ZW111 Nano Dimmer

This describes the Z-Wave device ZW111, manufactured by AEON Labs with the thing type UID of aeon_zw111_00_000.

Nano Dimmer

Overview

Aeotec Nano Dimmer is a Z-Wave Smart Dimmer specifically used to enable Z-Wave command and control (on/off/dim) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status.
It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Nano Dimmer.
The Nano Dimmer is also a security Z-Wave plus device and supports Over The Air (OTA) feature for the products firmware upgrade.

Channels

The following table summarises the channels available for the ZW111 Nano Dimmer.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number   Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm (power) alarm_power alarm_power Door Switch
Alarm (heat) alarm_heat alarm_heat   Switch
Clock Time Offset time_offset time_offset Temperature Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW111 Nano Dimmer. Detailed information on each parameter can be found below.

Parameter Description
3: Current Overload Protection Current Overload Protection
4: Overheat protection Overheat protection
20: Configure the output status after re-power on it Configure the output status after re-power on it
80: Group 1 notificaiton Set notification sent to associated nodes (group 1)
81: Group 3 notificaiton Set notification sent to associated nodes (group 3)
82: Group 4 notificaiton Set notification sent to associated nodes (group 4)
85: Set appointment 1 Set appointment 1
86: Set appointment 2 Set appointment 2
90: (En/dis)able 91 and 92 Enables/disables parameter 91 and 92
91: Set the threshold value of wattage Threshold change in wattage (in terms of wattage) to induce an automatic report
92: Set the threshold value of wattage Threshold change in wattage (in terms of percentage)
101: Set group 1 reports To set which reports need to be sent in Report group 1
102: Set group 2 reports To set which reports need to be sent in Report group 2
103: To set which reports need to be sent in Report group 3 To set which reports need to be sent in Report group 3
111: Automatic report interval group 1 Set the interval of automatic report for Report group 1
112: Automatic report interval group 2 Set the interval of automatic report for Report group 2
113: Automatic report interval group 3 Set the interval of automatic report for Report group 3
121: Configure the external switch mode for S2 Configure the external switch mode for S2
122: Get the state of touch panel port Get the state of touch panel port
123: Set the control destination for external switch S1 Set the control destination for external switch S1
124: Set the control destination for external switch S2 Set the control destination for external switch S2
125: Set the default dimming rate The value range is 1 to 255 seconds
128: Get the current working mode Get the current working mode
129: Set the dimming principle Set the dimming principle
130: To get what type of load the Dimmer is connected to To get what type of load the Dimmer is connected to.
131: Set the min brightness level that the load can reach to Set the min brightness level that the load can reach to
132: Set the max brightness level that the load can reach to Set the max brightness level that the load can reach to
249: Set the recognition way of load Set the recognition way of load
252: Lock/unlock configuration parameters Lock/unlock configuration parameters
255: Reset the Nano Dimmer Reset the Nano Dimmer
100: Reset 101-103 to default Reset parameters 101-103 to default values
110: Reset 111-113 to default Reset parameters 111-113 to default values
120: Configure the external switch mode for S1 Configure the external switch mode for S1
1: Z-Wave Plus Lifeline Z-Wave Plus Lifeline
2: Forward  
3: Send Basic Set (Group 3) Sw 1  
4: Send Basic Set (Group 3) Sw 2  

3: Current Overload Protection

Current Overload Protection

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  (Default) Enable (1)      

4: Overheat protection

Overheat protection

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options (Default) Disable (0)      
  Enable (1)      

20: Configure the output status after re-power on it

Configure the output status after re-power on it

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options (Default) Last status (0)      
  Always on (1)      
  Always off (2)      

80: Group 1 notificaiton

Set notification sent to associated nodes (group 1)

Overview

To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmer’s load is changed.

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options (Default) Send Nothing (0)      
  Send Hail CC (1)      
  Send Basic CC report (2)      
  Send Multilevel Switch report (3)      
  Send Hail CC when using the manual switch (4)      

81: Group 3 notificaiton

Set notification sent to associated nodes (group 3)

Overview

set notification sent to associated nodes (group 4)

To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads.

Property Value      
Configuration ID config_81_1      
Data Type INTEGER   Default Value 0
Options Send Nothing (0)      
  (Default) Send Basic Set CC (1)      

82: Group 4 notificaiton

Set notification sent to associated nodes (group 4)

Overview

To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads.

Property Value      
Configuration ID config_82_1      
Data Type INTEGER   Default Value 1
Options Send Nothing (0)      
  (Default) Send Basic Set CC (1)      

85: Set appointment 1

Set appointment 1

Overview

0 to 99     The brightness level
256 to 316     The minute value of ON time
65536 to 65560     The hour value of ON time
16777215 to 16777222     The day value (Mon to Sun)

Property Value
Configuration ID config_85_4
Data Type INTEGER
Range 0 to 16843197
Default Value 0

86: Set appointment 2

Set appointment 2

Overview

0 to 99     The brightness level
256 to 316     The minute value of ON time
65536 to 65560     The hour value of ON time
16777215 to 16777222     The day value (Mon to Sun)

Property Value
Configuration ID config_86_4
Data Type INTEGER
Range 0 to 16843197
Default Value 0

90: (En/dis)able 91 and 92

Enables/disables parameter 91 and 92

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options (Default) Disable (0)      
  Enable (1)      

91: Set the threshold value of wattage

Threshold change in wattage (in terms of wattage) to induce an automatic report

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

92: Set the threshold value of wattage

Threshold change in wattage (in terms of percentage)

Overview

Threshold change in wattage (in terms of percentage) to induce an automatic report

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 5

101: Set group 1 reports

To set which reports need to be sent in Report group 1

Overview

1     Send Meter Report of voltage (V)
2     Send Meter Report of current (A)
4     Send Meter Report of wattage (W)
8     Send Meter Report of energy (kWh)

Property Value
Configuration ID config_101_1
Data Type INTEGER
Range 0 to 255
Default Value 0

102: Set group 2 reports

To set which reports need to be sent in Report group 2

Overview

1     Send Meter Report of voltage (V)
2     Send Meter Report of current (A)
4     Send Meter Report of wattage (W)
8     Send Meter Report of energy (kWh)

Property Value
Configuration ID config_102_1
Data Type INTEGER
Range 0 to 255
Default Value 0

103: To set which reports need to be sent in Report group 3

To set which reports need to be sent in Report group 3

Overview

1     Send Meter Report of voltage (V)
2     Send Meter Report of current (A)
4     Send Meter Report of wattage (W)
8     Send Meter Report of energy (kWh)

Property Value
Configuration ID config_103_1
Data Type INTEGER
Range 0 to 15
Default Value 0

111: Automatic report interval group 1

Set the interval of automatic report for Report group 1

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 2147483647

112: Automatic report interval group 2

Set the interval of automatic report for Report group 2

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 2147483647

113: Automatic report interval group 3

Set the interval of automatic report for Report group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 2147483647

121: Configure the external switch mode for S2

Configure the external switch mode for S2

Property Value      
Configuration ID config_121_1      
Data Type INTEGER   Default Value 0
Options (Default) Unknown mode (0)      
  2-state switch mode (1)      
  3 way switch mode (2)      
  Momentary push button mode (3)      
  Enter automatic identification mode (4)      

122: Get the state of touch panel port

Get the state of touch panel port

Property Value      
Configuration ID config_122_1      
Data Type INTEGER   Default Value 0
Options (Default) the touch panel is not connected. (0)      
  the touch panel is connected (5)      

123: Set the control destination for external switch S1

Set the control destination for external switch S1

Property Value      
Configuration ID config_123_1      
Data Type INTEGER   Default Value 3
Options control the output loads of itself (1)      
  control the other nodes (2)      
  (Default) control the output loads of itself and other nodes (3)      

124: Set the control destination for external switch S2

Set the control destination for external switch S2

Property Value      
Configuration ID config_124_1      
Data Type INTEGER   Default Value 3
Options control the output loads of itself (1)      
  control the other nodes (2)      
  (Default) control the output loads of itself and other nodes (3)      

125: Set the default dimming rate

The value range is 1 to 255 seconds

Property Value
Configuration ID config_125_1
Data Type INTEGER
Range 1 to 255
Default Value 255

128: Get the current working mode

Get the current working mode

Property Value      
Configuration ID config_128_1      
Data Type INTEGER   Default Value 0
Options (Default) Unknown working mode (0)      
  2-wire mode (1)      
  3-wire mode (2)      

129: Set the dimming principle

Set the dimming principle

Property Value      
Configuration ID config_129_1      
Data Type INTEGER   Default Value 1
Options Trailing edge mode (0)      
  (Default) Leading edge mode (1)      

130: To get what type of load the Dimmer is connected to

To get what type of load the Dimmer is connected to.

Property Value      
Configuration ID config_130_1      
Data Type INTEGER   Default Value 0
Options (Default) Unknown load (0)      
  Resistive load (1)      
  Capacitive load (2)      
  Inductive load (3)      

131: Set the min brightness level that the load can reach to

Set the min brightness level that the load can reach to

Property Value
Configuration ID config_131_1
Data Type INTEGER
Range 0 to 99
Default Value 99

132: Set the max brightness level that the load can reach to

Set the max brightness level that the load can reach to

Property Value
Configuration ID config_132_1
Data Type INTEGER
Range 0 to 99
Default Value 99

249: Set the recognition way of load

Set the recognition way of load

Property Value      
Configuration ID config_249_1      
Data Type INTEGER   Default Value 2
Options Never recognize the load when power on (0)      
  Only recognize once when first power on (1)      
  (Default) Recognize the load once power on (2)      

252: Lock/unlock configuration parameters

Lock/unlock configuration parameters

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options (Default) Unlock (0)      
  Lock (1)      

255: Reset the Nano Dimmer

Reset the Nano Dimmer

Property Value      
Configuration ID config_255_4      
Data Type INTEGER   Default Value 0
Options (Default) factory default (0)      
  factory default and remove (1431655765)      

100: Reset 101-103 to default

Reset parameters 101-103 to default values

Property Value      
Configuration ID config_100_1_wo      
Data Type INTEGER   Default Value 0
Options Reset the parameter 101-103 (0)      

110: Reset 111-113 to default

Reset parameters 111-113 to default values

Property Value      
Configuration ID config_110_1_wo      
Data Type INTEGER   Default Value 0
Options Reset the parameter 111-113 (0)      

120: Configure the external switch mode for S1

Configure the external switch mode for S1

Property Value      
Configuration ID config_120_1_wo      
Data Type INTEGER   Default Value 0
Options (Default) Unknown mode (0)      
  2-state switch mode (1)      
  3 way switch mode (2)      
  Momentary push button mode (3)      
  Enter automatic identification mode (4)      

1: Z-Wave Plus Lifeline

Z-Wave Plus Lifeline

Overview

Z-Wave Plus Lifeline. When the load state of Nano Dimmer (on/off/dim the load ) is changed, the Hail CC, Switch Multilevel Report and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Forward

Overview

Forward the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Switch all to the associated nodes in Group 2 when the Nano Dimmer receives the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Switch all commands from main controller.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Send Basic Set (Group 3) Sw 1

Overview

Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Send Basic Set (Group 3) Sw 2

Overview

Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.