ZW129 Dual Wallmote

This describes the Z-Wave device ZW129, manufactured by AEON Labs with the thing type UID of aeon_zw129_00_000.

Dual Wallmote

Channels

The following table summarises the channels available for the ZW129 Dual Wallmote.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW129 Dual Wallmote. Detailed information on each parameter can be found below.

Parameter Description
1: Touch sound Enable/disable the touch sound.
2: Touch vibration Enable/disable the touch vibration.
3: Button slide Enable/disable the function of button slide.
4: Notification report Which notification to be sent to the associated devices.
39: Low battery value Set the low battery value
255: Reset the WallMote Quad Reset the WallMote Quad to factory default.
1: Z-Wave Plus Lifeline Central Scene Notification
2: Button 1 basic On/off control via button 1
3: Button 1 multilevel Dim control via button 1
4: Button 2 basic On/off control via button 2
5: Button 2 multilevel Dim control via button 2

1: Touch sound

Enable/disable the touch sound.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

2: Touch vibration

Enable/disable the touch vibration.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

3: Button slide

Enable/disable the function of button slide.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

4: Notification report

Which notification to be sent to the associated devices.

Overview

To set which notification would be sent to the associated devices (Group 1) when pressing the buttons. When the parameter is set to 3, slide functionality on the buttons is activated.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Central scene (1)      
  Central scene and config (3)      

39: Low battery value

Set the low battery value

Property Value
Configuration ID config_39_1
Data Type INTEGER
Range 0 to 50
Default Value 5

255: Reset the WallMote Quad

Reset the WallMote Quad to factory default.

Property Value      
Configuration ID config_255_4_wo      
Data Type INTEGER   Default Value 0
Options Reset to factory default (0)      
  Reset and remove (1431655765)      

1: Z-Wave Plus Lifeline

Central Scene Notification

Overview

When touching the Button 1 to 4, the Central Scene Notificcation command will be sent to the associated node (1) in Association group 1.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Button 1 basic

On/off control via button 1

Overview

When touching the Button 1, the Basic Set command will be sent to the associated nodes in Association group 2.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Button 1 multilevel

Dim control via button 1

Overview

When touching the Button 1, the Multilevel Switch Set command will be sent to the associated nodes in Association group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Button 2 basic

On/off control via button 2

Overview

When touching the Button 2, the Basic Set command will be sent to the associated nodes in Association group 4.

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Button 2 multilevel

Dim control via button 2

Overview

When touching the Button 2, the Multilevel Switch Set command will be sent to the associated nodes in Association group 5.

Property Value
Configuration ID group_5
Data Type TEXT
Range to