ZW080 Siren Gen5

This describes the Z-Wave device ZW080, manufactured by AEON Labs with the thing type UID of aeon_zw080_00_000.

Siren Gen5

Overview

Update command classes -:
METER:5 :: ADD
METER:6 :: ADD

Inclusion Information

  1. Install Siren, and plug it into the socket of AC Power.
  2. Let the primary controller into inclusion mode (If you don’t know how to do this, please refer to its manual).
  3. Press the Action Button.
  4. If the Learning is failed, please repeat the process from step 2.

Exclusion Information

  1. Install Siren, and plug it into the socket of AC Power.
  2. Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual). 3. Press the Action Button.
  3. If the remove is failed, please repeat the process from step 2.

Note: If Siren is removed from Z‐wave network, it will be reset to factory default.

Channels

The following table summarises the channels available for the ZW080 Siren Gen5.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sound and Volume config_decimal_param37 aeon_zw080_00_000_config_decimal_param37   Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW080 Siren Gen5. Detailed information on each parameter can be found below.

Parameter Description
37: Siren Sound  
37: Siren Volume  
80: Enable Notifications to Group 1 what type of notification to send to Group 1
200: Partner ID  
252: Enable/disable Lock Configuration  
1: Group 1  

37: Siren Sound

Property Value      
Configuration ID config_37_2_000000FF      
Data Type INTEGER      
Range 0 to 5   Default Value 1
Options Do not change the current Siren sound (0)      
  Siren sound 1 is selected (1)      
  Siren sound 2 is selected (2)      
  Siren sound 3 is selected (3)      
  Siren sound 4 is selected (4)      
  Siren sound 5 is selected (5)      

37: Siren Volume

Property Value      
Configuration ID config_37_2_0000FF00      
Data Type INTEGER      
Range 0 to 3   Default Value 3
Options Do not change the current volume (0)      
  Set the volume to 88 dB (1)      
  Set the volume to 100 dB (2)      
  Set the volume to 105 dB (3)      

80: Enable Notifications to Group 1

what type of notification to send to Group 1

Overview

Enable to send notifications to associated devices (Group1) when the state of Siren changed (0=nothing,1=hailCC,2=basic CC report).

Property Value
Configuration ID config_80_1
Data Type INTEGER
Range 0 to 255
Default Value 25

200: Partner ID

Property Value
Configuration ID config_200_1
Data Type INTEGER
Range 0 to 255
Default Value 0

252: Enable/disable Lock Configuration

Property Value      
Configuration ID config_252_1      
Data Type INTEGER      
Range 0 to 1   Default Value 0
Options Setting of configuration parameters is allowed (0)      
  All configuration parameters cannot be set (Locked) (1)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.