Heating Control Thermostat for controlling the opentherm protocol

This describes the Z-Wave device Heating Control, manufactured by BeNext with the thing type UID of benext_heatingcontrol_00_000.

Thermostat for controlling the opentherm protocol

Overview

The Heating Control is the central point of your climate environment. You can overwrite the temperature setpoint of your thermostat, and this product also reports information about your thermostat or boiler. For example the room temperature, boiler pressure, modulation level or water temperature.

This product can be simply placed between your thermostat and boiler. The current setup is not changed and therefore you can still use the device as you normally would do. You don’t have to replace your current thermostat.

Note: This product only works if the current communication between your thermostat and boiler uses the standardized modulating protocol Open Therm. If you are not sure whether your thermostat/boiler uses Open Therm, you may find that in the manual of your thermostat/boiler. You can also find it on the internet. You can search for example on ‘Honeywell round clock open therm’.

Channels

The following table summarises the channels available for the Heating Control Thermostat for controlling the opentherm protocol.

Channel Channel Id Channel Type UID Category Item Type
Room temperature sensor_temperature sensor_temperature Temperature Number
Outside temperature sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode benext_heatingcontrol_00_000_thermostat_mode Temperature Number
Heating setpoint thermostat_setpoint_1 thermostat_setpoint Temperature Number
Energy save setpoint thermostat_setpoint_11 thermostat_setpoint Temperature Number

Room temperature

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Outside temperature

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Heating setpoint

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Energy save setpoint

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Heating Control Thermostat for controlling the opentherm protocol. Detailed information on each parameter can be found below.

Parameter Description
1: Set to default Set all configuration values to default values (factory settings)
2: Data request interval Interval of updating data from thermostat and boiler
3: T room update difference Difference of temperature before new update
4: T setpoint update difference Difference in setpoint before new update
5: Unsolicited CRC CRC-16 encapulation
6: Type of 'special' thermostat Type of ‘special’ thermostat if applicable
7: Status auto report Status auto report boiler/thermostat report.
9: Enable/Disable thermostat schedule Enable/Disable thermostat schedule inside the controller
11: Readout manual setpoint thermostat Readout manual setpoint thermostat
1: Group 1 Unsolicited reports

1: Set to default

Set all configuration values to default values (factory settings)

Overview

If 0xFF (255) then set to default

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Reset (255)      

2: Data request interval

Interval of updating data from thermostat and boiler

Overview

The interval in seconds that data is requested (and therefore updated) from the thermostat and boiler. 

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 1 to 255
Default Value 14

3: T room update difference

Difference of temperature before new update

Overview

The value that the room temperature must differ (compared to his previous send value) before an unsolicited room temperature report is send to the associated node. 

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 255
Default Value 1

4: T setpoint update difference

Difference in setpoint before new update

Overview

The value that the temperature setpoint must differ (compared to his previous send value) before an unsolicited temperature setpoint report is send to the associated node. 

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 255
Default Value 5

5: Unsolicited CRC

CRC-16 encapulation

Overview

Configure if the unsolicited reports are send with the CRC-16 encapsulation. Not that the receiving node should support this encapsulation to parse the Z-Wave frame! 

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options Off (0)      
  On (255)      

6: Type of 'special' thermostat

Type of ‘special’ thermostat if applicable

Overview

Type of ‘special’ thermostat. NOTE: when remeha Celcia 20 support is set than any other thermostat cannot be set (!) NOTE2: when Remeha Celcia 20 gives ‘Fout 203’ send cfg value again 

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options No special (0)      
  Remeha Celcia 20 (1)      
  Honeywell (rounded temperatures) (2)      

7: Status auto report

Status auto report boiler/thermostat report.

Overview

Status auto report boiler/thermostat report.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 0
Options Disable boiler/thermostat status messages auto report (0)      
  Enable boiler/thermostat status messages auto report (255)      

9: Enable/Disable thermostat schedule

Enable/Disable thermostat schedule inside the controller

Overview

Enable/Disable thermostat schedule inside the heatingcontroller

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options Disable thermostat schedule (0)      
  Enable thermostat schedule (255)      

11: Readout manual setpoint thermostat

Readout manual setpoint thermostat

Overview

This parameter is used to set the possible manual readout of the setpoint on the thermostat. If the thermostat is manually set to a different mode it is then possible to readout this value if enabled.

(NB. This setting is not in the manual but verified through contacting the service department of BeNext).

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options Readout OFF (0)      
  Readout ON (255)      

1: Group 1

Unsolicited reports

Overview

Every unsolicited report will be sent to the nodes in this group. 

Property Value
Configuration ID group_1
Data Type TEXT
Range to