ZW132 Dual Nano Switch with Energy Metering

This describes the Z-Wave device ZW132, manufactured by AEON Labs with the thing type UID of aeon_zw132_00_000.

Dual Nano Switch with Energy Metering

Channels

The following table summarises the channels available for the ZW132 Dual Nano Switch with Energy Metering.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm (power) alarm_power alarm_power Door Switch
Alarm (heat) alarm_heat alarm_heat   Switch
Clock Time Offset time_offset time_offset Temperature Number
Switch 1 switch_binary1 switch_binary Switch Switch
Remove switch_binary1 switch_binary Switch Switch
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Remove switch_binary2 switch_binary Switch Switch
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW132 Dual Nano Switch with Energy Metering. Detailed information on each parameter can be found below.

Parameter Description
3: Current Overload Protection. Current Overload Protection.
4: Overheat protection Overheat protection
20: Configure the output status after re-power on it. Configure the output status after re-power on it.
80: Group 1 notifications To set which notification would be sent to the associated devices (Group 1)
81: Group 3 notifications To set which notification would be sent to association group 3
82: Group 4 notifications To set which notification would be sent to association group 4
90: Enables/disables parameter 91 and 92 below: Enables/disables parameter 91 and 92 below:
91: Set the threshold value of wattage. Set the threshold value of wattage.
92: Set the threshold value of wattage. Set the threshold value of wattage.
101: Set group 1 reports To set which reports need to be sent in Report group 1
102: To set which reports need to be sent in Report group 2. To set which reports need to be sent in Report group 2.
103: To set which reports need to be sent in Report group 3 To set which reports need to be sent in Report group 3.
111: Set the interval of automatic report for Report group 1. Set the interval of automatic report for Report group 1.
112: Set the interval of automatic report for Report group 2 Set the interval of automatic report for Report group 2.
113: Set the interval of automatic report for Report group 2. Set the interval of automatic report for Report group 2.
120: Configure the external switch mode for S1 Configure the external switch mode for S1
121: Configure the external switch mode for S2. Configure the external switch mode for S2.
122: Set the control destination for external switch Set the control destination for external switch
252: Lock/unlock configuration parameters Lock/unlock configuration parameters
255: Reset the Dual Nano Switch Reset the Dual Nano Switch
100: Set parameter 101-103 to default value Reset the parameter 101-103
110: Set parameter 111-113 to default value. Set parameter 111-113 to default value.
1: Lifeline When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and…
2: Forward the Basic Set Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch …
3: Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switc…
4: Send Basic Set Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the …

3: Current Overload Protection.

Current Overload Protection.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

4: Overheat protection

Overheat protection

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

20: Configure the output status after re-power on it.

Configure the output status after re-power on it.

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options Last status (0)      
  Always on (1)      
  Always off (2)      

80: Group 1 notifications

To set which notification would be sent to the associated devices (Group 1)

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options Send Nothing (0)      
  Send Hail CC (1)      
  Send Basic CC report (2)      
  Send Hail CC when using the manual switch (3)      

81: Group 3 notifications

To set which notification would be sent to association group 3

Property Value      
Configuration ID config_81_1      
Data Type INTEGER   Default Value 1
Options Send Nothing (0)      
  Send Basic Set CC (1)      

82: Group 4 notifications

To set which notification would be sent to association group 4

Property Value      
Configuration ID config_82_1      
Data Type INTEGER   Default Value 1
Options Send Nothing (0)      
  Send Basic Set CC (1)      

90: Enables/disables parameter 91 and 92 below:

Enables/disables parameter 91 and 92 below:

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

91: Set the threshold value of wattage.

Set the threshold value of wattage.

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

92: Set the threshold value of wattage.

Set the threshold value of wattage.

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 5

101: Set group 1 reports

To set which reports need to be sent in Report group 1

Property Value      
Configuration ID config_101_4      
Data Type INTEGER   Default Value 0
Options Send Meter Report of energy (kWh) (1)      
  Send Meter Report of wattage (W) (2)      
  Send Meter Report of voltage (V) (4)      
  Send Meter Report of current (A) (8)      
  Send Multi Channel Meter Report of wattage (W) on Channel 1 (256)      
  Send Multi Channel Meter Report of wattage (W) on Channel 2 (512)      
  Send Multi Channel Meter Report of energy (kWh) on Channel 1 (2048)      
  Send Multi Channel Meter Report of energy (kWh) on Channel 2 (4096)      
  Send Multi Channel Meter Report of voltage (V) on Channel 1 (65536)      
  Send Multi Channel Meter Report of voltage (V) on Channel 2 (131072)      
  Send Multi Channel Meter Report of current (A) on Channel 1 (524288)      
  Send Multi Channel Meter Report of current (A) on Channel 2 (1048576)      

102: To set which reports need to be sent in Report group 2.

To set which reports need to be sent in Report group 2.

Property Value      
Configuration ID config_102_1      
Data Type INTEGER   Default Value 0
Options Send Meter Report of energy (kWh) (1)      
  Send Meter Report of wattage (W) (2)      
  Send Meter Report of voltage (V) (4)      
  Send Meter Report of current (A) (8)      
  Send Multi Channel Meter Report of wattage (W) on Channel 1 (256)      
  Send Multi Channel Meter Report of wattage (W) on Channel 2 (512)      
  Send Multi Channel Meter Report of energy (kWh) on Channel 1 (2048)      
  Send Multi Channel Meter Report of energy (kWh) on Channel 2 (4096)      
  Send Multi Channel Meter Report of voltage (V) on Channel 1 (65536)      
  Send Multi Channel Meter Report of voltage (V) on Channel 2 (131072)      
  Send Multi Channel Meter Report of current (A) on Channel 1 (524288)      
  Send Multi Channel Meter Report of current (A) on Channel 2 (1048576)      

103: To set which reports need to be sent in Report group 3

To set which reports need to be sent in Report group 3.

Property Value      
Configuration ID config_103_1      
Data Type INTEGER   Default Value 0
Options Send Meter Report of voltage (V) (1)      
  Send Meter Report of current (A) (2)      
  Send Meter Report of wattage (W) (4)      
  Send Meter Report of energy (kWh) (8)      
  Send Multi Channel Meter Report of wattage (W) on Channel 1 (256)      
  Send Multi Channel Meter Report of wattage (W) on Channel 2 (512)      
  Send Multi Channel Meter Report of energy (kWh) on Channel 1 (2048)      
  Send Multi Channel Meter Report of energy (kWh) on Channel 2 (4096)      
  Send Multi Channel Meter Report of voltage (V) on Channel 1 (65536)      
  Send Multi Channel Meter Report of voltage (V) on Channel 2 (131072)      
  Send Multi Channel Meter Report of current (A) on Channel 1 (524288)      
  Send Multi Channel Meter Report of current (A) on Channel 2 (1048576)      

111: Set the interval of automatic report for Report group 1.

Set the interval of automatic report for Report group 1.

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 10

112: Set the interval of automatic report for Report group 2

Set the interval of automatic report for Report group 2.

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 600

113: Set the interval of automatic report for Report group 2.

Set the interval of automatic report for Report group 2.

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 600

120: Configure the external switch mode for S1

Configure the external switch mode for S1

Property Value      
Configuration ID config_120_1      
Data Type INTEGER   Default Value 0
Options Enter automatic identification mode (0)      
  2-state switch mode (1)      
  3 way switch mode (2)      
  Momentary push button mode (3)      

121: Configure the external switch mode for S2.

Configure the external switch mode for S2.

Property Value      
Configuration ID config_121_1      
Data Type INTEGER   Default Value 0
Options Enter automatic identification mode (0)      
  2-state switch mode (1)      
  3 way switch mode (2)      
  Momentary push button mode (3)      

122: Set the control destination for external switch

Set the control destination for external switch

Property Value      
Configuration ID config_122_1      
Data Type INTEGER   Default Value 3
Options control the output loads of itself. (1)      
  control the other nodes (2)      
  control the output loads of itself and other nodes. (3)      

252: Lock/unlock configuration parameters

Lock/unlock configuration parameters

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options Unlock (0)      
  Lock (1)      

255: Reset the Dual Nano Switch

Reset the Dual Nano Switch

Property Value      
Configuration ID config_255_4      
Data Type INTEGER   Default Value 0
Options (Default) Reset all configuration parameters (0)      

100: Set parameter 101-103 to default value

Reset the parameter 101-103

Property Value
Configuration ID config_100_1_wo
Data Type INTEGER
Range to
Default Value 0

110: Set parameter 111-113 to default value.

Set parameter 111-113 to default value.

Property Value
Configuration ID config_110_1_wo
Data Type INTEGER
Range to
Default Value 0

1: Lifeline

When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Forward the Basic Set

Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Send Basic Set

(configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated. Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Send Basic Set

Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated. Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.