ZW099 Smart Dimmer 6

This describes the Z-Wave device ZW099, manufactured by AEON Labs with the thing type UID of aeon_zw099_00_000.

Smart Dimmer 6

Overview

Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product’s housing.

Endpoint 1 is used to Set/Get the state of output load.

Endpoint 2 is used to Set/Get the brightness level of RGB LED when it is in Night light mode. 

Inclusion Information

  1. Insert the Smart Dimmer to power socket, The RGB LED will be colorful gradient status.
  2. Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
  3. Press the Action button.
  4. If the inclusion success, Smart Dimmer LED will be solid. Otherwise, the LED will remain colorful gradient status, in which you need to repeat the process from step 2. 

Exclusion Information

  1. Insert the Smart Dimmer to power socket, The Smart Dimmer LED will be solid.
  2. Let the primary controller into remove mode (If you don’t know how to do this, refer to its manual).
  3. Press the Action button.
  4. If the remove is successful, Smart Dimmer LED will be colorful gradient status. If Smart Dimmer LED still be solid, please repeat the process from step 2.

Channels

The following table summarises the channels available for the ZW099 Smart Dimmer 6.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Power Consumption (kWh) meter_kwh meter_kwh Energy Number
Energy Consumption (watts) meter_watts meter_watts Energy Number
Night mode color color_color color_color   Color

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW099 Smart Dimmer 6. Detailed information on each parameter can be found below.

Parameter Description
3: Current Overload Protection Toggle current overload protection
20: Initial Load State Configure the iniital output load state after re-power on
33: RGB LED Color Test Set the RGB LED color value for testing
80: Notification on Status Change Enable notifications for Group 1 device associations.
81: LED Indicator Mode Configure the LED mode.
83: LED Color for Night Light Configure the RGB value when it is in Night light mode
84: LED Brightness Brightness level of RGB LED (0%-100%)
91: Minimum Change to send Report (Watt) The minimum change in wattage value for a report to be sent
92: Minimum Change to send Report (%) The minimum change in wattage percentage for a report to be sent
101: Reports for Group 1 Define which reports to send in report group 1.
102: Reports for Group 2 Define which reports to send in report group 2.
103: Reports for Group 3 Define which reports to send in report group 3.
111: Report Group 1 Time Interval The time interval of sending Report group .
112: Report Group 2 Time Interval The time interval of sending Report group 2.
113: Report Group 3 Time Interval The time interval of sending Report group 3.
200: Partner ID Partner ID (0= Aeon Labs Standard Product, 1= others).
252: Configuration Lock Enable/disable Configuration Lock
254: Device Tag Device Tag
255: Reset to Factory Default Settings Reset to Factory Default Settings
90: Enable Report triggered by minimal change of value Enables/disables parameter 91 and 92 (reporting minimum wattage)
100: Reset Report Assignments for All Groups Reset the reports to send to each report group to default values.
110: Reset Report Time Intervals for All Groups Reset the reports time interval for each report group to default values.
1: Group 1 Lifeline
2: Group 2 Retransmit

3: Current Overload Protection

Toggle current overload protection

Overview

Output Load will be turned off automatically when the Current overrun 2.6A and the time more than 2 minutes (0=disabled, 1=enabled). 

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

20: Initial Load State

Configure the iniital output load state after re-power on

Overview

Configure the output load status after re-power on (0=last status, 1=always on, 2=always off) 

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options Last Status (0)      
  Always On (1)      
  Always Off (2)      

33: RGB LED Color Test

Set the RGB LED color value for testing

Overview

Set the RGB LED color value for testing (64-bit value).

  • Value1: Red value (0-255) (16-bits: 48-63)
  • Value2: Green value (0-255) (16-bits: 32-47)
  • Value3: Blue value (0-255) (16-bits: 16-31)
  • Value4: Reserved (0-255) (16-bits: 0-15)

Example Values:

  • Red = -16777216 (0xFF000000)
  • Green = 16711680 (0x00FF0000)
  • Blue = 65280 (0x0000FF00)

NOTE:
In OpenHAB and HABmin (or other Java software) To enter an unsigned integer value greater than 2147483647 you must convert the value to a signed 32-bit value.  

Property Value
Configuration ID config_33_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

80: Notification on Status Change

Enable notifications for Group 1 device associations.

Overview

Enable to send notifications to associated devices (Group 1) when the state of Smart Dimmer’s load changed (0=nothing, 1=hail CC, 2=basic CC report). 

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options None (0)      
  Hail (1)      
  Basic CC Report (2)      

81: LED Indicator Mode

Configure the LED mode.

Overview

Configure the state of LED when it is in 3 modes below:

  • 0= Energy mode, the LED will follow the status (on/off) of its load.
  • 1= Momentary indicate mode, when the state of Dimmer’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.
  • 2= Night light mode. 
Property Value      
Configuration ID config_81_1      
Data Type INTEGER   Default Value 0
Options Energy Mode (Load State) (0)      
  Momentary Mode (1)      
  Night Light Mode (2)      

83: LED Color for Night Light

Configure the RGB value when it is in Night light mode

Overview

Configure the RGB value when it is in Night light mode. (48-bit value)

  • Value1: Red color value (0-255) (16-bits: 32-47)
  • Value2: Green color value (0-255) (16-bits: 16-31)
  • Value3: Blue color value (0-255) (16-bits: 0-15)

Example Values:

  • Blue = 255 (0x0000FF)
  • Green = 65280 (0x00FF00)
  • Red = 16711680 (0xFF0000)
  • White = 1774619 (0xFFFFFF)
Property Value
Configuration ID config_83_3
Data Type INTEGER
Range 0 to 16777215
Default Value 1774619

84: LED Brightness

Brightness level of RGB LED (0%-100%)

Overview

Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. (48-bit value)

  • Value1: green brightness value. (0-100) (16-bits: 32-47)
  • Value2: yellow brightness value. (0-100) (16-bits: 16-31)
  • Value3: red brightness value. (0-100) (16-bits: 0-15)

Default value is 50% brightness on all colors: 3289650 (0x323232)

  • Green=50 (0x320000)
  • Yellow=50 (0x003200)
  • Red=50 (0x000032)

Maximum value is 100% brightness on all colors: 6579300 (0x646464)

  • Green=100 (0x640000)
  • Yellow=100 (0x006400)
  • Red=100 (0x000064)
Property Value
Configuration ID config_84_3
Data Type INTEGER
Range 0 to 6579300
Default Value 3289650

91: Minimum Change to send Report (Watt)

The minimum change in wattage value for a report to be sent

Overview

The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent (Valid values 0- 60000). 

Default value: 25 (watts)

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

92: Minimum Change to send Report (%)

The minimum change in wattage percentage for a report to be sent

Overview

The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent (Valid values 0-100).

Default value: 5 (%) 

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 5

101: Reports for Group 1

Define which reports to send in report group 1.

Overview

Which reports need to send in Report group 1 (See flags in user manual). 

See instruction manual for details on reporting configuration.

Property Value
Configuration ID config_101_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

102: Reports for Group 2

Define which reports to send in report group 2.

Overview

Which reports need to send in Report group 2 (See flags in user manual). 

See instruction manual for details on reporting configuration.

Property Value
Configuration ID config_102_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

103: Reports for Group 3

Define which reports to send in report group 3.

Overview

Which reports need to send in Report group 3 (See flags in user manual). 

See instruction manual for details on reporting configuration.

Property Value
Configuration ID config_103_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

111: Report Group 1 Time Interval

The time interval of sending Report group .

Overview

The time interval of sending Report group 1 (Valid values 0x01-0x7FFFFFFF). 

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 600

112: Report Group 2 Time Interval

The time interval of sending Report group 2.

Overview

The time interval of sending Report group 2 (Valid values 0x01-0x7FFFFFFF). 

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 600

113: Report Group 3 Time Interval

The time interval of sending Report group 3.

Overview

The time interval of sending Report group 3 (Valid values 0x01-0x7FFFFFFF). 

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 600

200: Partner ID

Partner ID (0= Aeon Labs Standard Product, 1= others).

Overview

Partner ID
(0= Aeon Labs Standard Product, 1= others). 

Property Value      
Configuration ID config_200_1      
Data Type INTEGER   Default Value 0
Options Aeon Labs Standard Product (0)      
  Others (1)      

252: Configuration Lock

Enable/disable Configuration Lock

Overview

Enable/disable Configuration Locked (0 =disable, 1 = enable). 

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

254: Device Tag

Device Tag

Property Value
Configuration ID config_254_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

255: Reset to Factory Default Settings

Reset to Factory Default Settings

Property Value      
Configuration ID config_255_1      
Data Type INTEGER   Default Value 0
Options Reset (0)      

90: Enable Report triggered by minimal change of value

Enables/disables parameter 91 and 92 (reporting minimum wattage)

Overview

Enables/disables parameter 91 (minimum change in wattage value) and 92 (minimum change in wattage percent).

Supported values: 1=enabled, 0=disabled

Property Value      
Configuration ID config_90_1_wo      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

100: Reset Report Assignments for All Groups

Reset the reports to send to each report group to default values.

Overview

Reset the reports to send to each report group to default values.
Set configuration parameters 101-103 to default. 
See instruction manual for details on reporting configuration.

Property Value      
Configuration ID config_100_1_wo      
Data Type INTEGER   Default Value 0
Options Do Nothing (0)      
  Reset to Defaults (1)      

110: Reset Report Time Intervals for All Groups

Reset the reports time interval for each report group to default values.

Overview

Reset the reports to time interval for each report group to default values.
Set configuration parameters 111-113 to default. 
See instruction manual for details on reporting configuration.

Property Value      
Configuration ID config_110_1_wo      
Data Type INTEGER   Default Value 0
Options Do Nothing (0)      
  Reset to Defaults (1)      

1: Group 1

Lifeline

Overview

When the state of Smart Dimmer(on/off/dim the load ) is changed:

  1. Set Configuration parameter 80 to 0:Reserved (Default).
  2. Set Configuration parameter 80 to 1:Send Hail CC.
  3. Set Configuration parameter 80 to 2: Send the Basic Report.  
Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Retransmit

Overview

Forward the Basic Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set to associated nodes in Group 2 when the Smart Dimmer receives the Basic Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set commands from main controller.  

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.