DSC13 Micro Smart Energy Illuminator
This describes the Z-Wave device DSC13, manufactured by AEON Labs with the thing type UID of aeon_dsc13_00_000
.
Micro Smart Energy Illuminator
Channels
The following table summarises the channels available for the DSC13 Micro Smart Energy Illuminator.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (power) | sensor_power | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Dimmer
Restore Last Value
Restore Last Dimming level on ON.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_restoreLastValue | |||
Data Type | BOOLEAN | Default Value | true | |
Options | Restore Last Value (true) | |||
Restore Full Brightness (false) |
Device Configuration
The following table provides a summary of the configuration parameters available in the DSC13 Micro Smart Energy Illuminator. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
1: Type of Sensor Report | Defines the value type to be sent as Sensor Report. |
2: Blinking Behavior | See overview |
80: Notification on Status Change | Type of report to send when the device status changes |
90: Disable Minimum Change report | |
91: Minimum Change to send Report (Watt) | The minimum change in Wattage for a Report to be sent |
92: Minimum Change to send Report (%) | The minimum change in Wattage Percent for a report to be sent |
101: Reports to send to Group 1 | See overview |
102: Reports to send to Group 2 | See overview |
103: Reports to send to Group 3 | See overview |
111: Interval to send out reports of group 1 | Time interval to send report to Group 1 |
112: Interval to send out reports of group 2 | Time interval to send report to Group 2 |
113: Interval to send out reports of group 3 | Time interval to send report to Group 3 |
1: Group 1 | Status Reports |
2: Group 2 | |
3: Group 3 |
1: Type of Sensor Report
Defines the value type to be sent as Sensor Report.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_1_1 | |||
Data Type | INTEGER | |||
Range | 0 to 1 | Default Value | 0 | |
Options | Power (0) | |||
Voltage (1) |
2: Blinking Behavior
See overview
Overview
The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.
Property | Value |
---|---|
Configuration ID | config_2_2 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 0 |
80: Notification on Status Change
Type of report to send when the device status changes
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_80_1 | |||
Data Type | INTEGER | |||
Range | 0 to 2 | Default Value | 0 | |
Options | Nothing (0) | |||
Hail (1) | ||||
Basic CC Report (2) |
90: Disable Minimum Change report
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_90_1 | |||
Data Type | INTEGER | |||
Range | 0 to 1 | Default Value | 0 | |
Options | Disabled (0) | |||
Enabled (1) |
91: Minimum Change to send Report (Watt)
The minimum change in Wattage for a Report to be sent
Property | Value |
---|---|
Configuration ID | config_91_2 |
Data Type | INTEGER |
Range | 0 to 32000 |
Default Value | 50 |
92: Minimum Change to send Report (%)
The minimum change in Wattage Percent for a report to be sent
Property | Value |
---|---|
Configuration ID | config_92_1 |
Data Type | INTEGER |
Range | 0 to 100 |
Default Value | 10 |
101: Reports to send to Group 1
See overview
Overview
The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1.
Property | Value |
---|---|
Configuration ID | config_101_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 4 |
102: Reports to send to Group 2
See overview
Overview
The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1.
Property | Value |
---|---|
Configuration ID | config_102_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 4 |
103: Reports to send to Group 3
See overview
Overview
The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1.
Property | Value |
---|---|
Configuration ID | config_103_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 4 |
111: Interval to send out reports of group 1
Time interval to send report to Group 1
Property | Value |
---|---|
Configuration ID | config_111_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 720 |
112: Interval to send out reports of group 2
Time interval to send report to Group 2
Property | Value |
---|---|
Configuration ID | config_112_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 720 |
113: Interval to send out reports of group 3
Time interval to send report to Group 3
Property | Value |
---|---|
Configuration ID | config_113_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 720 |
1: Group 1
Status Reports
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
2: Group 2
Property | Value |
---|---|
Configuration ID | group_2 |
Data Type | TEXT |
Range | to |
3: Group 3
Property | Value |
---|---|
Configuration ID | group_3 |
Data Type | TEXT |
Range | to |