ZW062 Aeon Labs Garage Door Controller Gen5

This describes the Z-Wave device ZW062, manufactured by AEON Labs with the thing type UID of aeon_zw062_00_000.

Aeon Labs Garage Door Controller Gen5

Overview

Aeon Labs Garage Door Controller is a smart and wireless Garage Door Control system, you can control the garage door to open, close, or stop moving via wireless signal on your gateway client or phone application.

The Garage Door Controller allows you to configure different alarm sounds to indicate the door ’s action.

Each action alarm sound can be customized. To change or update new alarm sounds for the Garage Door Controller, connect the Garage Door Controller to your PC host with a USB cable and download your sound files to the flash memory (128 MB) of the Garage Door Controller.

It can be included and operated in any Z-wave network with other Z-wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

It is also a security Z-wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.

Inclusion Information

Add Garage Door Controller into Z-Wave Network:

  1. Install Garage Door Controller, and connect it to the 5V DC Adapter.
  2. Let the primary controller into inclusion mode (If you don’t know how to do this, please refer to its manual).
  3. Press the Z-Wave Button.

Exclusion Information

Remove Garage Door Controller from Z-Wave Network:

  1. Install Garage Door Controller, and connect it to the 5V DC Adapter.
  2. Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual).
  3. Press the Z-Wave Button.
  4. If the remove is failed, please repeat the process from step 2.

Note: If Garage Door Controller is removed from Z-wave network, it will be reset to factory default.

Channels

The following table summarises the channels available for the ZW062 Aeon Labs Garage Door Controller Gen5.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Barrier State barrier_state barrier_state Door Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW062 Aeon Labs Garage Door Controller Gen5. Detailed information on each parameter can be found below.

Parameter Description
32: Startup ringtone Configure the default startup ringtone
35: Calibration timout Set the timeout of all calibration steps for the Sensor.
36: Number of alarm musics Get the number of alarm musics
37: Disable opening alarm Disable opening alarm
37: Opening alarm volume Opening alarm volume
37: Opening alarm choice Alarm mode when the garage door is opening
37: Opening alarm LED mode Opening alarm LED mode
38: Disable closing alarm Disable closing alarm
38: Closing alarm volume Closing alarm volume
38: Closing alarm choice Alarm mode when the garage door is closing
38: Closing alarm LED mode Closing alarm LED mode
39: Unknown state alarm mode Configuration alarm mode when the garage door is in “unknown” state
40: Closed alarm mode Configure the alarm mode when the garage door is in closed position.
41: Tamper switch configuration Configuration report for the tamper switch State
45: Temperature Get the environment temperature
47: Button definition Define the function of Button- or Button+.
80: Door state change report type Configure the door state change report type
241: Pair the Sensor Pair the Sensor with Garage Door Controller
252: Lock Configuration Enable/disable configuration
34: Sensor Calibration Perform Sensor Calibration
42: Battery state Configuration report for the battery state of Sensor
43: Play or Pause ringtone Start playing or Stop playing the ringtone
44: Ringtone test volume Set volume for test of ringtone
1: Group 1 Position status changed
2: Group 2 Forward the Basic Set

32: Startup ringtone

Configure the default startup ringtone

Overview

Configure the default startup ringtone.

Value=0, disable the Startup ringtone.
Value=others, Enable and select a startup ringtone for the Garage Door Controller.

Property Value
Configuration ID config_32_1
Data Type INTEGER
Range 1 to 100
Default Value 1

35: Calibration timout

Set the timeout of all calibration steps for the Sensor.

Overview

Set the timeout of all calibration steps for the Sensor.

Property Value
Configuration ID config_35_2
Data Type INTEGER
Range 1 to 255
Default Value 60

36: Number of alarm musics

Get the number of alarm musics

Overview

Get the numbers of alarm music.

Property Value
Configuration ID config_36_1
Data Type INTEGER
Range 1 to 100
Default Value 1

37: Disable opening alarm

Disable opening alarm

Overview

Configure the alarm mode when the garage door is opening.

Value4=0, disable the alarm prompt.
Value4=1, enable the alarm prompt.

Property Value      
Configuration ID config_37_4_000000FF      
Data Type INTEGER   Default Value 1
Options Disable alarm prompt (0)      
  Enable alarm prompt (1)      

37: Opening alarm volume

Opening alarm volume

Overview

Configure the alarm mode when the garage door is opening.

Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels).

Property Value
Configuration ID config_37_4_0000FF00
Data Type INTEGER
Range 1 to 10
Default Value 8

37: Opening alarm choice

Alarm mode when the garage door is opening

Overview

Configure the alarm mode when the garage door is opening.

Value2: configure the alarm sound (there are 4 types sound saved in EEPROM and user also can update it).

Property Value
Configuration ID config_37_4_00FF0000
Data Type INTEGER
Range 1 to 4
Default Value 1

37: Opening alarm LED mode

Opening alarm LED mode

Overview

Configure the alarm mode when the garage door is opening.

Value1: configure the frequency of blinking for the Alarm LED , there are 10 levels from 1 to 10, the minimum frequency is level 1 and the max frequency is level 10.

Property Value
Configuration ID config_37_4_0F000000
Data Type INTEGER
Range 1 to 10
Default Value 10

38: Disable closing alarm

Disable closing alarm

Overview

Configure the alarm mode when the garage door is closing.

Value4=0, disable the alarm prompt.
Value4=1, enable the alarm prompt.

Property Value      
Configuration ID config_38_4_000000FF      
Data Type INTEGER   Default Value 1
Options Disable alarm prompt (0)      
  Enable alarm prompt (1)      

38: Closing alarm volume

Closing alarm volume

Overview

Configure the alarm mode when the garage door is closing.

Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels).

Property Value
Configuration ID config_38_4_0000FF00
Data Type INTEGER
Range 1 to 10
Default Value 8

38: Closing alarm choice

Alarm mode when the garage door is closing

Overview

Configure the alarm mode when the garage door is closing.

Value2: configure the alarm sound (there are 4 types sound saved in EEPROM and user also can update it).

Property Value
Configuration ID config_38_4_00FF0000
Data Type INTEGER
Range 1 to 4
Default Value 2

38: Closing alarm LED mode

Closing alarm LED mode

Overview

Configure the alarm mode when the garage door is closing.

Value1: configure the frequency of blinking for the Alarm LED , there are 10 levels from 1 to 10, the minimum frequency is level 1 and the max frequency is level 10.

Property Value
Configuration ID config_38_4_0F000000
Data Type INTEGER
Range 1 to 10
Default Value 6

39: Unknown state alarm mode

Configuration alarm mode when the garage door is in “unknown” state

Overview

Configuration alarm mode when the garage door is in
“unknown” state:
1, Value1: configure the frequency of blinking for the Alarm
LED , there are 10 levels that 1 to10 level, the minimum
frequency is level 1 and the max frequency is level 10.
2, Value2: configure the alarm sound (there are 4 types sound
saved in EEPROM and user also can update it).
3, Value3: configure the volume of alarm sound (there are 10
levels, the min volume is 1 level and the max volume is 10

levels).
4, Value4=0, disable the alarm prompt. Value4=1, enable the
alarm prompt.

default values:

Value1=4
Value2=3
Value3=8
Value4=0

Property Value
Configuration ID config_39_4
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

40: Closed alarm mode

Configure the alarm mode when the garage door is in closed position.

Overview

Configuration alarm mode when the garage door is in
“closed” state:
1, Value1: configure the frequency of blinking for the Alarm
LED , there are 10 levels that 1 to10 level, the minimum
frequency is level 1 and the max frequency is level 10.
2, Value2: configure the alarm sound (there are 4 types sound
saved in EEPROM and user also can update it).
3, Value3: configure the volume of alarm sound (there are 10
levels, the min volume is 1 level and the max volume is 10 levels).
4, Value4=0, disable the alarm prompt. Value4=1, enable the
alarm prompt.

default values:

Value1=2
Value2=4
Value3=8
Value4=0

Property Value
Configuration ID config_40_4
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

41: Tamper switch configuration

Configuration report for the tamper switch State

Overview

Configuration report for the tamper switch state:
1, Value=0x00: Sensor is not removed
2, Value=0x0F: Sensor is removed

Note:

  1. The Garage Door Controller will send this configuration report to gateway controller or associated nodes automatically if the Sensor is removed.
  2. You can send the value=0x55555555 of this parameter to controller to relieve the alarm state.
Property Value
Configuration ID config_41_1
Data Type INTEGER
Range 0 to 255
Default Value 0

45: Temperature

Get the environment temperature

Overview

Get the environment temperature:
The temperature value contains one decimal point. E.g. If the report value=252, the temperature is 25.2 °C .
Range is 0 to 500 (0 to 50.0 °C ).

Property Value
Configuration ID config_45_2
Data Type INTEGER
Range 0 to 500
Default Value 0

47: Button definition

Define the function of Button- or Button+.

Overview

Define the function of Button- or Button+.
Value=0, short pressing the “Button +/-” will be used to adjust the volume of sound. Long pressing the “Button +/-” will be used to switch the sound to the next.
Value=1, short pressing the “Button +/-” will be used to switch the sound to the next. Long pressing the “Button +/-” will be used to adjust the volume of sound.

Property Value      
Configuration ID config_47_1      
Data Type INTEGER   Default Value 0
Options Mode 0 (0)      
  Mode 1 (1)      

80: Door state change report type

Configure the door state change report type

Overview

It will send the Hail CC/configuration report CC when the state of garage door is changed:

1, Value=0 , reserved.
2, Value=1 , send Hail CC
3, Value=2 , send Barrier operator report CC

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 2
Options Send hail CC (1)      
  Send barrier operator report CC (2)      

241: Pair the Sensor

Pair the Sensor with Garage Door Controller

Overview

Pair the Sensor with Garage Door Controller.

Send Configuration Set:
Value=0x55555501, which will trigger to start the pairing of Sensor (installed on the top of the garage door), at this time, the Network LED on the Garage Door Controller will blink slowly and then short press Tamper Switch back of the Sensor.
If pairing is successful, the Network LED will stop blinking and the Garage Door Controller will send the configuration report with value=0x01FF to primary controller/gateway. Otherwise, repeat the operation.

Note:

  1. If you do not press the Tamper Switch when starting the pairing mode, the pairing status will keep for 8 second and then exit the pairing status automatically.
  2. The Sensor has been paired with the Garage Door Controller after factory.
Property Value      
Configuration ID config_241_4      
Data Type INTEGER   Default Value 0
Options Stop sensor pairing (0)      
  Start sensor pairing (1431655681)      

252: Lock Configuration

Enable/disable configuration

Overview

Enable/disable configuration
1, Value=0 : Enable.
2, Value=1 : Disable.

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Configuration enabled (0)      
  Configuration disabled (locked) (1)      

34: Sensor Calibration

Perform Sensor Calibration

Overview

Sensor Calibration.

Calibration Steps:

  1. Let the garage door move to full close position.
  2. Send this parameter (0x22) with “value=1” to Garage Door Controller.
  3. Let the garage door move to full open position.
  4. Let the garage door move to full close position after the step 3 is completed.

After the step 4 is completed, all calibration steps are complete.

Note: This process should be implemented when the Garage Door Controller just only has one Sensor is installed on the garage door.

Property Value      
Configuration ID config_34_1_wo      
Data Type INTEGER   Default Value 0
Options Calibration not active (0)      
  Begin calibration (1)      

42: Battery state

Configuration report for the battery state of Sensor

Overview

Configuration report for the battery state of Sensor:
1, Value=0x00: battery power is nominal.
2, Value=0x0F: battery power of Sensor is in low battery.
It will report the battery power state to associated nodes automatically when the battery power is in low battery.

Property Value
Configuration ID config_42_1_wo
Data Type INTEGER
Range to
Default Value 0

43: Play or Pause ringtone

Start playing or Stop playing the ringtone

Overview

Start playing or Stop playing the ringtone:
1, Value=255, stop playing ringtone.
2, Value=1 to 100, start playing the ringtone that you selected.

Property Value
Configuration ID config_43_1_wo
Data Type INTEGER
Range to
Default Value 1

44: Ringtone test volume

Set volume for test of ringtone

Overview

Test the volume of the current ringtone.

Value=1 to value=10, which map to the volume level 1 to level 10.

Property Value
Configuration ID config_44_1_wo
Data Type INTEGER
Range to
Default Value 1

1: Group 1

Position status changed

Overview

When the state of load (position status) is changed:

1, Set Configuration parameter 80 to 0 : Reserved (Default).
2, Set Configuration parameter 80 to 1 : Send Hail CC.
3, Set Configuration parameter 80 to 2: send Barrier operator report CC.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Forward the Basic Set

Overview

Forward the Basic Set, Switch Binary Set commands to associated nodes in Group 2 when the Garage Door Controller receives the Basic Set, Switch Binary Set commands from main controller.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.