ZW130 WallMote Quad

This describes the Z-Wave device ZW130, manufactured by AEON Labs with the thing type UID of aeon_zw130_00_000.

WallMote Quad

Overview

Aeotec WallMote Quad is an intelligent Z-Wave remote controller that mounted on a wall. It has 4 touch buttons that you can easily control the Z-Wave devices in your home network via touching, long pressing or sliding the button areas. Its surface has a RGB LED to indicate the button actions also accompanied by touch beep and vibration. The WallMote Quad is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Inclusion Information

Including WallMote Quad as a non-secure device:

If you want your WallMote Quad as a non-security device in your Z-wave network, you just need to press the Action Button once on WallMote Quad when you use a controller/gateway to add/include it. The green LED will be on for 2 seconds and then the orange LED will fast blink for 10 minutes (if the WallMote Quad does not receive the Wake Up No More Info command from primary Controller) to indicate the inclusion is successful

Including WallMote Quad as a secure device:

In order to take full advantage of all functionality the WallMote Quad, you may want your WallMote Quad is a security device that uses secure/encrypted message to communicate in Z-wave network, so a security enabled controller/gateway is needed for the WallMote Quad to be used as a security device. You need to press the WallMote Quad’s Action Button 2 times within 1 second when your security controller/gateway starts the network inclusion. The blue LED will be on for 2 seconds and then the orange LED will fast blink for 10 minutes (if the WallMote Quad does not receive the Wake Up No More Info command from primary Controller) to indicate the inclusion is successful.

Exclusion Information

Your WallMote Quad can be removed from your Z-Wave network at any time. You’ll need to use your Z-Wave network’s main controller/ gateway. To do this, please refer to the part of their respective manuals that tell you how to remove devices from your network.

  1. Put your primary controller into device removal mode.
  2. Unlock your WallMote Quad from the Back Mount plate and take the WallMote Quad unit near to your primary controller.
  3. Press the Action Button on your WallMote Quad.

If your WallMote Quad is successfully removed from the Z-Wave network, the LED will become a colourful gradient for a few seconds and then turn off. If the removing was unsuccessful, the red LED will be solid for 2 seconds and then turn off, repeat the above steps.

Wakeup Information

In order to send your WallMote Quad new configuration commands from your Z-Wave controller or gateway, it will need to be woken up.

Remove your WallMote Quad unit from its Back Mounting Plate, press and hold the Action Button for 3 seconds(the buzzer chirp once and the orange LED will be ON) on the back of the WallMote Quad unit and then release it. This will trigger and send a wake up notification command to your controller/gateway, then your WallMote Quad will wake up for 10 minutes and the orange LED will fast blink while it is awake (if the WallMote Quad does not receive the Wake Up No More Info from the primary Controller).

Channels

The following table summarises the channels available for the ZW130 WallMote Quad.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
Alarm (power) alarm_power alarm_power Door Switch
  battery-level system.battery-level    
Scene Number 1 scene_number1 scene_number   Number
Scene Number 2 scene_number2 scene_number   Number
Scene Number 3 scene_number3 scene_number   Number
Scene Number 4 scene_number4 scene_number   Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW130 WallMote Quad. Detailed information on each parameter can be found below.

Parameter Description
1: Touch sound Enable/disable the touch sound.
2: Touch vibration Enable/disable the touch vibration.
3: Button slide Enable/disable the function of button slide.
4: Notification report Which notification to be sent to the associated devices.
39: Low battery value Set the low battery value
255: Reset the WallMote Quad Reset the WallMote Quad to factory default.
1: Lifeline Central Scene Notification
2: Button 1 basic On/off control via button 1
3: Button 1 multilevel Dim control via button 1
4: Button 2 basic On/off control via button 2
5: Button 2 multilevel Dim control via button 2
6: Button 3 basic On/off control via button 3
7: Button 3 multilevel Dim control via button 3
8: Button 4 basic On/off control via button 4
9: Button 4 multilevel Dim control via button 4

1: Touch sound

Enable/disable the touch sound.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

2: Touch vibration

Enable/disable the touch vibration.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

3: Button slide

Enable/disable the function of button slide.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

4: Notification report

Which notification to be sent to the associated devices.

Overview

To set which notification would be sent to the associated devices (Group 1) when pressing the buttons. When the parameter is set to 3, slide functionality on the buttons is activated.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Central scene (1)      
  Central scene and config (3)      

39: Low battery value

Set the low battery value

Property Value
Configuration ID config_39_1
Data Type INTEGER
Range 0 to 50
Default Value 5

255: Reset the WallMote Quad

Reset the WallMote Quad to factory default.

Property Value      
Configuration ID config_255_4_wo      
Data Type INTEGER   Default Value 0
Options Reset to factory default (0)      
  Reset and remove (1431655765)      

1: Lifeline

Central Scene Notification

Overview

When touching the Button 1 to 4, the Central Scene Notificcation command will be sent to the associated node (1) in Association group 1.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Button 1 basic

On/off control via button 1

Overview

When touching the Button 1, the Basic Set command will be sent to the associated nodes in Association group 2.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Button 1 multilevel

Dim control via button 1

Overview

When touching the Button 1, the Multilevel Switch Set command will be sent to the associated nodes in Association group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Button 2 basic

On/off control via button 2

Overview

When touching the Button 2, the Basic Set command will be sent to the associated nodes in Association group 4.

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Button 2 multilevel

Dim control via button 2

Overview

When touching the Button 2, the Multilevel Switch Set command will be sent to the associated nodes in Association group 5.

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Button 3 basic

On/off control via button 3

Overview

When touching the Button 3, the Basic Set command will be sent to the associated nodes in Association group 6.

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: Button 3 multilevel

Dim control via button 3

Overview

When touching the Button 3, the Multilevel Switch Set command will be sent to the associated nodes in Association group 7.

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: Button 4 basic

On/off control via button 4

Overview

When touching the Button 4, the Basic Set command will be sent to the associated nodes in Association group 8.

Property Value
Configuration ID group_8
Data Type TEXT
Range to

9: Button 4 multilevel

Dim control via button 4

Overview

When touching the Button 4, the Multilevel Switch Set command will be sent to the associated nodes in Association group 9.

Property Value
Configuration ID group_9
Data Type TEXT
Range to