DSC12 Micro Smart Energy Switch

This describes the Z-Wave device DSC12, manufactured by AEON Labs with the thing type UID of aeon_dsc12_00_000.

Micro Smart Energy Switch

Channels

The following table summarises the channels available for the DSC12 Micro Smart Energy Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC12 Micro Smart Energy Switch. Detailed information on each parameter can be found below.

Parameter Description
2: Make Micro Smart Switch Blink  
3: Current Overload Protection  
80: Notification on Status Change  
90: Automated sending of a Report triggered by minimal change of value.  
91: Minimum Change to send Report (Watt)  
92: Minimum Change to send Report (%)  
101: Which reports need to send automatically in timing intervals for group 1  
102: Which reports need to send automatically in timing intervals for group 2  
103: Which reports need to send automatically in timing intervals for group 3  
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
120: Turn External Button Mode  
1: Target for automatic meter reports  
2: Target for automatic reports  
Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Current Overload Protection

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Activate (1)      

80: Notification on Status Change

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Hail CC Sent (1)      
  Basic CC Report Sent (2)      

90: Automated sending of a Report triggered by minimal change of value.

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Deavtivate (0)      
  Activate (1)      

91: Minimum Change to send Report (Watt)

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 65535
Default Value 25

92: Minimum Change to send Report (%)

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 255
Default Value 5

101: Which reports need to send automatically in timing intervals for group 1

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

102: Which reports need to send automatically in timing intervals for group 2

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 8

103: Which reports need to send automatically in timing intervals for group 3

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 3

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

120: Turn External Button Mode

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 255
Options Momentary Button Mode (0)      
  2 State Switch Mode (1)      
  3 Way Switch Mode (2)      

1: Target for automatic meter reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Target for automatic reports

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.