This describes the Z-Wave device Alarm Sound, manufactured by BeNext with the thing type UID of benext_alarmsound_00_000.

Alarm sound

Channels

The following table summarises the channels available for the Alarm Sound Alarm sound.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the Alarm Sound Alarm sound. Detailed information on each parameter can be found below.

Parameter Description
1: Set to Default Set all configuration values to default values (factory settings)
2: Destination routine on/off Test connection by sending a periodic test. if the device doesn’t react the user will be n…
3: Desitnation routine succes time Time it takes to send a new frame after the last frame has succesfully send
4: Destination routine failed time Time elapsed between failing to end a frame and sending a new frame.
7: Select index sound/light mode The index of the sound mode when a switch binary/basic set frame been received
8: power offline sound/light mode The sound and light mode that will be used when the device gets unplugged.
10: sound/light index 1 Sound/light that will be played when index 1 has been selected
28: sound/light index 2 Sound/light that will be played when index 2 has been selected
46: sound/light index 3 Sound/light that will be played when index 3 has been selected
64: sound/light index 4 Sound/light that will be played when index 4 has been selected
82: sound/light index 5 Sound/light that will be played when index 5 has been selected
100: sound/light index 6 Sound/light that will be played when index 6 has been selected
1: Association group 1 Changes the LED on the device
2: Association group 2 The alarm sound reports it status to the associated devices

1: Set to Default

Set all configuration values to default values (factory settings)

Overview

If value is set to 255 reset to default settings.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 1 to 255
Default Value 1

2: Destination routine on/off

Test connection by sending a periodic test. if the device doesn’t react the user will be notified by a sound.

Overview

0 this is turned off. 1-255 turn it on.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 255

3: Desitnation routine succes time

Time it takes to send a new frame after the last frame has succesfully send

Overview

t(s) = param1 * 6 *60

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 60
Default Value 60

4: Destination routine failed time

Time elapsed between failing to end a frame and sending a new frame.

Overview

t(s) = param1 *60

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 240
Default Value 240

7: Select index sound/light mode

The index of the sound mode when a switch binary/basic set frame been received

Overview

0 to switch off, 1-6 to select light/sound mode.

If value is put higher then 5 the application will read this as 1.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 6
Default Value 1

8: power offline sound/light mode

The sound and light mode that will be used when the device gets unplugged.

Overview

0 to switch off, 1-6 to select light/sound mode.

If value is put higher then 5 the application will read this as 1.

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 6
Default Value 6

10: sound/light index 1

Sound/light that will be played when index 1 has been selected

Overview

Params 10-27 are the values to set the sound/light (this will be set when index 1)

When the configuration is not this size the frame will be ignored.

For the configuration of the light/sound mode i would like to refer to the manual.

Property Value
Configuration ID config_10_18
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

28: sound/light index 2

Sound/light that will be played when index 2 has been selected

Overview

Params 28-45 are the values to set the sound/light (this will be set when index 2)

When the configuration is not this size the frame will be ignored.

For the configuration of the light/sound mode i would like to refer to the manual.

Property Value
Configuration ID config_28_18
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

46: sound/light index 3

Sound/light that will be played when index 3 has been selected

Overview

Params 45-63 are the values to set the sound/light (this will be set when index 3)

When the configuration is not this size the frame will be ignored.

For the configuration of the light/sound mode i would like to refer to the manual.

Property Value
Configuration ID config_46_18
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

64: sound/light index 4

Sound/light that will be played when index 4 has been selected

Overview

Params 64-81 are the values to set the sound/light (this will be set when index 4)

When the configuration is not this size the frame will be ignored.

For the configuration of the light/sound mode i would like to refer to the manual.

Property Value
Configuration ID config_64_18
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

82: sound/light index 5

Sound/light that will be played when index 5 has been selected

Overview

Params 82-99 are the values to set the sound/light (this will be set when index 5)

When the configuration is not this size the frame will be ignored.

For the configuration of the light/sound mode i would like to refer to the manual.

Property Value
Configuration ID config_82_18
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

100: sound/light index 6

Sound/light that will be played when index 6 has been selected

Overview

Params 100-117 are the values to set the sound/light (this will be set when index 6)

When the configuration is not this size the frame will be ignored.

For the configuration of the light/sound mode i would like to refer to the manual.

Property Value
Configuration ID config_100_18
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

1: Association group 1

Changes the LED on the device

Overview

When the device receives an binary switch/ basic report, this will update the LED

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Association group 2

The alarm sound reports it status to the associated devices

Overview

- In case the device gets unplugged this shall send Alarm report (code 3, Triggered).

- When the device is connected to the power, this shall send an Alarm report (code 3, off).

- When the device is truned of by clicking on the button, this shall send a Switch binary (off).

- When the device gets unplugged the standard “power offline” sound is on, the device will send a Switch binary report (on).

When the Device is connected to a powersupply, the device will say it has connection to the associated devices in group 2. when the connection is succesful the led will be on for 1 second. If the device cannot make a connection the led will blink 6 times. If the led doesn’t go on there is no device in this association group.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.