DSC26 Micro Switch G2

This describes the Z-Wave device DSC26, manufactured by AEON Labs with the thing type UID of aeon_dsc26_00_000.

Micro Switch G2

Channels

The following table summarises the channels available for the DSC26 Micro Switch G2.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the DSC26 Micro Switch G2. Detailed information on each parameter can be found below.

Parameter Description
2: Make Micro Switch 2nd Edition Blink This is a double byte value. The LSB defines the total time the device need to blink. The …
80: Notification on Status Change Parameter to Enable to send notification to associated devices (Group 1) when the state of…
101: Which reports need to send automatically in timing intervals for group 1 The value is a combination number made up of the sum of the values for the individual para…
102: Which reports need to send automatically in timing intervals for group 2 The value is a combination number made up of the sum of the values for the individual para…
103: Which reports need to send automatically in timing intervals for group 3 The value is a combination number made up of the sum of the values for the individual para…
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
120: Turn External Button Mode Parameter to set External button type
200: Partner ID  
252: Enable/disable Lock Configuration  
254: Device Tag  
255: Reset configuration set up to default setting  
1: Lifeline  
2: Retransmit  

This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

80: Notification on Status Change

Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Switch’s load changed

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Hail CC Sent (1)      
  Basic CC Report Sent (2)      

101: Which reports need to send automatically in timing intervals for group 1

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

102: Which reports need to send automatically in timing intervals for group 2

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 8

103: Which reports need to send automatically in timing intervals for group 3

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 3

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

120: Turn External Button Mode

Parameter to set External button type

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 255
Options Momentary Button Mode (0)      
  2 State Switch Mode (1)      
  3 Way Switch Mode (2)      

200: Partner ID

Property Value      
Configuration ID config_200_1      
Data Type INTEGER   Default Value 0
Options Aeon Labs Standard Product (0)      
  AT&T (1)      

252: Enable/disable Lock Configuration

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

254: Device Tag

Property Value
Configuration ID config_254_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

255: Reset configuration set up to default setting

Property Value
Configuration ID config_255_1_wo
Data Type INTEGER
Range to
Default Value 5

1: Lifeline

Overview

The Node IDs in Group 1 will receive Hail Command /Basic report (configurable) when the state of Micro Switch’s load changed.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Retransmit

Overview

When the Micro Switch receives the following commands, it will forward the commands to
all node IDs which are in Group 2.
Commands: Basic Set, Switch Binary Set, Scene Activation Set.

Property Value
Configuration ID group_2
Data Type TEXT
Range to