ZW100 MultiSensor 6
This describes the Z-Wave device ZW100, manufactured by AEON Labs with the thing type UID of aeon_zw100_01_008
.
MultiSensor 6
Overview
RESET - Press and hold for 20 seconds
- Reset MultiSensor to factory default:
- Press and hold the Action Button for 20 seconds.
- If holding time more than one second, the LED will blink faster and faster. If holding time more than
20 seconds, the LED will be on for 2 seconds, which indicates reset is success, otherwise please
repeat step 2.
- Note:
1, This procedure should only be used when the primary controller is inoperable.
2, Reset MultiSensor to factory default settings, it will:
a ), let the MultiSensor to be excluded in Z-Wave network;
b), delete the Association settings;
c), restore the Configuration settings to the default.
Inclusion Information
Click one time
- Send non-security Node Info frame
- Add MultiSensor into Z-Wave network(non-security inclusion):
- Power on MultiSensor. The MultiSensor’s LED will blink slowly when you short press the Action
Button. - Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Action Button.
- If the inclusion is success, MultiSensor’s LED will be kept turning on for 8 seconds when you short
press the Action Button. If the LED is still in slow blink, in which you need to repeat the process from
step 2.
- Power on MultiSensor. The MultiSensor’s LED will blink slowly when you short press the Action
Short press 2 times within 1 second
-
- Send Security Node Info frame.
- Add MultiSensor into z-wave network(Security inclusion):
- Power on MultiSensor. The MultiSensor’s LED will blink slowly when you short press the Action
Button. - Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Action Button.
- If the inclusion is success, MultiSensor’s LED will be kept turning on for 8 seconds when you short
press the Action Button. If the LED is still in slow blink, in which you need to repeat the process from
step 2.
Exclusion Information
Remove MultiSensor from Z-wave network:
- Power on MultiSensor. The MultiSensor’s LED will be kept turning on for 8 seconds when you short
press the Action Button. - Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Action Button.
- If the exclusion is success, MultiSensor’s LED will blink slowly when you short press the Action
Button. If MultiSensor’s LED still keeps on status, in which you need to repeat the process from step 2.
Wakeup Information
Press and hold for 3 seconds
Enable/disable wake up for 10 minutes.
(When it is enabled, the orange Led will fast blink)
Channels
The following table summarises the channels available for the ZW100 MultiSensor 6.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Binary Sensor | sensor_binary | sensor_binary | Door | Switch |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number |
Sensor (luminance) | sensor_luminance | sensor_luminance | Temperature | Number |
Sensor (ultraviolet) | sensor_ultraviolet | sensor_ultraviolet | Temperature | Number |
Tamper Alarm | alarm_tamper | alarm_tamper | Switch | |
Motion Alarm | alarm_motion | alarm_motion | Door | Switch |
battery-level | system.battery-level |
Sensor (temperature)
Scale
Select the scale for temperature readings
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_scale | |||
Data Type | TEXT | Default Value | 0 | |
Options | Celsius (0) | |||
Fahrenheit (1) |
Device Configuration
The following table provides a summary of the configuration parameters available in the ZW100 MultiSensor 6. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
2: Stay Awake in Battery Mode | Stay awake for 10 minutes at power on |
3: Motion Sensor reset timeout | Motion Sensor reset timeout |
4: Motion sensor sensitivity | Sensitivity level of PIR sensor (1=minimum, 5=maximum) |
5: Motion Sensor Triggered Command | |
8: Timeout after wake up | Set the timeout of awake after the Wake Up CC is sent out… |
9: Report the current power mode | Report the current power mode and the product state of battery power mode |
39: Low Battery Report | Report Low Battery if below this value |
40: Selective Reporting | Select to report on thresholds |
41: Temperature Threshold Unit | Sets the unit of the threshold |
41: Temperature Threshold | Threshold change in temperature to induce an automatic report. |
42: Humidity Threshold | Humidity percent change threshold |
43: Luminance Threshold | Luminance change threshold |
44: Battery Threshold | Battery level threshold |
45: Ultraviolet Threshold | Ultraviolet change threshold |
46: Send Alarm Report if low temperature | Send an alarm report if temperature is less than -15 °C |
81: LED function | Disable/Enable LED function |
101: Group 1 Periodic Reports | Periodic reports to send to Group 1 |
102: Group 2 Periodic Reports | Periodic reports to send to Group 2 |
103: Group 3 Periodic Reports | Periodic reports to send to Group 3 |
111: Group 1 Report Interval | How often to update Group 1 |
112: Group 2 Report Interval | Group 2 Report Interval |
113: Group 3 Report Interval | Group 3 Report Interval |
201: Temperature Calibration | Temperature calibration in 0.1 deg steps |
201: Temperature Calibration Unit | |
201: Temperature Calibration Value | Calibration value containing one decimal point |
202: Humidity Sensor Calibration | Humidity Sensor Calibration |
203: Luminance Sensor Calibration | Luminance Sensor Calibration |
204: Ultraviolet Sensor Calibration | Ultraviolet Sensor Calibration |
252: Lock Configuration Parameters | Enable or Disable changing of configuration parameters |
41: Temperature Threshold | Temperature change threshold |
100: Set parameters 101-103 to default. | Reset 101-103 to defaults |
110: Set parameters 111-113 to default. | Set parameters 111-113 to default. |
255: Reset to default factory settings | |
1: Group 1 | |
2: Group 2 | |
3: Group 3 |
2: Stay Awake in Battery Mode
Stay awake for 10 minutes at power on
Overview
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
- Value = 0, disable.
- Value =others, enable.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_2_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
enable (1) |
3: Motion Sensor reset timeout
Motion Sensor reset timeout
Overview
- The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC (0x00) to the associated nodes if no motion is triggered again in 4 minutes.
- Range: 10~3600.
Note:
- The time unit is second if the value range is in 10 to 255.
- If the value range is in 256 to 3600, the time unit will be minute and its value should follow the below rules:
a), Interval time =Value/60, if the interval time can be divided by 60 and without remainder.
b), Interval time= (Value/60) +1, if the interval time can be divided by 60 and has remainder. - Other values will be ignored.
Property | Value |
---|---|
Configuration ID | config_3_2 |
Data Type | INTEGER |
Range | 10 to 3600 |
Default Value | 240 |
4: Motion sensor sensitivity
Sensitivity level of PIR sensor (1=minimum, 5=maximum)
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_4_1 | |||
Data Type | INTEGER | Default Value | 5 | |
Options | Disable (0) | |||
Enable, sensitivity level 1 (minimum) (1) | ||||
Enable, sensitivity level 2 (2) | ||||
Enable, sensitivity level 3 (3) | ||||
Enable, sensitivity level 4 (4) | ||||
Enable, sensitivity level 5 (maximum) (5) |
5: Motion Sensor Triggered Command
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_5_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Send Basic Set CC (1) | |||
Send Sensor Binary Report CC (2) |
8: Timeout after wake up
Set the timeout of awake after the Wake Up CC is sent out…
Property | Value |
---|---|
Configuration ID | config_8_1 |
Data Type | INTEGER |
Range | 8 to 255 |
Default Value | 30 |
9: Report the current power mode
Report the current power mode and the product state of battery power mode
Overview
Value1 (MSB): 0x00=USB power mode, 0x01=Battery power mode
Value2 (LSB): 0x00=keep sleep state for Battery power mode, 0x01=keep awake for 10 minutes for battery power mode
NOTE: this parameter cannot be used as Get/Set usage
Property | Value |
---|---|
Configuration ID | config_9_2 |
Data Type | INTEGER |
Range | 0 to 1 |
Default Value | 0 |
39: Low Battery Report
Report Low Battery if below this value
Overview
Configure low battery value.
Value=10 to 50.(10% to 50%)
Property | Value |
---|---|
Configuration ID | config_39_1 |
Data Type | INTEGER |
Range | 10 to 50 |
Default Value | 20 |
40: Selective Reporting
Select to report on thresholds
Overview
Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in 41-44 below. This is used to reduce network traffic. (0 == disable, 1 == enable)
Note: If USB Power, the Sensor will check threshold every 10 seconds. If battery power, the Sensor will check the threshold when it is waken up.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_40_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
Enable (1) |
41: Temperature Threshold Unit
Sets the unit of the threshold
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_41_2_000000FF | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Celsius (1) | |||
Fahrenheit (2) |
41: Temperature Threshold
Threshold change in temperature to induce an automatic report.
Property | Value |
---|---|
Configuration ID | config_41_2_0000FF00 |
Data Type | INTEGER |
Range | 0 to 100 |
Default Value | 0 |
42: Humidity Threshold
Humidity percent change threshold
Overview
Threshold change in humidity to induce an automatic report.
Note:
- The unit is %.
- The default value is 10, which means that if the current humidity gap is
more than 10%, it will send out a humidity report.
Property | Value |
---|---|
Configuration ID | config_42_1 |
Data Type | INTEGER |
Range | 0 to 100 |
Default Value | 10 |
43: Luminance Threshold
Luminance change threshold
Overview
Threshold change in luminance to induce an automatic report.
Property | Value |
---|---|
Configuration ID | config_43_2 |
Data Type | INTEGER |
Range | 0 to 1000 |
Default Value | 100 |
44: Battery Threshold
Battery level threshold
Overview
Threshold change in battery level to induce an automatic report.
Note:
- The unit is %.
- The default value is 10, which means that if the current battery level gap is
more than 10%, it will send out a battery report.
Property | Value |
---|---|
Configuration ID | config_44_1 |
Data Type | INTEGER |
Range | 0 to 100 |
Default Value | 10 |
45: Ultraviolet Threshold
Ultraviolet change threshold
Overview
Threshold change in ultraviolet to induce an automatic report.
Property | Value |
---|---|
Configuration ID | config_45_1 |
Data Type | INTEGER |
Range | 0 to 100 |
Default Value | 2 |
46: Send Alarm Report if low temperature
Send an alarm report if temperature is less than -15 °C
Overview
Enable/Disable to send the alarm report of low temperature (<-15°C)
Value=0, disable
Value=1, enable (The MultiSensor will send a report of Multi Level Temperature CC to controller if the current temperature is less then -15°C).
Note: The battery activity will reduced at low temperatures (-15 degrees Celsius and below), wich will lead to the product may not work normally. It is recommended to use USB power at low temperatures.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_46_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
Enable (1) |
81: LED function
Disable/Enable LED function
Overview
Disable/Enable LED function (0: enabled 1: disabled)
Property | Value |
---|---|
Configuration ID | config_81_1 |
Data Type | INTEGER |
Range | 0 to 1 |
Default Value | 0 |
101: Group 1 Periodic Reports
Periodic reports to send to Group 1
Overview
This value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have these values:
- Battery=1
- Ultraviolet=16
- Temperature=32
- Humidity=64
- Light=128
1+16+32+64+128 = 241 and is the default value
Property | Value |
---|---|
Configuration ID | config_101_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 241 |
102: Group 2 Periodic Reports
Periodic reports to send to Group 2
Overview
This value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have these values:
- Battery=1
- Ultraviolet=16
- Temperature=32
- Humidity=64
- Light=128
Property | Value |
---|---|
Configuration ID | config_102_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 0 |
103: Group 3 Periodic Reports
Periodic reports to send to Group 3
Overview
This value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have these values:
- Battery=1
- Ultraviolet=16
- Temperature=32
- Humidity=64
- Light=128
Property | Value |
---|---|
Configuration ID | config_103_4 |
Data Type | INTEGER |
Range | 0 to 65535 |
Default Value | 0 |
111: Group 1 Report Interval
How often to update Group 1
Overview
The interval time of sending reports in Report group 1 (Valid values 0x05-0x28DE80).
- The unit of interval time is second if USB power.
- If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes. You can also change the minimum interval time to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set CC.
Property | Value |
---|---|
Configuration ID | config_111_4 |
Data Type | INTEGER |
Range | 5 to 2678400 |
Default Value | 3600 |
112: Group 2 Report Interval
Group 2 Report Interval
Overview
The interval time of sending reports in Report group 2 (Valid values 0x05-
0x28DE80).
Note:
- The unit of interval time is second if USB power.
- If battery power, the minimum interval time is 60 minutes by default, for
example, if the value is set to be more than 5 and less than 3600, the interval
time is 60 minutes, if the value is set to be more than 3600 and less than 7200,
the interval time is 120 minutes. You can also change the minimum interval time
to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set
CC.
Property | Value |
---|---|
Configuration ID | config_112_4 |
Data Type | INTEGER |
Range | 5 to 2678400 |
Default Value | 3600 |
113: Group 3 Report Interval
Group 3 Report Interval
Overview
The interval time of sending reports in Report group 3
- The unit of interval time is second if USB power.
- If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes. You can also change the minimum interval time to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set CC.
Property | Value |
---|---|
Configuration ID | config_113_4 |
Data Type | INTEGER |
Range | 5 to 2678400 |
Default Value | 3600 |
201: Temperature Calibration
Temperature calibration in 0.1 deg steps
Overview
Temperature calibration (the available value range is [-128,127] or [-12.8°C ,12.7 °C ] ).
Note:
- High byte is the calibration value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).
- The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1401), the calibration value is 2.0°C (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0 °F (US version)
- The calibration value = standard value - measure value. °C and the standard value = 23.2 °C , so the calibration value= 23.2 °C - 25.3 °C = -2.1 °C (0xEB). If the measure value =30.1 °C and the standard value = 33.2 °C , so the calibration value= 33.2 °C - 30.1 °C =3.1 °C (0x1F).
Property | Value |
---|---|
Configuration ID | config_201_2 |
Data Type | INTEGER |
Range | -128 to 127 |
Default Value | 0 |
201: Temperature Calibration Unit
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_201_2_000000FF | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Celsius (1) | |||
Fahrenheit (2) |
201: Temperature Calibration Value
Calibration value containing one decimal point
Property | Value |
---|---|
Configuration ID | config_201_2_0000FF00 |
Data Type | INTEGER |
Range | -127 to 127 |
Default Value | 0 |
202: Humidity Sensor Calibration
Humidity Sensor Calibration
Overview
Humidity sensor calibration (the available value range is [-50, 50]).
The calibration value = standard value - measure value.
E.g. If measure value =80RH and the standard value = 75RH, so the calibration
value= 75RH – 80RH= -5RH (0xFB).
If the measure value =85RH and the standard value = 90RH, so the calibration
value= 90RH – 85RH=5RH (0x05).
Property | Value |
---|---|
Configuration ID | config_202_1 |
Data Type | INTEGER |
Range | -50 to 50 |
Default Value | 0 |
203: Luminance Sensor Calibration
Luminance Sensor Calibration
Overview
Luminance sensor calibration (the available value range is [-1000, 1000]).
The calibration value = standard value - measure value.
E.g. If measure value =800Lux and the standard value = 750Lux, so the
calibration value= 750 – 800= -50 (0xFFCE).
If the measure value =850Lux and the standard value = 900Lux, so the calibration
value= 900 – 850=50 (0x0032).
Property | Value |
---|---|
Configuration ID | config_203_2 |
Data Type | INTEGER |
Range | -1000 to 1000 |
Default Value | 0 |
204: Ultraviolet Sensor Calibration
Ultraviolet Sensor Calibration
Overview
Ultraviolet sensor calibration (the available value range is [-10, 10]).
The calibration value = standard value - measure value.
E.g. If measure value =9 and the standard value = 8, so the calibration value= 8 –
9= -1 (0xFE).
If the measure value =7 and the standard value = 9, so the calibration value= 9 –
7=2 (0x02).
Property | Value |
---|---|
Configuration ID | config_204_1 |
Data Type | INTEGER |
Range | -10 to 10 |
Default Value | 0 |
252: Lock Configuration Parameters
Enable or Disable changing of configuration parameters
Overview
Enable/disable Configuration Locked (0 =disable, 1 = enable).
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_252_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
Enable (1) |
41: Temperature Threshold
Temperature change threshold
Overview
Threshold change in temperature to induce an automatic report.
Note:
- The unit is Fahrenheit for US version, Celsius for EU/AU version.
- High byte is the threshold value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).
- The threshold value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1401), the threshold value =2.0°C (EU/AU version) or if the value is set to 20 (0x1402), the threshold value=2.0 °F (US version). When the current temperature gap is more then 2.0, which will induce a temperature report to be sent out.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_41_2_wo | |||
Data Type | INTEGER | Default Value | 20 | |
Options | Temperature Threshold Unit (0) |
100: Set parameters 101-103 to default.
Reset 101-103 to defaults
Overview
Set 101-103 to default.
Property | Value |
---|---|
Configuration ID | config_100_1_wo |
Data Type | INTEGER |
Range | to |
Default Value | 0 |
110: Set parameters 111-113 to default.
Set parameters 111-113 to default.
Overview
Set parameters 111-113 to default.
Property | Value |
---|---|
Configuration ID | config_110_1_wo |
Data Type | INTEGER |
Range | to |
Default Value | 0 |
255: Reset to default factory settings
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_255_4_wo | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Resets all configuration parameters to defaults (1) | |||
Reset to default factory settings and be excluded (1431655765) |
1: Group 1
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
2: Group 2
Property | Value |
---|---|
Configuration ID | group_2 |
Data Type | TEXT |
Range | to |
3: Group 3
Property | Value |
---|---|
Configuration ID | group_3 |
Data Type | TEXT |
Range | to |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.