ZW120 Door/Window sensor Gen5

This describes the Z-Wave device ZW120, manufactured by AEON Labs with the thing type UID of aeon_zw120_00_000.

Door/Window sensor Gen5

Channels

The following table summarises the channels available for the ZW120 Door/Window sensor Gen5.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (general) alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW120 Door/Window sensor Gen5. Detailed information on each parameter can be found below.

Parameter Description
1: Which value of the Sensor Binary Report or Basic Set will be sent when the Magnet is triggered On/Off.  
2: Enable wake up 10 minutes when re-power on the sensor Default setting: Disable
3: Basic Set Report Which value of the Basic Set will be sent when the door is Opened/Closed
39: Set the low battery value. 10% to 50%
111: Set the interval time of low battery checking. Minimum interval is 4 minutes, Range is 0 to 2147483647
121: Report type To configure which sensor report will be sent when the Sensor is triggered Opened/Closed. …
255: Reset To Factory Defaults.  
1: Group 1  

1: Which value of the Sensor Binary Report or Basic Set will be sent when the Magnet is triggered On/Off.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options On=Sensor Binary Report/Basic Set 0xFF; Off=Sensor Binary Report/Basic (0)      
  On=Sensor Binary Report/Basic Set 0x00; Off=Sensor Binary Report/Basic (1)      

2: Enable wake up 10 minutes when re-power on the sensor

Default setting: Disable

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

3: Basic Set Report

Which value of the Basic Set will be sent when the door is Opened/Closed

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Open: 0xFF, Close: 0x00 (0)      
  Open: 0x00, Close: 0xFF (1)      

39: Set the low battery value.

10% to 50%

Property Value
Configuration ID config_39_1
Data Type INTEGER
Range 10 to 50
Default Value 10

111: Set the interval time of low battery checking.

Minimum interval is 4 minutes, Range is 0 to 2147483647

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 86640

121: Report type

To configure which sensor report will be sent when the Sensor is triggered Opened/Closed. Bitsets: 0->Battery report, 4->Sensor Binary, 8->Basic Set, Default setting: 0x00000100 (Basic Set).Ideal Setting for OZW is 17 (Sensor Binary and Battery Report).

Property Value
Configuration ID config_121_4
Data Type INTEGER
Range 0 to 65535
Default Value 1

255: Reset To Factory Defaults.

Property Value      
Configuration ID config_255_4      
Data Type INTEGER   Default Value 0
Options Reset to factory default setting (0)      
  Normal (1)      
  Reset to factory default (1431655765)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.