ZW089 Recessed Door Sensor Gen5

This describes the Z-Wave device ZW089, manufactured by AEON Labs with the thing type UID of aeon_zw089_00_000.

Recessed Door Sensor Gen5

Overview

Aeon Labs Recessed Door Sensor Gen5 is a door detector that can detect the state of the door’s open/close.

Inclusion Information

  1. Power on the Recessed Door Sensor Gen5.
  2. Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
  3. Press the Z‐Wave button.
  4. If the inclusion is success, Recessed Door Sensor Gen5’s LED will be kept turning on for 10 minutes. If the LED still blinks slowly, in which you need to repeat the process from step 2.  

Exclusion Information

  1. Power on the Recessed Door Sensor Gen5.
  2. Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual).
  3. Press the Z‐Wave button.
  4. If the exclusion is success, Recessed Door Sensor Gen5’s LED will blink slowly. If LED still be solid status for 3 seconds after you short press the Z‐Wave button, in which you need to repeat the process from step 2

Wakeup Information

Press and hold the Z‐wave Button for 6 seconds. It will sleep after you released the z‐wave button for 10 seconds, or sleep right away when received the Wake Up No More Information and then the led will turn off.   

Channels

The following table summarises the channels available for the ZW089 Recessed Door Sensor Gen5.

Channel Channel Id Channel Type UID Category Item Type
Door Status sensor_door sensor_door Door Contact
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW089 Recessed Door Sensor Gen5. Detailed information on each parameter can be found below.

Parameter Description
1: Send Sensor binary report on open/close events  
3: Send Basic Set on open/close event  
101: Low battery voltage check low battery check when voltage is less than warn voltage
111: Low battery voltage check time Minimum battery low check Interval time is 4 minutes
121: Configuration Value 4(LSB) SENSOR BINARY Configuration Value 4(LSB) SENSOR BINARY
121: Config value 3 - BASIC SET Set BASIC SET reporting
252: Permit other configurations Lock or Unlock other configuration set function
255: Reset to default Reset to the default configuration
1: State Updates  
2: Battery Warnings  

1: Send Sensor binary report on open/close events

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options On for opened, Off for closed (0)      
  Off for opened, On for closed (1)      

3: Send Basic Set on open/close event

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options On for opened, Off for closed (0)      
  Off for opened, On for closed (1)      

101: Low battery voltage check

low battery check when voltage is less than warn voltage

Overview

Enable/disable the function of low battery checking, when the current voltage is less than the warning voltage, it will send the Battery Low Warning Report. (00==Disable, 1==Enable) 

Property Value      
Configuration ID config_101_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

111: Low battery voltage check time

Minimum battery low check Interval time is 4 minutes

Overview

The Interval time of low battery checking (0~0xFFFFFFFF seconds). The minimum unit of interval time is 4 minutes. If the value is set to 1 minute, the interval time will be 4 minutes. The same is if the value is set to 7 minutes, the interval time will be 8 minutes. Note: 1, This parameter only will be activated after the function of low battery checking (parameter 101) is enabled. 2, Recessed Door Sensor also will check the current battery voltage when it was wake up as other ways (e. g. the Z ‐ Wave button trigger, magnet switch trigger, and the Wake Up Interval Set timeout trigger) after the function of low battery checking (parameter 101) is enabled.

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 240 to 2147483647
Default Value 86640

121: Configuration Value 4(LSB) SENSOR BINARY

Configuration Value 4(LSB) SENSOR BINARY

Overview

set to 16 for sensor binary (recommended)

set to 0 for factory default

Property Value      
Configuration ID config_121_4_000000FF      
Data Type INTEGER   Default Value 0
Options disable SENSOR BINARY (factory) (0)      
  enable SENSOR BINARY (16)      

121: Config value 3 - BASIC SET

Set BASIC SET reporting

Overview

Set to 1 for BASIC SET report (factory default)

Set to 0 to disable BASIC SET report

Property Value      
Configuration ID config_121_4_0000FF00      
Data Type INTEGER   Default Value 1
Options do not send BASIC SET (0)      
  send BASIC SET (factory default) (1)      

252: Permit other configurations

Lock or Unlock other configuration set function

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Unlock (0)      
  Lock (1)      

255: Reset to default

Reset to the default configuration

Overview

Reset all configuration parameters (except the parameter 254) to default settings

Property Value
Configuration ID config_255_1_wo
Data Type INTEGER
Range to
Default Value 0

1: State Updates

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Battery Warnings

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.