ZW100 MultiSensor 6

This describes the Z-Wave device ZW100, manufactured by AEON Labs with the thing type UID of aeon_zw100_00_000.

MultiSensor 6

Channels

The following table summarises the channels available for the ZW100 MultiSensor 6.

Channel Channel Id Channel Type UID Category Item Type
Sensor (motion) sensor_binary sensor_binary Door Switch
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (ultraviolet) sensor_ultraviolet sensor_ultraviolet Temperature Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Alarm (general) alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW100 MultiSensor 6. Detailed information on each parameter can be found below.

Parameter Description
2: Stay Awake in Battery Mode Stay awake for 10 minutes at power on
3: Motion Sensor reset timeout Motion Sensor reset timeout
4: Motion sensor sensitivity Sensitivity level of PIR sensor (1=minimum, 5=maximum)
5: Motion Sensor Triggered Command  
39: Low Battery Report Report Low Battery if below this value
40: Selective Reporting Select to report on thresholds
41: Temperature Threshold Temperature change threshold
42: Humidity Threshold Humidity percent change threshold
43: Luminance Threshold Luminance change threshold
44: Battery Threshold Battery level threshold
45: Ultraviolet Threshold Ultraviolet change threshold
46: Send Alarm Report if low temperature Send an alarm report if temperature is less than -15 °C
101: Group 1 Periodic Reports Periodic reports to send to Group 1
102: Group 2 Periodic Reports Periodic reports to send to Group 2
103: Group 3 Periodic Reports Periodic reports to send to Group 3
111: Group 1 Report Interval How often to update Group 1
112: Group 2 Report Interval Group 2 Report Interval
113: Group 3 Report Interval Group 3 Report Interval
201: Temperature Calibration Temperature calibration in 0.1 deg steps
202: Humidity Sensor Calibration Humidity Sensor Calibration
203: Luminance Sensor Calibration Luminance Sensor Calibration
204: Ultraviolet Sensor Calibration Ultraviolet Sensor Calibration
252: Lock Configuration Parameters  
100: Set parameters 101-103 to default. Reset 101-103 to defaults
110: Set parameters 111-113 to default. Set parameters 111-113 to default.
255: Reset to default factory settings  
1: Group 1  
2: Group 2  
3: Group 3  

2: Stay Awake in Battery Mode

Stay awake for 10 minutes at power on

Overview

Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.

  1. Value = 0, disable.
  2. Value =others, enable.
Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  enable (1)      

3: Motion Sensor reset timeout

Motion Sensor reset timeout

Overview
  1. The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC (0x00) to the associated nodes if no motion is triggered again in 4 minutes.
  2. Range: 10~3600.

Note:

  1. The time unit is second if the value range is in 10 to 255.
  2. If the value range is in 256 to 3600, the time unit will be minute and its value should follow the below rules:
    a), Interval time =Value/60, if the interval time can be divided by 60 and without remainder.
    b), Interval time= (Value/60) +1, if the interval time can be divided by 60 and has remainder.
  3. Other values will be ignored.
Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 10 to 3600
Default Value 240

4: Motion sensor sensitivity

Sensitivity level of PIR sensor (1=minimum, 5=maximum)

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 5
Options Disable (0)      
  Enable, sensitivity level 1 (minimum) (1)      
  Enable, sensitivity level 2 (2)      
  Enable, sensitivity level 3 (3)      
  Enable, sensitivity level 4 (4)      
  Enable, sensitivity level 5 (maximum) (5)      

5: Motion Sensor Triggered Command

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Send Basic Set CC (1)      
  Send Sensor Binary Report CC (2)      

39: Low Battery Report

Report Low Battery if below this value

Overview

Configure low battery value.
Value=10 to 50.(10% to 50%)

Property Value
Configuration ID config_39_1
Data Type INTEGER
Range 10 to 50
Default Value 20

40: Selective Reporting

Select to report on thresholds

Overview

Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in 41-44 below. This is used to reduce network traffic. (0 == disable, 1 == enable)

Property Value      
Configuration ID config_40_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

41: Temperature Threshold

Temperature change threshold

Overview

Threshold change in temperature to induce an automatic report.
Note:

  1. The unit is Fahrenheit for US version, Celsius for EU/AU version.
  2. The value contains one decimal point. E.g. if the value is set to 20, the threshold value =2.0°C (EU/AU version) or 2.0 °F (US version). When the current temperature gap is more then 2.0, which will induce a temperature report to be sent out.
Property Value
Configuration ID config_41_2
Data Type INTEGER
Range 0 to 100
Default Value 20

42: Humidity Threshold

Humidity percent change threshold

Overview

Threshold change in humidity to induce an automatic report.
Note:

  1. The unit is %.
  2. The default value is 10, which means that if the current humidity gap is
    more than 10%, it will send out a humidity report.
Property Value
Configuration ID config_42_1
Data Type INTEGER
Range 0 to 100
Default Value 10

43: Luminance Threshold

Luminance change threshold

Overview

Threshold change in luminance to induce an automatic report.

Property Value
Configuration ID config_43_2
Data Type INTEGER
Range 0 to 1000
Default Value 100

44: Battery Threshold

Battery level threshold

Overview

Threshold change in battery level to induce an automatic report.

Note:

  1. The unit is %.
  2. The default value is 10, which means that if the current battery level gap is
    more than 10%, it will send out a battery report.
Property Value
Configuration ID config_44_1
Data Type INTEGER
Range 0 to 100
Default Value 10

45: Ultraviolet Threshold

Ultraviolet change threshold

Overview

Threshold change in ultraviolet to induce an automatic report.

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 0 to 100
Default Value 2

46: Send Alarm Report if low temperature

Send an alarm report if temperature is less than -15 °C

Property Value      
Configuration ID config_46_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

101: Group 1 Periodic Reports

Periodic reports to send to Group 1

Overview

This value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have these values:

  • Battery=1
  • Ultraviolet=16
  • Temperature=32
  • Humidity=64
  • Light=128

1+16+32+64+128 = 241 and is the default value

Property Value
Configuration ID config_101_4_000000FF
Data Type INTEGER
Range 0 to 65535
Default Value 241

102: Group 2 Periodic Reports

Periodic reports to send to Group 2

Overview

This value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have these values:

  • Battery=1
  • Ultraviolet=16
  • Temperature=32
  • Humidity=64
  • Light=128
Property Value
Configuration ID config_102_4_000000FF
Data Type INTEGER
Range 0 to 65535
Default Value 0

103: Group 3 Periodic Reports

Periodic reports to send to Group 3

Overview

This value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have these values:

  • Battery=1
  • Ultraviolet=16
  • Temperature=32
  • Humidity=64
  • Light=128
Property Value
Configuration ID config_103_4_000000FF
Data Type INTEGER
Range 0 to 65535
Default Value 0

111: Group 1 Report Interval

How often to update Group 1

Overview

The interval time of sending reports in Report group 1 (Valid values 0x05-0x28DE80).

  1. The unit of interval time is second if USB power.
  2. If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes. You can also change the minimum interval time to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set CC.
Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 5 to 2678400
Default Value 3600

112: Group 2 Report Interval

Group 2 Report Interval

Overview

The interval time of sending reports in Report group 2 (Valid values 0x05-
0x28DE80).
Note:

  1. The unit of interval time is second if USB power.
  2. If battery power, the minimum interval time is 60 minutes by default, for
    example, if the value is set to be more than 5 and less than 3600, the interval
    time is 60 minutes, if the value is set to be more than 3600 and less than 7200,
    the interval time is 120 minutes. You can also change the minimum interval time
    to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set
    CC.
Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 5 to 2678400
Default Value 3600

113: Group 3 Report Interval

Group 3 Report Interval

Overview

The interval time of sending reports in Report group 3

  1. The unit of interval time is second if USB power.
  2. If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes. You can also change the minimum interval time to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set CC.
Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 5 to 2678400
Default Value 3600

201: Temperature Calibration

Temperature calibration in 0.1 deg steps

Overview

Temperature calibration (the available value range is [-100,100] or [-10°C ,10 °C ] ).
Note:

  1. The value contains one decimal point. E.g. if the value is set to 20, the calibration value is 2.0°C (EU/AU version) or 2.0 °F (US version)
  2. The calibration value = standard value - measure value. °C and the standard value = 23.2 °C , so the calibration value= 23.2 °C - 25.3 °C = -2.1 °C (0xEB).

If the measure value =30.1 °C and the standard value = 33.2 °C , so the calibration value= 33.2 °C - 30.1 °C =3.1 °C (0x1F).

Property Value
Configuration ID config_201_1
Data Type INTEGER
Range -100 to 100
Default Value 0

202: Humidity Sensor Calibration

Humidity Sensor Calibration

Overview

Humidity sensor calibration (the available value range is [-50, 50]).
The calibration value = standard value - measure value.
E.g. If measure value =80RH and the standard value = 75RH, so the calibration
value= 75RH – 80RH= -5RH (0xFB).
If the measure value =85RH and the standard value = 90RH, so the calibration
value= 90RH – 85RH=5RH (0x05).

Property Value
Configuration ID config_202_1
Data Type INTEGER
Range -50 to 50
Default Value 0

203: Luminance Sensor Calibration

Luminance Sensor Calibration

Overview

Luminance sensor calibration (the available value range is [-1000, 1000]).
The calibration value = standard value - measure value.
E.g. If measure value =800Lux and the standard value = 750Lux, so the
calibration value= 750 – 800= -50 (0xFFCE).
If the measure value =850Lux and the standard value = 900Lux, so the calibration
value= 900 – 850=50 (0x0032).

Property Value
Configuration ID config_203_2
Data Type INTEGER
Range -1000 to 1000
Default Value 0

204: Ultraviolet Sensor Calibration

Ultraviolet Sensor Calibration

Overview

Ultraviolet sensor calibration (the available value range is [-10, 10]).
The calibration value = standard value - measure value.
E.g. If measure value =9 and the standard value = 8, so the calibration value= 8 –
9= -1 (0xFE).
If the measure value =7 and the standard value = 9, so the calibration value= 9 –
7=2 (0x02).

Property Value
Configuration ID config_204_1
Data Type INTEGER
Range -10 to 10
Default Value 0

252: Lock Configuration Parameters

Overview

Enable/disable Configuration Locked (0 =disable, 1 = enable).

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

100: Set parameters 101-103 to default.

Reset 101-103 to defaults

Overview

Set 101-103 to default.

Property Value
Configuration ID config_100_1_wo
Data Type INTEGER
Range to
Default Value 0

110: Set parameters 111-113 to default.

Set parameters 111-113 to default.

Overview

Set parameters 111-113 to default.   

Property Value
Configuration ID config_110_1_wo
Data Type INTEGER
Range to
Default Value 0

255: Reset to default factory settings

Property Value      
Configuration ID config_255_4_wo      
Data Type INTEGER   Default Value 0
Options Resets all configuration parameters to defaults (1)      
  Reset to default factory settings and be excluded (1431655765)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.