ZW097 Dry Contact Sensor

This describes the Z-Wave device ZW097, manufactured by AEON Labs with the thing type UID of aeon_zw097_00_000.

Dry Contact Sensor

Channels

The following table summarises the channels available for the ZW097 Dry Contact Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (smoke) alarm_smoke alarm_smoke Door Switch
Alarm (CO) alarm_co alarm_co Door Switch
Alarm (CO2) alarm_co2 alarm_co2 Door Switch
Alarm (heat) alarm_heat alarm_heat   Switch
Alarm (water) alarm_flood alarm_flood Door Switch
Alarm (access control) alarm_access alarm_access Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (power) alarm_power alarm_power Door Switch
Alarm (system) alarm_system alarm_system   Switch
Alarm (emergency) alarm_emergency alarm_emergency Door Switch
Alarm (clock) alarm_clock alarm_clock Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW097 Dry Contact Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Send Sensor binary report on open/close events  
2: Enable wake up 10 minutes when power on  
3: Send Basic Set on open/close event  
39: Send battery report when less than percentage  
111: Set the interval time of battery report Value is specified in number of seconds.
121: Send Sensor Binary report to associated devices  
121: Send Basic report to associated devices  
122: Notification type to send  
1: Group 1  

1: Send Sensor binary report on open/close events

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options On for opened, Off for closed (0)      
  Off for opened, On for closed (1)      

2: Enable wake up 10 minutes when power on

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

3: Send Basic Set on open/close event

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options On for opened, Off for closed (0)      
  Off for opened, On for closed (1)      

39: Send battery report when less than percentage

Property Value
Configuration ID config_39_1
Data Type INTEGER
Range 10 to 50
Default Value 10

111: Set the interval time of battery report

Value is specified in number of seconds.

Overview

Values greater than 10 will be rounded up to the nearest 4 minutes (10 through 240 = 4 minutes, 241 through 480 = 8 minutes, etc.)

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

121: Send Sensor Binary report to associated devices

Property Value
Configuration ID config_121_4_00000010
Data Type INTEGER
Range 0 to 1
Default Value 0

121: Send Basic report to associated devices

Property Value
Configuration ID config_121_4_00000100
Data Type INTEGER
Range 0 to 1
Default Value 1

122: Notification type to send

Property Value      
Configuration ID config_122_1_wo      
Data Type INTEGER   Default Value 6
Options Smoke alarm (1)      
  CO alarm (2)      
  CO2 alarm (3)      
  Heat alarm (4)      
  Water alarm (5)      
  Access control (6)      
  Home security (7)      
  Power management (8)      
  System (9)      
  Emergency alarm (10)      
  Timer ended (11)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.