ZW116 Aeotec Nano Switch

This describes the Z-Wave device ZW116, manufactured by AEON Labs with the thing type UID of aeon_zw116_00_000.

Aeotec Nano Switch

Overview

Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status.
It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch.
The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Channels

The following table summarises the channels available for the ZW116 Aeotec Nano Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm (power) alarm_power alarm_power Door Switch
Alarm (heat) alarm_heat alarm_heat   Switch
Clock Time Offset time_offset time_offset Temperature Number

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW116 Aeotec Nano Switch. Detailed information on each parameter can be found below.

Parameter Description
3: Current Overload Protection Current Overload Protection
4: Overheat protection Overheat protection
9: Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT) Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)
20: Output status after re-power Configure the output status after re-power on it
80: Group 1 notifications Group 1 notifications when the state of Nano Switch’s load is changed
81: Group 3 notifications Notification to sent for Group 3 when using the external switch 1
82: Group 4 notifications Notification to sent for Group 4 when using the external switch 2
83: Configure the state of LED Configure the state of LED when it is in 3 modes
84: Night light mode LED state Set the ON/OFF time of the LED when it is in Night light mode
86: Set appointment 1 Set the ON time of output load.
87: Set appointment 2 Set the OFF time of output load
90: Enables/disables parameter 91 and 92 Enables/disables parameter 91 and 92
91: Set the threshold value of wattage Threshold change in wattage (in terms of wattage) to induce an automatic report
92: Set the threshold value of wattage Threshold percentage change in wattage for an automatic report
101: Set group 1 reports To set which reports need to be sent in Report group 1.
102: Set group 2 reports To set which reports need to be sent in Report group 2.
103: Set group 3 reports To set which reports need to be sent in Report group 3.
110: Reset the parameter 111-113 Set parameter 111-113 to default value.
111: Interval for automatic report group 1. Set the interval of automatic report for Report group 1.
112: Interval for automatic report group 2 Set the interval of automatic report for Report group 2.
113: Interval for automatic group 3 report Set the interval of automatic report for Report group 3
120: External switch mode for S1 Configure the external switch mode for S1
121: External switch mode for S2 Configure the external switch mode for S2
122: Control destination of external switch Set the control destination for external switch
252: Lock/unlock configuration parameters Lock/unlock configuration parameters
255: Reset the Nano Switch  
100: Set parameter 101-103 to default value Reset the parameter 101-103
100: Set parameter 101-103 to default value Reset the parameter 101-103
1: Z-Wave Plus Lifeline  
2: Forward Group 2  
3: Send Basic Set to Group 3  

3: Current Overload Protection

Current Overload Protection

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  (Default) Enable (1)      

4: Overheat protection

Overheat protection

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options (Default) Disable (0)      
  Enable (1)      

9: Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)

Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)

Overview

Send SENSOR_MULTILEVEL_REPORT at this interval

0 means to not send

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 255
Default Value 0

20: Output status after re-power

Configure the output status after re-power on it

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options Last status (0)      
  Always on (1)      
  Always off (2)      

80: Group 1 notifications

Group 1 notifications when the state of Nano Switch’s load is changed

Overview

To set which notification would be sent to the associated devices (Group 1) when the state of Nano Switch’s load is changed.

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 3
Options Send Nothing (0)      
  Send Hail CC (1)      
  Send Basic Report CC (2)      
  Send Hail CC when using the manual switch to change the load (3)      

81: Group 3 notifications

Notification to sent for Group 3 when using the external switch 1

Overview

To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads.

Property Value      
Configuration ID config_81_1      
Data Type INTEGER   Default Value 1
Options Send Nothing (0)      
  Send Basic Set CC (1)      

82: Group 4 notifications

Notification to sent for Group 4 when using the external switch 2

Overview

To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads.

Property Value      
Configuration ID config_82_1      
Data Type INTEGER   Default Value 1
Options Send Nothing (0)      
  Send Basic Set CC (1)      

83: Configure the state of LED

Configure the state of LED when it is in 3 modes

Overview

Configure the state of LED when it is in 3 modes (Energy mode, Momentary indicate mode, Night light mode)

Property Value      
Configuration ID config_83_1      
Data Type INTEGER   Default Value 0
Options Energy mode. The LED will follow the status (on/off) (0)      
  Momentary indicate mode (1)      
  Night light mode. The LED will remain ON state (2)      

84: Night light mode LED state

Set the ON/OFF time of the LED when it is in Night light mode

Overview

0 to 60 The minute time of OFF 256 to 316 The hour time of OFF 65536 to 65596 The minute time of ON 16777216 to 16777276 The hour time of ON

Property Value
Configuration ID config_84_4
Data Type INTEGER
Range 0 to 4294967295
Default Value 301991936

86: Set appointment 1

Set the ON time of output load.

Overview

65536 to 65543 The day value (Mon to Sun) 16777216 Enable the setting. 256 to 316 The hour value of ON time 16777215 Disable the setting. 0 to 60 The minute value of ON time

Property Value
Configuration ID config_86_4
Data Type INTEGER
Range 0 to 4294967295
Default Value 8327680

87: Set appointment 2

Set the OFF time of output load

Overview

256 to 316 The hour value of ON time 65536 to 65543 The day value (Mon to Sun) 16777215 Disable the setting. 0 to 60 The minute value of ON time 16777216 Enable the setting.

Property Value
Configuration ID config_87_4
Data Type INTEGER
Range 0 to 8327680
Default Value 8327680

90: Enables/disables parameter 91 and 92

Enables/disables parameter 91 and 92

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options (Default) Disable (0)      
  Enable (1)      

91: Set the threshold value of wattage

Threshold change in wattage (in terms of wattage) to induce an automatic report

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

92: Set the threshold value of wattage

Threshold percentage change in wattage for an automatic report

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 5

101: Set group 1 reports

To set which reports need to be sent in Report group 1.

Property Value      
Configuration ID config_101_4      
Data Type INTEGER   Default Value 0
Options Send Meter Report of energy (kWh) (1)      
  Send Meter Report of wattage (W) (2)      
  Send Meter Report of voltage (V) (4)      
  Send Meter Report of current (A) (8)      

102: Set group 2 reports

To set which reports need to be sent in Report group 2.

Property Value      
Configuration ID config_102_4      
Data Type INTEGER   Default Value 0
Options Send Meter Report of energy (kWh) (1)      
  Send Meter Report of wattage (W) (2)      
  Send Meter Report of voltage (V) (4)      
  Send Meter Report of current (A) (8)      

103: Set group 3 reports

To set which reports need to be sent in Report group 3.

Property Value      
Configuration ID config_103_4      
Data Type INTEGER   Default Value 0
Options Send Meter Report of voltage (V) (1)      
  Send Meter Report of current (A) (2)      
  Send Meter Report of wattage (W) (4)      
  Send Meter Report of energy (kWh) (8)      

110: Reset the parameter 111-113

Set parameter 111-113 to default value.

Property Value
Configuration ID config_110_1
Data Type INTEGER
Range 0 to 255
Default Value 0

111: Interval for automatic report group 1.

Set the interval of automatic report for Report group 1.

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 600

112: Interval for automatic report group 2

Set the interval of automatic report for Report group 2.

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 600

113: Interval for automatic group 3 report

Set the interval of automatic report for Report group 3

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 600

120: External switch mode for S1

Configure the external switch mode for S1

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 0
Options Enter automatic identification mode (0)      
  2-state switch mode (1)      
  3 way switch mode (2)      
  Momentary push button mode (3)      

121: External switch mode for S2

Configure the external switch mode for S2

Property Value      
Configuration ID config_121_1      
Data Type INTEGER   Default Value 0
Options Enter automatic identification mode (0)      
  2-state switch mode (1)      
  3 way switch mode (2)      
  Momentary push button mode (3)      

122: Control destination of external switch

Set the control destination for external switch

Property Value      
Configuration ID config_122_1      
Data Type INTEGER   Default Value 3
Options control the output loads of itself (1)      
  control the other nodes (2)      
  control the output loads of itself and other nodes (3)      

252: Lock/unlock configuration parameters

Lock/unlock configuration parameters

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Unlock (0)      
  Lock (1)      

255: Reset the Nano Switch

Property Value      
Configuration ID config_255_4      
Data Type INTEGER   Default Value 0
Options (Default) Reset all configuration parameters (0)      
  Reset and remove from network (1431655765)      

100: Set parameter 101-103 to default value

Reset the parameter 101-103

Property Value
Configuration ID config_100_1_wo
Data Type INTEGER
Range to
Default Value 0

100: Set parameter 101-103 to default value

Reset the parameter 101-103

Property Value
Configuration ID config_100_1_wo
Data Type INTEGER
Range to
Default Value 0

1: Z-Wave Plus Lifeline

Overview

When the load state of Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Forward Group 2

Overview

Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller.
(E.g. Send/forward Basic Set to control the other nodes in association Group 2)

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Send Basic Set to Group 3

Overview

Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated.
Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.