DSD31 Outlet Plugable Siren

This describes the Z-Wave device DSD31, manufactured by AEON Labs with the thing type UID of aeon_dsd31_00_000.

Outlet Plugable Siren

Channels

The following table summarises the channels available for the DSD31 Outlet Plugable Siren.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the DSD31 Outlet Plugable Siren. Detailed information on each parameter can be found below.

Parameter Description
37: Sirensound and Volume Sets the sound type and volume
37: Siren Sound  
37: Siren Volume  
80: Send Notifications send notifications to associated devices
252: Enable/Disable 'Lock' - Configuration  
1: Lifeline  

37: Sirensound and Volume

Sets the sound type and volume

Overview

The Value1(low byte) is used to select the Siren sound. The Value2(high byte) is used to adjust the volume. Other values will be ignored. 0 1  ->   do not change the current sound.1 1  ->   Siren sound 1 is selected.2 1  ->   Siren sound 2 i

Property Value
Configuration ID config_37_2
Data Type INTEGER
Range 0 to 65535
Default Value 13

37: Siren Sound

Property Value      
Configuration ID config_37_2_0000000F      
Data Type INTEGER   Default Value 1
Options Siren Sound 1 (1)      
  Siren Sound 2 (2)      
  Siren Sound 3 (3)      
  Siren Sound 4 (4)      
  Siren Sound 5 (5)      

37: Siren Volume

Property Value      
Configuration ID config_37_2_00000F00      
Data Type INTEGER   Default Value 3
Options 88dB (1)      
  100dB (2)      
  105dB (3)      

80: Send Notifications

send notifications to associated devices

Overview

Enable to send notifications to associated devices when the state of Siren changed.

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Nothing (0)      
  Hail CC (1)      
  Basic CC Report (2)      

252: Enable/Disable 'Lock' - Configuration

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.