ZW112 Door/Window Sensor 6

This describes the Z-Wave device ZW112, manufactured by AEON Labs with the thing type UID of aeon_zw112_00_000.

Door/Window Sensor 6

Overview

Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window’s open/close in real time. 
It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. 
It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.

Inclusion Information

Turn the primary controller into inclusion mode, short press the product’s Action Button that you can find in the back of the product. 

Exclusion Information

Turn the primary controller into exclusion mode, short press the product’s Action Button that you can find in back of the product. 

Wakeup Information

Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. 

Channels

The following table summarises the channels available for the ZW112 Door/Window Sensor 6.

Channel Channel Id Channel Type UID Category Item Type
Door Sensor sensor_door sensor_door Door Contact
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW112 Door/Window Sensor 6. Detailed information on each parameter can be found below.

Parameter Description
1: Value that will be sent on open/close events  
39: Low battery threshold (10% to 50%) The value the sensor will use to determine a low battery level
101: Low battery voltage check Enable or disables the low battery voltage check
111: Low battery voltage check time Sets the value of the interval for the low battery check time (in seconds)
121: Reporting mode on open/close event  
252: Lock/Unlock all configuration parameters  
255: Reset sensor to factory default and remove from network Reset sensor to factory default and remove from network
1: Lifeline Sends sensor report as configured in parameter 121 when the sensor is triggered

1: Value that will be sent on open/close events

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options On for opened, Off for closed (0)      
  Off for opened, On for closed (1)      

39: Low battery threshold (10% to 50%)

The value the sensor will use to determine a low battery level

Property Value
Configuration ID config_39_1
Data Type INTEGER
Range 10 to 50
Default Value 20

101: Low battery voltage check

Enable or disables the low battery voltage check

Property Value      
Configuration ID config_101_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

111: Low battery voltage check time

Sets the value of the interval for the low battery check time (in seconds)

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 240 to 134217727
Default Value 86640

121: Reporting mode on open/close event

Property Value      
Configuration ID config_121_1      
Data Type INTEGER   Default Value 1
Options Send nothing (0)      
  Send Basic Set CC (1)      
  Send Sensor Binary Report CC (2)      
  Send Basic Set CC and Sensor Binary Report CC (3)      

252: Lock/Unlock all configuration parameters

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Unlock (0)      
  Lock (1)      

255: Reset sensor to factory default and remove from network

Reset sensor to factory default and remove from network

Overview

Writing  1431655765 to this parameter will reset to factory default and the sensor will be removed from network.

If 1 byte is sent with a value of 0, then the senor will be reset to factory default, but the sensor will not be removed from the network.

Property Value
Configuration ID config_255_4_wo
Data Type INTEGER
Range to
Default Value 1

1: Lifeline

Sends sensor report as configured in parameter 121 when the sensor is triggered

Overview

1-5 nodes

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.