DSC14 Micro Motor Controller

This describes the Z-Wave device DSC14, manufactured by AEON Labs with the thing type UID of aeon_dsc14_00_000.

Micro Motor Controller

Channels

The following table summarises the channels available for the DSC14 Micro Motor Controller.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC14 Micro Motor Controller. Detailed information on each parameter can be found below.

Parameter Description
1: Type of Sensor Report  
2: Blinking Behavior  
80: Notification on Status Change  
90: Disable automated reporting  
91: Minimum Change to send Report (Watt)  
92: Minimum Change to send Report (%)  
101: reports to send automatically  
102: Which reports to send automatically to group 2  
103: Which reports to send automatically to group 3  
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
1: Group 1 Status Reports

1: Type of Sensor Report

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Power (0)      
  Voltage (1)      

2: Blinking Behavior

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

80: Notification on Status Change

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Nothing (0)      
  Hail (1)      
  Basic CC Report (2)      

90: Disable automated reporting

Overview

Disables Function of automated sending of a Report triggered by minimal change of value.

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

91: Minimum Change to send Report (Watt)

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 32000
Default Value 50

92: Minimum Change to send Report (%)

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 10

101: reports to send automatically

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

102: Which reports to send automatically to group 2

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

103: Which reports to send automatically to group 3

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 0 to 65535
Default Value 720

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 0 to 65535
Default Value 720

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 0 to 65535
Default Value 720

1: Group 1

Status Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to