Channels

The following table summarises the channels available for the ZW074 4 in One MultiSensor (G5).

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW074 4 in One MultiSensor (G5). Detailed information on each parameter can be found below.

Parameter Description
2: Wake up for 10 minutes when batteries are inserted  
3: On time How long should the device associated to multi sensor keep state On before sending it Off …
4: Motion sensor  
5: Command Class Which command would be sent when the motion sensor triggered.
40: Enable/disable the selective reporting  
41: Threshold for changes in temperature to trigger a report. 1. When the unit is Celsius, threshold=Value. 2. When the unit is Fahrenheit, threshold=Va…
42: Threshold for change in humidity to trigger a report. The accuracy is 0.1. The high byte is the part of integer, the low byte is the fractional …
43: luminance report threshold Threshold for changes in luminance to trigger a report. Note the sensor range is just 1-10…
44: Threshold change in battery level to induce an automatic report. The accuracy is 0.1. The high byte is the part of integer, the low byte is the fractional …
46: Enable/disable to send the alarm report of low temperature(‐15C)  
101: Which reports need to send automatically in timing intervals for group 1 The value is a combination number made up of the sum of the values for the individual sens…
102: Which reports need to send automatically in timing intervals for group 2 The value is a combination number made up of the sum of the values for the individual sens…
103: Which reports need to send automatically in timing intervals for group 3 The value is a combination number made up of the sum of the values for the individual sens…
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
252: Enable/disable Configuration Locked  
255: Reset to default factory setting.  
1: Lifeline  
2: Basic Set  
3: Dimmer Start/Stop  
4: Dimmer Set  
5: Temperature Report  

2: Wake up for 10 minutes when batteries are inserted

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 0

3: On time

How long should the device associated to multi sensor keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to next integer in minutes)

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 1 to 15300
Default Value 240

4: Motion sensor

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (1)      

5: Command Class

Which command would be sent when the motion sensor triggered.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Basic Set (1)      
  Sensor Binary Report (2)      

40: Enable/disable the selective reporting

Overview

Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in 41‐44 below.

This is used to reduce network traffic.

Property Value      
Configuration ID config_40_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

41: Threshold for changes in temperature to trigger a report.

  1. When the unit is Celsius, threshold=Value. 2. When the unit is Fahrenheit, threshold=Value*1.8. The accuracy is 0.1. 3. The high byte is the part of integer, the low byte is the fractional part.
Property Value
Configuration ID config_41_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

42: Threshold for change in humidity to trigger a report.

The accuracy is 0.1. The high byte is the part of integer, the low byte is the fractional part.

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

43: luminance report threshold

Threshold for changes in luminance to trigger a report. Note the sensor range is just 1-1000 lux !

Property Value
Configuration ID config_43_2
Data Type INTEGER
Range 0 to 1000
Default Value 0

44: Threshold change in battery level to induce an automatic report.

The accuracy is 0.1. The high byte is the part of integer, the low byte is the fractional part.

Property Value
Configuration ID config_44_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

46: Enable/disable to send the alarm report of low temperature(‐15C)

Property Value      
Configuration ID config_46_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enabled (The MultiSensor will report the Multi Level Temperature CC wi (1)      

101: Which reports need to send automatically in timing intervals for group 1

The value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have the values: Temperature=32, Humidity=64, Lightlevel=128, Battery=1. Therefore if you want all sensors and the batte

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

102: Which reports need to send automatically in timing intervals for group 2

The value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have the values: Temperature=32, Humidity=64, Lightlevel=128, Battery=1. Therefore if you want all sensors and the batte

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

103: Which reports need to send automatically in timing intervals for group 3

The value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have the values: Temperature=32, Humidity=64, Lightlevel=128, Battery=1. Therefore if you want all sensors and the batte

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 720

252: Enable/disable Configuration Locked

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enabled (1)      

255: Reset to default factory setting.

Property Value      
Configuration ID config_255_4_wo      
Data Type INTEGER   Default Value 1
Options Resets all configuration parameters to default setting. (1)      
  Reset the product to default factory setting and be excluded from the (1431655765)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic Set

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Dimmer Start/Stop

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Dimmer Set

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Temperature Report

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.