ZW075 Smart Energy Switch 3rd Edition

This describes the Z-Wave device ZW075, manufactured by AEON Labs with the thing type UID of aeon_zw075_00_000.

Smart Energy Switch 3rd Edition

Channels

The following table summarises the channels available for the ZW075 Smart Energy Switch 3rd Edition.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Reset Meter meter_reset meter_reset Energy Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW075 Smart Energy Switch 3rd Edition. Detailed information on each parameter can be found below.

Parameter Description
2: Blinking Behaviour The LSB defines the total time the device need to blink.
3: Current Overload Protection Load will be closed when the Current over runs
20: Output Load Status Configure the output load status after re‐power on.
80: Notification on Status Change Enable device to send notification to associated devices
81: Configure the state of red LED Enable the device to send notification to associated devices (Group 1)
90: Enables/disables parameter 91/92 Enable/Disable automated sending of report triggered by minimal change of value.
91: Minimum Change to send Report (Watt) The value represents the minimum change in Wattage for a Report to be sent.
92: Minimum Change to send Report (%) Minimum change in Wattage Percent for a report to be sent.
100: Set 101‐103 to default  Enable/Disable automated report triggered by min. change of value.
101: Report type to send to Group 1 The value is a combination number
102: Report type to send to Group 2 The value is a combination number
103: Report type to send to Group 3 The value is a combination number
111: Interval to send out reports to Group 1 Time Interval to send reports to Group 1
112: Interval to send out reports of group 2 Time interval to send reports of group 2
113: Interval to send out reports of group 3 Time interval when report of Reporting Group 3 is sent.
252: Enable/disable Configuration Lock  
1: Group 1  
2: Group 2  

2: Blinking Behaviour

The LSB defines the total time the device need to blink.

Overview

The LSB defines the total time the device need to blink. The value if set in seconds. 1 - 255 The MSB defines the on/off interval of the blinking. The unit is 0.1 s. This is a double byte value.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Current Overload Protection

Load will be closed when the Current over runs

Overview

 Load will be closed when the Current over runs (US: 15.5A, other country: 16.2A) for more than 2 minutes.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

20: Output Load Status

Configure the output load status after re‐power on.

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options Last Status (0)      
  Always On (1)      
  Always Off (2)      

80: Notification on Status Change

Enable device to send notification to associated devices

Overview

Enable device to send notification to associated devices (Group 1) when the state of Micro Smart Switch’s load changed. DEFAULT is Disable

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Hail CC Sent (1)      
  Basic CC Report Sent (2)      

81: Configure the state of red LED

Enable the device to send notification to associated devices (Group 1)

Overview

Enable the device to send notification to associated devices (Group 1) when the state of the Micro Smart Switch’s load changed

Property Value      
Configuration ID config_81_1      
Data Type INTEGER   Default Value 0
Options The LED will follow the status of its load (0)      
  Switch off after 5 seconds (1)      

90: Enables/disables parameter 91/92

Enable/Disable automated sending of report triggered by minimal change of value.

Overview

Users, who want a more constant monitoring of power consumption should set this value to 1. The reporting period is by default quite long ( approx. 35minutes)

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

91: Minimum Change to send Report (Watt)

The value represents the minimum change in Wattage for a Report to be sent.

Overview

 Range is 0 - 32000

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 32000
Default Value 25

92: Minimum Change to send Report (%)

Minimum change in Wattage Percent for a report to be sent.

Overview

The value represents the minimum change in Wattage Percent for a report to be sent. Range is 0 to 100%

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 5

100: Set 101‐103 to default

 Enable/Disable automated report triggered by min. change of value.

Overview

 Enable/Disable automated sending of report triggered by minimal change of value.

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 0
Options Set to Default (0)      
  Nothing (1)      

101: Report type to send to Group 1

The value is a combination number

Overview

The value is a combination number made up of the sum of the values for the individual parameters.

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Therefore if you want all parameters sending regular r

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

102: Report type to send to Group 2

The value is a combination number

Overview

The value is a combination number made up of the sum of the values for the individual parameters.

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

 Therefore if you want all parameters sending regular re

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 8

103: Report type to send to Group 3

The value is a combination number

Overview

The value is a combination number
made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular re

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Interval to send out reports to Group 1

Time Interval to send reports to Group 1

Overview

Defines the time interval when the defined report of Reporting Group 1 is sent out.

0 s - 65535 s - Interval

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 0 to 65535
Default Value 720

112: Interval to send out reports of group 2

Time interval to send reports of group 2

Overview

Defines the time interval when the defined report of Reporting Group 2 is sent out.

0 s - 65535 s - Interval

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 0 to 65535
Default Value 720

113: Interval to send out reports of group 3

Time interval when report of Reporting Group 3 is sent.

Overview

Defines the time interval when the defined report of Reporting Group 3 is sent out.

0 s - 65535 s - Interval

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 0 to 65535
Default Value 65535

252: Enable/disable Configuration Lock

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.