DSC24 Smart Energy Switch G2

This describes the Z-Wave device DSC24, manufactured by AEON Labs with the thing type UID of aeon_dsc24_00_000.

Smart Energy Switch G2

Channels

The following table summarises the channels available for the DSC24 Smart Energy Switch G2.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Reset Meter meter_reset meter_reset Energy Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC24 Smart Energy Switch G2. Detailed information on each parameter can be found below.

Parameter Description
1: Multilevel Sensor Report Content  
2: Make SES blink  
80: Automatic Notifications Enables automatic notifications to associated devices whenever there is a state change
90: Enable Parameter 91 Enables/disables parameter 91 and 92 below
91: Minimum change in wattage The value here represents minimum change in wattage (in terms of wattage) for a REPORT to …
92: Minimum change in wattage % The value here represents minimum change in wattage percent (in terms of percentage) for a…
100: Set 100 to 103 to default  
101: Group 1 report  
102: Group 2 report  
103: Group 3 report  
110: Set 111 to 113 to default  
111: Interval group 1 The time interval of sending Report group 1
112: Interval group 1 The time interval of sending Report group 2
113: Interval group 1 The time interval of sending Report group 3
254: Device Tag  
255: Device Reset  
1: Status Reports  
2: Send Reports on blind state change Send Reports on blind state change

1: Multilevel Sensor Report Content

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0
Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

80: Automatic Notifications

Enables automatic notifications to associated devices whenever there is a state change

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Nothing (0)      
  Hail (1)      
  Basic CC Report (2)      

90: Enable Parameter 91

Enables/disables parameter 91 and 92 below

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

91: Minimum change in wattage

The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent.

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

92: Minimum change in wattage %

The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent.

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 255
Default Value 10

100: Set 100 to 103 to default

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 0
Options Reset (0)      

101: Group 1 report

Property Value      
Configuration ID config_101_4      
Data Type INTEGER   Default Value 8
Options Multisensor Report (2)      
  Meter Report (Watts) (4)      
  Meter Report (kWh) (8)      

102: Group 2 report

Property Value      
Configuration ID config_102_4      
Data Type INTEGER   Default Value 0
Options Multisensor Report (2)      
  Meter Report (Watts) (4)      
  Meter Report (kWh) (8)      

103: Group 3 report

Property Value      
Configuration ID config_103_4      
Data Type INTEGER   Default Value 0
Options Multisensor Report (2)      
  Meter Report (Watts) (4)      
  Meter Report (kWh) (8)      

110: Set 111 to 113 to default

Property Value      
Configuration ID config_110_1      
Data Type INTEGER   Default Value 0
Options Reset (0)      

111: Interval group 1

The time interval of sending Report group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 0 to 65535
Default Value 600

112: Interval group 1

The time interval of sending Report group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 0 to 65535
Default Value 600

113: Interval group 1

The time interval of sending Report group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 0 to 65535
Default Value 600

254: Device Tag

Property Value
Configuration ID config_254_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

255: Device Reset

Property Value      
Configuration ID config_255_1      
Data Type INTEGER   Default Value 0
Options Reset (0)      

1: Status Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Send Reports on blind state change

Send Reports on blind state change

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.