group 1 report

Property Value      
Configuration ID config_101_4      
Data Type INTEGER   Default Value 8
Options None (0)      
  Multisensor Report (2)      
  Meter Report (Watts) (4)      
  Meter Report (kWh) (8)      
  Meter Report Watts and kWh (12)      

102: Group 2 report

Property Value      
Configuration ID config_102_4      
Data Type INTEGER   Default Value 0
Options None (0)      
  Multisensor Report (2)      
  Meter Report (Watts) (4)      
  Meter Report (kWh) (8)      
  Meter Report Watts and kWh (12)      

103: Group 3 report

Property Value      
Configuration ID config_103_4      
Data Type INTEGER   Default Value 0
Options None (0)      
  Multisensor Report (2)      
  Meter Report (Watts) (4)      
  Meter Report (kWh) (8)      
  Meter Report Watts and kWh (12)      

111: Interval Group 1

The time interval (in seconds) for sending report to Group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 65535
Default Value 600

112: Interval Group 2

The time interval (in seconds) for sending report to Group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 65535
Default Value 600

113: Interval Group 3

The time interval (in seconds) for sending report to Group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 65535
Default Value 600

254: Device Tag

Property Value
Configuration ID config_254_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

100: Set 100 to 103 to default

Property Value      
Configuration ID config_100_1_wo      
Data Type INTEGER   Default Value 0
Options Reset (0)      

110: Set 111 to 113 to default

Property Value      
Configuration ID config_110_1_wo      
Data Type INTEGER   Default Value 0
Options Reset (0)      

255: Device Reset

Property Value      
Configuration ID config_255_1_wo      
Data Type INTEGER   Default Value 0
Options Reset (0)      

1: Status Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.