DSC10 Heavy Duty Smart Switch

This describes the Z-Wave device DSC10, manufactured by AEON Labs with the thing type UID of aeon_dsc10_00_000.

Heavy Duty Smart Switch

Channels

The following table summarises the channels available for the DSC10 Heavy Duty Smart Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC10 Heavy Duty Smart Switch. Detailed information on each parameter can be found below.

Parameter Description
3: Current Overload Protection See overview
20: Output Load Status Configure the output load status after re‐power on.
80: Notification on Status Change The type of report to send when the device status changes
90: Enables/disables parameter 91/92  
91: Minimum Change to send Report (Watt) The value represents the minimum change in wattage for a Report to be sent.
92: Minimum Change to send Report (%) The minimum change in wattage Percent for a report to be sent
200: Partner ID  
252: Lock/unlock Configuration Changes  
1: Group 1  
2: Group 2  

3: Current Overload Protection

See overview

Overview

Load will be closed when the Current more than 39.5A and the time more than 5 seconds.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER      
Range 0 to 1   Default Value 0
Options Activate Overload Protection (0)      
  Deactivate Overload Protection (1)      

20: Output Load Status

Configure the output load status after re‐power on.

Property Value      
Configuration ID config_20_1      
Data Type INTEGER      
Range 0 to 2   Default Value 0
Options Last Status (0)      
  Always ON (1)      
  Always OFF (2)      

80: Notification on Status Change

The type of report to send when the device status changes

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Nothing (0)      
  Hail (1)      
  Basic CC Report (2)      

90: Enables/disables parameter 91/92

Property Value      
Configuration ID config_90_1      
Data Type INTEGER      
Range 0 to 1   Default Value 0
Options Enable parameters 91 and 92 (0)      
  Disable parameters 91 and 92 (1)      

91: Minimum Change to send Report (Watt)

The value represents the minimum change in wattage for a Report to be sent.

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 32000
Default Value 50

92: Minimum Change to send Report (%)

The minimum change in wattage Percent for a report to be sent

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 10

200: Partner ID

Property Value      
Configuration ID config_200_1      
Data Type INTEGER      
Range 0 to 1   Default Value 0
Options Aeon Labs (0)      
  Other (1)      

252: Lock/unlock Configuration Changes

Property Value      
Configuration ID config_252_1      
Data Type INTEGER      
Range 0 to 1   Default Value 0
Options Unlocked (0)      
  Locked (1)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.