DSC17 Micro Double Smart Switch

This describes the Z-Wave device DSC17, manufactured by AEON Labs with the thing type UID of aeon_dsc17_00_000.

Micro Double Smart Switch

Channels

The following table summarises the channels available for the DSC17 Micro Double Smart Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Reset Meter meter_reset meter_reset Energy Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC17 Micro Double Smart Switch. Detailed information on each parameter can be found below.

Parameter Description
2: Blink This is a double byte value.
3: Current Overload Protection Load current>=10.A,2 minutes later ,automatic turn off the load
80: Notification on Status Change Enables automatic notifications to associated devices
90: Enables/disables parameter 91 and 92 Automated sending of a Report triggered by minimal change of value.
91: Minimum Change to send Report (Watt) The value represents the minimum change in Watts for a Report to be sent
92: Minimum Change to send Report (%) The value represents the min. change in Watts Percent for a report to be sent
101: Automatic reports for group 1 Which reports need to send automatically in timing intervals for group 1
102: Automatic reports for group 2 Which reports need to send automatically in timing intervals for group 2
103: Automatic reports for group 3 Which reports need to send automatically in timing intervals for group 3
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
120: Set External Switch/Button Control mode  
255: Reset to the default Configuration.  
100: Set 101-103 to default.  
110: Set 111-113 to default.  
1: Group 1  
2: Group 2  
3: Group 3  

This is a double byte value.

Overview

This is a double byte value. The LSB defines the total time the device need to blink. The value is set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.

Configuration Value 1 is to Specify the time that Micro Double SES need blink, The unit is Second; Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. For example: if we set Configuration Value 1 to ‘15’,Configuration Value 2 to ‘10’,then Micro Double SES will open 0.5 second, close 0.5 second, and repeat for 14 times. 

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Current Overload Protection

Load current>=10.A,2 minutes later ,automatic turn off the load

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

80: Notification on Status Change

Enables automatic notifications to associated devices

Overview

Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Switch’s load changed

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options nothing (0)      
  Hail CC Sent (1)      
  Basic CC Report Sent (2)      

90: Enables/disables parameter 91 and 92

Automated sending of a Report triggered by minimal change of value.

Overview

Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value.

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Deavtivate (0)      
  Activate (1)      

91: Minimum Change to send Report (Watt)

The value represents the minimum change in Watts for a Report to be sent

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

92: Minimum Change to send Report (%)

The value represents the min. change in Watts Percent for a report to be sent

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 10

101: Automatic reports for group 1

Which reports need to send automatically in timing intervals for group 1

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value      
Configuration ID config_101_4      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options Disabled (0)      
  Voltage (1)      
  Current (2)      
  Wattage (4)      
  kWh (8)      
  All Values (15)      

102: Automatic reports for group 2

Which reports need to send automatically in timing intervals for group 2

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value      
Configuration ID config_102_4      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options Disabled (0)      
  Voltage (1)      
  Current (2)      
  Wattage (4)      
  kWh (8)      
  All Values (15)      

103: Automatic reports for group 3

Which reports need to send automatically in timing intervals for group 3

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value      
Configuration ID config_103_4      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options Disabled (0)      
  Voltage (1)      
  Current (2)      
  Wattage (4)      
  kWh (8)      
  All Values (15)      

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

120: Set External Switch/Button Control mode

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 255
Options Momentary button mode (0)      
  2-state switch mode (1)      
  Unidentified mode (255)      

255: Reset to the default Configuration.

Property Value      
Configuration ID config_255_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

100: Set 101-103 to default.

Property Value      
Configuration ID config_100_1_wo      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

110: Set 111-113 to default.

Property Value      
Configuration ID config_110_1_wo      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to