DSC19 Micro Smart Energy Illuminator G2

This describes the Z-Wave device DSC19, manufactured by AEON Labs with the thing type UID of aeon_dsc19_00_000.

Micro Smart Energy Illuminator G2

Overview

The Aeon Labs Micro Smart Dimmer (2nd Edition) is a scene multilevel switch device based on Z‐wave enhanced slave library V4.55.00.

Inclusion Information

Include Smart Dimmer into an existing Z‐Wave network: 1. Install Micro Smart Dimmer, and connect Micro Smart Dimmer to an AC‐input power source. 2. Let the primary controller of existing Z‐Wave network into inclusion mode (If you don’t know how to do this, refer to its manual). 3. Press the Z‐Wave button. 4. If the Learning failed, please repeat the process from step 2.

Exclusion Information

Remove Smart Switch from an existing Z‐Wave network: 1. Installed Micro Smart Dimmer, and connect Micro Smart Dimmer to an AC‐ input power source. 2. Let the primary controller of existing Z‐Wave network into remove mode (If you don’t know how to do this, refer to its manual). 3. Press the Z‐Wave button. 4. If the remove failed, please repeat the process from step 2

Channels

The following table summarises the channels available for the DSC19 Micro Smart Energy Illuminator G2.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric Meter (kVah) meter_kvah meter_kvah Energy Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC19 Micro Smart Energy Illuminator G2. Detailed information on each parameter can be found below.

Parameter Description
2: Make Micro Smart Dimmer 2nd Edition Blink The LSB defines the total time the device need to blink.
3: Current Overload Protection Load will be closed when current more that 2.7A and time more than 2 minutes
13: Enable/Disable CRC16 encapsulation Parameter to Enable/Disable CRC16 encapsulation
80: Notification on Status Change Send load notification to associated devices
90: Sending of a Report triggered by minimal change of value. Automated sending of a Report triggered by minimal change of value.
91: Minimum Change to send Report (Watt) The value represents the minimum change in Wattage for a Report to be sent.
92: Minimum Change to send Report (%) The minimum change in Watage Percent for a report to be sent.
101: Reports for Group 1 Which reports need to send automatically in timing intervals for group 1
102: Reports for Group 2 Which reports need to send automatically in timing intervals for group 2
103: Reports for Group 3 Which reports need to send automatically in timing intervals for group 3
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
120: Turn External Button Mode Parameter to set External button type
1: Target for automatic meter reports  
2: Target for automatic reports  

The LSB defines the total time the device need to blink.

Overview

This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Current Overload Protection

Load will be closed when current more that 2.7A and time more than 2 minutes

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Activate (1)      

13: Enable/Disable CRC16 encapsulation

Parameter to Enable/Disable CRC16 encapsulation

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 0 to 255
Default Value 0

80: Notification on Status Change

Send load notification to associated devices

Overview

Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Dimmer’s load changed

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Hail CC Sent (1)      
  Basic CC Report Sent (2)      

90: Sending of a Report triggered by minimal change of value.

Automated sending of a Report triggered by minimal change of value.

Overview

Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value.

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Deavtivate (0)      
  Activate (1)      

91: Minimum Change to send Report (Watt)

The value represents the minimum change in Wattage for a Report to be sent.

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 65535
Default Value 25

92: Minimum Change to send Report (%)

The minimum change in Watage Percent for a report to be sent.

Overview

The value represents the minimum change in Watage Percent for a report to be sent.

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 255
Default Value 5

101: Reports for Group 1

Which reports need to send automatically in timing intervals for group 1

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

102: Reports for Group 2

Which reports need to send automatically in timing intervals for group 2

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 8

103: Reports for Group 3

Which reports need to send automatically in timing intervals for group 3

Overview

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 3

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

120: Turn External Button Mode

Parameter to set External button type

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 255
Options Momentary Button Mode (0)      
  2 State Switch Mode (1)      
  3 Way Switch Mode (2)      

1: Target for automatic meter reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Target for automatic reports

Overview

According to the info in de nodeXX.xml file, this group doesn’t exist for this device. - It doesn’t work.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.