ZW117 Range Extender 6

This describes the Z-Wave device ZW117, manufactured by AEON Labs with the thing type UID of aeon_zw117_00_000.

Range Extender 6

Channels

The following table summarises the channels available for the ZW117 Range Extender 6.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Color Control color_color color_color   Color
Color Temperature color_temperature color_temperature ColorLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW117 Range Extender 6. Detailed information on each parameter can be found below.

Parameter Description
33: RGB value Set the RGB value of the LED for the quality test of the LED diode.
82: Default status of the LED Set the default status of the LED when the Range Extender relays Z-Wave message.
200: Partner ID  
252: Enable/disable the Configuration to be locked  
254: Device Tag.  
255: Reset to factory default Reset to factory default settings and removed from the z-wave network
255: Reset configuration Reset all configuration parameters to factory default settings
1: Group 1 Lifeline
2: Group 2 Retransmit

33: RGB value

Set the RGB value of the LED for the quality test of the LED diode.

Property Value      
Configuration ID config_33_3_00000021      
Data Type INTEGER   Default Value 2
Options Reserved (1)      
  Red value (2)      
  Green value (3)      
  Blue value (4)      

82: Default status of the LED

Set the default status of the LED when the Range Extender relays Z-Wave message.

Property Value      
Configuration ID config_82_1_00000052      
Data Type INTEGER   Default Value 0
Options The green LED remains On for 2 seconds (0)      
  Off (1)      

200: Partner ID

Property Value      
Configuration ID config_200_1_000000C8      
Data Type INTEGER   Default Value 0
Options Aeon Labs Standard Product (0)      
  others (1)      

252: Enable/disable the Configuration to be locked

Property Value      
Configuration ID config_252_1_000000FC      
Data Type INTEGER   Default Value 0
Options disable (0)      
  enable (1)      

254: Device Tag.

Property Value
Configuration ID config_254_2_000000FE
Data Type INTEGER
Range 0 to 65535
Default Value 0

255: Reset to factory default

Reset to factory default settings and removed from the z-wave network

Property Value      
Configuration ID config_255_4_000000FF_wo      
Data Type INTEGER   Default Value 1
Options Reset to factory default (1431655765)      

255: Reset configuration

Reset all configuration parameters to factory default settings

Property Value      
Configuration ID config_255_1_000000FF_wo      
Data Type INTEGER   Default Value 1
Options Reset configuration (0)      

1: Group 1

Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Retransmit

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.