Energy Switch + Energy Switch +

This describes the Z-Wave device Energy Switch +, manufactured by BeNext with the thing type UID of benext_energyswitch_00_000.

Energy Switch +

Channels

The following table summarises the channels available for the Energy Switch + Energy Switch +.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the Energy Switch + Energy Switch +. Detailed information on each parameter can be found below.

Parameter Description
1: Set to Default If value is set to 0XFF (255), device set to default
2: Amount of decimals If value is set to 1 the info shall be presented with 1 decimal
3: Power Limit The device will shut down when it reaches an amount higher then defined (W)
4: Start up with last known socket status If 0 then the device will always be off, when 1-255 it will emain the last known state
6: Auto report % The value will change when the % is changed.
7: Auto report Watt The value will change when the Watt is changed.
8: Auto report time The time between 2 of the meter rerport
9: Relais delay time The time that needs to pass before the next state change
10: Led indicator The state of the Led compared to the relais state

1: Set to Default

If value is set to 0XFF (255), device set to default

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Amount of decimals

If value is set to 1 the info shall be presented with 1 decimal

Overview

0,1,2,3 amount of decimals. Every Amount higher then 3 shall be printed as 3 decimals.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 3
Default Value 0

3: Power Limit

The device will shut down when it reaches an amount higher then defined (W)

Overview

0 = no power limit.

1-4500 are acceptable values and can be used, everything above the 4500 shall be changed to 4500.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 4500
Default Value 4500

4: Start up with last known socket status

If 0 then the device will always be off, when 1-255 it will emain the last known state

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 255
Default Value 0

6: Auto report %

The value will change when the % is changed.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 10 to 100
Default Value 20

7: Auto report Watt

The value will change when the Watt is changed.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 5 to 255
Default Value 10

8: Auto report time

The time between 2 of the meter rerport

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 10 to 255
Default Value 20

9: Relais delay time

The time that needs to pass before the next state change

Overview

Value * 10 miliseconds

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 255
Default Value 50

10: Led indicator

The state of the Led compared to the relais state

Overview

0 = Indication Led never off

1 = led ON when relais ON

2 = led On when relais OFF

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 2
Default Value 0

Did you spot an error in the above definition or want to improve the content? You can edit the database here.