DSC11 Smart Strip

This describes the Z-Wave device DSC11, manufactured by AEON Labs with the thing type UID of aeon_dsc11_00_000.

Smart Strip

Overview

Update command classes -:
METER:5 :: ADD
METER:6 :: ADD

Channels

The following table summarises the channels available for the DSC11 Smart Strip.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) entire strip meter_kwh meter_kwh Energy Number
Electric meter (watts) entire strip meter_watts meter_watts Energy Number
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Switch 3 switch_binary3 switch_binary Switch Switch
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number
Switch 4 switch_binary4 switch_binary Switch Switch
Electric meter (kWh) 4 meter_kwh4 meter_kwh Energy Number
Electric meter (watts) 4 meter_watts4 meter_watts Energy Number
Switch 5 switch_binary5 switch_binary Switch Switch
Electric meter (kWh) 5 meter_kwh5 meter_kwh Energy Number
Electric meter (watts) 5 meter_watts5 meter_watts Energy Number
Switch 6 switch_binary6 switch_binary Switch Switch
Electric meter (kWh) 6 meter_kwh6 meter_kwh Energy Number
Electric meter (watts) 6 meter_watts6 meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC11 Smart Strip. Detailed information on each parameter can be found below.

Parameter Description
1: Voltage to calculate power Line voltage used for device calculations of wattage
4: Selective Reporting Enable selective reporting only when power changes
5: Wattage Threshold - Whole strip Threshold change in wattage to induce a automatic report
6: Wattage Threshold - Socket 1 Threshold change in wattage to induce a automatic report
7: Wattage Threshold - Socket 2 Threshold change in wattage to induce a automatic report
8: Wattage Threshold - Socket 3 Threshold change in wattage to induce a automatic report
9: Wattage Threshold - Socket 4 Threshold change in wattage to induce a automatic report
10: Wattage Threshold - Socket 5 Threshold change in wattage to induce a automatic report
11: Wattage Threshold - Socket 6 Threshold change in wattage to induce a automatic report
12: Percent Change - Whole Strip Percentage change in wattage to induce a automatic report
13: Percent Change - Socket 1 Percentage change in wattage to induce a automatic report
14: Percent Change - Socket 2 Percentage change in wattage to induce a automatic report
15: Percent Change - Socket 3 Percentage change in wattage to induce a automatic report
16: Percent Change - Socket 4 Percentage change in wattage to induce a automatic report
17: Percent Change - Socket 5 Percentage change in wattage to induce a automatic report
18: Percent Change - Socket 6 Percentage change in wattage to induce a automatic report
80: Status of load changed report Status of load changed,send group 1
90: Get Temperature Get temperature of Smart Strip
100: Reset 0x65~0x67 to default value Reset 0x65~0x67 to default value
101: select channels to report consumtion as item 1 A binary field for reporting consumption (kWh) of channels
101: Select channels to report power as item 1 A binary field to choose channels to report power
102: Item 2 (kWh) Channel(s) to auto-report kWh
102: Item 2 (power) Channel(s) to auto-report wattage
111: Interval to send out reports of Group 1  
112: Interval to send out reports of Group 2  
113: Interval to send out reports of Group 3  
1: Group 1  

1: Voltage to calculate power

Line voltage used for device calculations of wattage

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 32000
Default Value 120

4: Selective Reporting

Enable selective reporting only when power changes

Overview

Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic.           

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 16
Default Value 1

5: Wattage Threshold - Whole strip

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000)           

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

6: Wattage Threshold - Socket 1

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Socket 1). (Valid values 0-60000)           

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

7: Wattage Threshold - Socket 2

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Socket 2). (Valid values 0-60000)           

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

8: Wattage Threshold - Socket 3

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Socket 3). (Valid values 0-60000)           

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

9: Wattage Threshold - Socket 4

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Socket 4). (Valid values 0-60000)           

Property Value
Configuration ID config_9_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

10: Wattage Threshold - Socket 5

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Socket 5). (Valid values 0-60000)           

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

11: Wattage Threshold - Socket 6

Threshold change in wattage to induce a automatic report

Overview

Threshold change in wattage to induce a automatic report (Socket 6). (Valid values 0-60000)           

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

12: Percent Change - Whole Strip

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Whole Smart Strip). (Valid values 0-100)           

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 100
Default Value 5

13: Percent Change - Socket 1

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Socket 1). (Valid values 0-100)           

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 0 to 100
Default Value 5

14: Percent Change - Socket 2

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Socket 2). (Valid values 0-100)           

Property Value
Configuration ID config_14_1
Data Type INTEGER
Range 0 to 100
Default Value 5

15: Percent Change - Socket 3

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Socket 3). (Valid values 0-100)           

Property Value
Configuration ID config_15_1
Data Type INTEGER
Range 0 to 100
Default Value 5

16: Percent Change - Socket 4

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Socket 4). (Valid values 0-100)           

Property Value
Configuration ID config_16_1
Data Type INTEGER
Range 0 to 100
Default Value 5

17: Percent Change - Socket 5

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Socket 5). (Valid values 0-100)           

Property Value
Configuration ID config_17_1
Data Type INTEGER
Range 0 to 100
Default Value 5

18: Percent Change - Socket 6

Percentage change in wattage to induce a automatic report

Overview

Percentage change in wattage to induce a automatic report (Socket 6). (Valid values 0-100)           

Property Value
Configuration ID config_18_1
Data Type INTEGER
Range 0 to 100
Default Value 5

80: Status of load changed report

Status of load changed,send group 1

Overview

Status of load changed,send group 1 associate nodes Hail CC or Basic report CC.           

Property Value      
Configuration ID config_80_4      
Data Type INTEGER   Default Value 8
Options Not sent (0)      
  Send Hail (1)      
  Send Basic (2)      

90: Get Temperature

Get temperature of Smart Strip

Overview

Get temperature of Smart Strip (Only GET is valid)

Property Value
Configuration ID config_90_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

100: Reset 0x65~0x67 to default value

Reset 0x65~0x67 to default value

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 0
Options Reset (0)      

101: select channels to report consumtion as item 1

A binary field for reporting consumption (kWh) of channels

Overview

Choose the channel or channels to auto-report kWh based on a time interval set in parameter 111.  This is the LSB

 1 - report only a summary of all channels ( bit 1)

 2 - report channel 1 wattage (bit 2)

 3 - report a summary of all channels and channel 1 (bits 1 and 2)

 4 - report channel 2 wattage

<…>

14 - channel 3, channel 2, and channel 1

 15 - channel 3, channel 2, channel 1, and summary

 etc.

 127 - in the end is reporting values for each individual channel (1-6) and the summary data.  In binary, bits 1 through 7 set to 1.

 The bit values are as follows:

 1 - summary report

2 - channel 1 report

4 - channel 2 report

8 - channel 3 report

16 - channel 4 report

32 - channel 5 report

64 - channel 6 report

Property Value
Configuration ID config_101_4_000000FF
Data Type INTEGER
Range 0 to 255
Default Value 0

101: Select channels to report power as item 1

A binary field to choose channels to report power

Overview

Choose the channel or channels to auto-report wattage based on a time interval set in parameter 111. 

 examples:

 1 - report only a summary of all channels ( bit 1)

 2 - report channel 1 wattage (bit 2)

 3 - report a summary of all channels and channel 1 (bits 1 and 2)

 4 - report channel 2 wattage

<…>

14 - channel 3, channel 2, and channel 1

 15 - channel 3, channel 2, channel 1, and summary

 etc.

 127 - in the end is reporting values for each individual channel (1-6) and the summary data.  In binary, bits 1 through 7 set to 1.

 The bit values are as follows:

 1 - summary report

2 - channel 1 report

4 - channel 2 report

8 - channel 3 report

16 - channel 4 report

32 - channel 5 report

64 - channel 6 report

Property Value
Configuration ID config_101_4_0000FF00
Data Type INTEGER
Range 0 to 255
Default Value 0

102: Item 2 (kWh)

Channel(s) to auto-report kWh

Overview

Choose the channel or channels to auto-report kWh based on a time interval set in parameter 112.  This is the LSB

 1 - report only a summary of all channels ( bit 1)

 2 - report channel 1 wattage (bit 2)

 3 - report a summary of all channels and channel 1 (bits 1 and 2)

 4 - report channel 2 wattage

<…>

14 - channel 3, channel 2, and channel 1

 15 - channel 3, channel 2, channel 1, and summary

 etc.

 127 - in the end is reporting values for each individual channel (1-6) and the summary data.  In binary, bits 1 through 7 set to 1.

 The bit values are as follows:

 1 - summary report

2 - channel 1 report

4 - channel 2 report

8 - channel 3 report

16 - channel 4 report

32 - channel 5 report

64 - channel 6 report

Property Value
Configuration ID config_102_4_000000FF
Data Type INTEGER
Range 0 to 255
Default Value 0

102: Item 2 (power)

Channel(s) to auto-report wattage

Overview

Choose the channel or channels to auto-report wattage based on a time interval set in parameter 112. 

 examples:

 1 - report only a summary of all channels ( bit 1)

 2 - report channel 1 wattage (bit 2)

 3 - report a summary of all channels and channel 1 (bits 1 and 2)

 4 - report channel 2 wattage

<…>

14 - channel 3, channel 2, and channel 1

 15 - channel 3, channel 2, channel 1, and summary

 etc.

 127 - in the end is reporting values for each individual channel (1-6) and the summary data.  In binary, bits 1 through 7 set to 1.

 The bit values are as follows:

 1 - summary report

2 - channel 1 report

4 - channel 2 report

8 - channel 3 report

16 - channel 4 report

32 - channel 5 report

64 - channel 6 report

Property Value
Configuration ID config_102_4_0000FF00
Data Type INTEGER
Range 0 to 255
Default Value 0

111: Interval to send out reports of Group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

112: Interval to send out reports of Group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

113: Interval to send out reports of Group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.