ZW078 Heavy Duty Switch

This describes the Z-Wave device ZW078, manufactured by AEON Labs with the thing type UID of aeon_zw078_00_000.

Heavy Duty Switch

Channels

The following table summarises the channels available for the ZW078 Heavy Duty Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW078 Heavy Duty Switch. Detailed information on each parameter can be found below.

Parameter Description
3: Current Overload Protection Load will be closed when current more that 39.5A and time more 5 seconds
20: Output Load Status Configure the output load status after re‐power on.
80: Notification on Status Change Send to group 1 on load change
90: Send report on value change Toggle automated report sending on change
91: Minimum Change to send Report (Watt) The value represents the minimum change in Wattage for a Report to be sent.
92: Minimum Change to send Report (%) Percent change in wattage to send report
101: reports to send automatically See overview
102: which reports to send to group 2 see overview
103: which reports to send to group 3 see overview
111: Interval to send out reports of group 1  
112: Interval to send out reports of group 2  
113: Interval to send out reports of group 3  
120: Turn External Button Mode Parameter to set External button type
1: Group 1  
2: Group 2  

3: Current Overload Protection

Load will be closed when current more that 39.5A and time more 5 seconds

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Activate (1)      

20: Output Load Status

Configure the output load status after re‐power on.

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options Last Status (0)      
  Always ON (1)      
  Always OFF (2)      

80: Notification on Status Change

Send to group 1 on load change

Overview

Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Switch’s load changed

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Deactivate (0)      
  Hail CC Sent (1)      
  Basic CC Report Sent (2)      

90: Send report on value change

Toggle automated report sending on change

Overview

Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value.

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Deavtivate (0)      
  Activate (1)      

91: Minimum Change to send Report (Watt)

The value represents the minimum change in Wattage for a Report to be sent.

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 65535
Default Value 25

92: Minimum Change to send Report (%)

Percent change in wattage to send report

Overview

The value represents the minimum change in Wattage Percent for a report to be sent.

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 255
Default Value 5

101: reports to send automatically

See overview

Overview

The value is a combination number made up of the sum of the values for the individual parameters.                                                       

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.                          

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 65535
Default Value 4

102: which reports to send to group 2

see overview

Overview

The value is a combination number made up of the sum of the values for the individual parameters.                                                       

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.                          

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 65535
Default Value 8

103: which reports to send to group 3

see overview

Overview

The value is a combination number made up of the sum of the values for the individual parameters.                                                       

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.                          

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Interval to send out reports of group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2678400
Default Value 3

112: Interval to send out reports of group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

113: Interval to send out reports of group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2678400
Default Value 600

120: Turn External Button Mode

Parameter to set External button type

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 255
Options Momentary Button Mode (0)      
  2 State Switch Mode (1)      
  3 Way Switch Mode (2)      

1: Group 1

Overview

The Node IDs in Group 1 will receive Hail Command/Basic report (configurable) when Heavy Duty Smart Switch Gen5’s level changed.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Overview

When the Heavy Duty Smart Switch Gen5 receives the commands Basic Set, Switch Binary Set, or Scene Activation Set it will forward the commands to all node IDs (in Group 2).

Property Value
Configuration ID group_2
Data Type TEXT
Range to