Molite Movement sensor with temperature and light sensor

This describes the Z-Wave device Molite, manufactured by BeNext with the thing type UID of benext_molite_00_000.

Movement sensor with temperature and light sensor

Channels

The following table summarises the channels available for the Molite Movement sensor with temperature and light sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Molite Movement sensor with temperature and light sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Reset to factory settings Set all configuration values to default values (factory settings).
2: Mode timeout The time used in mode 2 to turn the sensor off. This time will start running as soon as de…
3: Switch off time The switch off time will start running as soon as mode timeout is done. The Motion sensor …
4: sensitivity the sensitivity of the motion circuit
5: The mode The mode that is entered after detection
6: The temperature offset An offset for the temperature.
7: Light table 100 % If a LDR resistance measured lower then this value the returned light percentage is 100%. …
8: Light table 90 % If a LDR resistance measured lower then this value the returned light percentage is 90%. S…
9: Light table 80 % If a LDR resistance measured lower then this value the returned light percentage is 80%. S…
10: Light table 70 % If a LDR resistance measured lower then this value the returned light percentage is 70%. S…
11: Light table 60 % If a LDR resistance measured lower then this value the returned light percentage is 60%. S…
12: Light table 50 % If a LDR resistance measured lower then this value the returned light percentage is 50%. S…
13: Light table 40 % If a LDR resistance measured lower then this value the returned light percentage is 40%. S…
14: Light table 30 % If a LDR resistance measured lower then this value the returned light percentage is 30%. S…
15: Light table 20 % If a LDR resistance measured lower then this value the returned light percentage is 20%. S…
16: Light table 10 % If a LDR resistance measured lower then this value the returned light percentage is 10%. S…
1: Devices to be switched on when motion detected and off after on time  

1: Reset to factory settings

Set all configuration values to default values (factory settings).

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Mode timeout

The time used in mode 2 to turn the sensor off. This time will start running as soon as detection is seen.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 900
Default Value 900

3: Switch off time

The switch off time will start running as soon as mode timeout is done. The Motion sensor is turned on and when movement is detected again. The mode timeout (cfg param 1) will start running all over again. When switch off time is done a basic off message

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 2700
Default Value 2700

4: sensitivity

the sensitivity of the motion circuit

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 127
Default Value 80

5: The mode

The mode that is entered after detection

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 2
Options Mode 1: no detection possible. Battery save mode. (1)      
  Mode 2: normal operation mode: send on after detection and off after g (2)      
  Mode 3: Z-Wave chip is always on to request e.g. version or manufactur (3)      

6: The temperature offset

An offset for the temperature.

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

7: Light table 100 %

If a LDR resistance measured lower then this value the returned light percentage is 100%. See chapter light table for more information.

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 0 to 17
Default Value 17

8: Light table 90 %

If a LDR resistance measured lower then this value the returned light percentage is 90%. See chapter light table for more information.

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 38
Default Value 38

9: Light table 80 %

If a LDR resistance measured lower then this value the returned light percentage is 80%. See chapter light table for more information.

Property Value
Configuration ID config_9_2
Data Type INTEGER
Range 0 to 85
Default Value 85

10: Light table 70 %

If a LDR resistance measured lower then this value the returned light percentage is 70%. See chapter light table for more information.

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 0 to 186
Default Value 186

11: Light table 60 %

If a LDR resistance measured lower then this value the returned light percentage is 60%. See chapter light table for more information.

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 407
Default Value 407

12: Light table 50 %

If a LDR resistance measured lower then this value the returned light percentage is 50%. See chapter light table for more information.

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 891
Default Value 891

13: Light table 40 %

If a LDR resistance measured lower then this value the returned light percentage is 40%. See chapter light table for more information.

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 0 to 1949
Default Value 1949

14: Light table 30 %

If a LDR resistance measured lower then this value the returned light percentage is 30%. See chapter light table for more information.

Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 0 to 4265
Default Value 4265

15: Light table 20 %

If a LDR resistance measured lower then this value the returned light percentage is 20%. See chapter light table for more information.

Property Value
Configuration ID config_15_2
Data Type INTEGER
Range 0 to 9332
Default Value 9332

16: Light table 10 %

If a LDR resistance measured lower then this value the returned light percentage is 10%. See chapter light table for more information.

Property Value
Configuration ID config_16_2
Data Type INTEGER
Range 0 to 20417
Default Value 20417

1: Devices to be switched on when motion detected and off after on time

Property Value
Configuration ID group_1
Data Type TEXT
Range to