Overview
The P1-dongle sends smart meter data wirelessly to your controller, helping you get insight of your consumption and things like the overall yield of your solar panels. The P1-dongle can connect to smart meters that support DSMR (Dutch Smart Meter Reader Protocol) eg. all smart meters with a P1-connector.
LED Status Information
- Ready to install: LED pulse once per second
- Including: LED pulse twice per second
- Excluding: LED pulse three times per 1.5 second
- Include Successful: LED on for one second
- Ready and operating in a Z-Wave network: LED continuously on
- No ready and not included in a Z-Wave network: LED pulse once per second
Inclusion Information
- Put you controller in inclusion mode
- Connect the P1 Dongle to your Smart Meter (use a power source when needed)
- The P1 Dongle will switch to Network Wide Inclusion automatically
Use the button to switch the P1 Dongle to Inclusion (LED pulse twice per second) or Exclusion / Reset (LED pulse three times per 1.5 second) mode
Exclusion Information
- Put your controller and the P1 Dongle in exclusion mode (LED pulse three times per 1.5 second)
- The dongle will exclude from it’s former network and reset to node ID zero
- If the P1 Dongle wasn’t included in a network before, this procedure will act as a node reset
Use the button to switch the P1 Dongle to Inclusion (LED pulse twice per second) or Exclusion / Reset (LED pulse three times per 1.5 second) mode
Channels
The following table summarises the channels available for the P1-dongle P1-dongle.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Gas meter (G_Cubic_Meters) 3 | meter_gas_cubic_meters3 | meter_gas_cubic_meters | Energy | Number |
Device Configuration
The following table provides a summary of the configuration parameters available in the P1-dongle P1-dongle. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
4: Baud Rate | Baud rate: the rate the device sends data between the smart meter and z-wave |
4: Baud Rate
Baud rate: the rate the device sends data between the smart meter and z-wave
Overview
Set BAUD rate value * 100.
Property | Value |
---|---|
Configuration ID | config_4_2 |
Data Type | INTEGER |
Range | 0 to 40000 |
Default Value | 1152 |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.