Tag Reader Tag Reader

This describes the Z-Wave device Tag Reader, manufactured by BeNext with the thing type UID of benext_tagreader_00_000.

Tag Reader

Channels

The following table summarises the channels available for the Tag Reader Tag Reader.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (access) notification_access_control notification_access_control   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the Tag Reader Tag Reader. Detailed information on each parameter can be found below.

Parameter Description
1: Set to Default Set all configuration values to default values (factory settings)
2: Feedback time the time the beep goes to off
3: Feedback time-out waiting for the wake-up-no-more command
4: feedback beeps per second Amount of beeps a second
5: Mode To configure mode
6: RFID circuit start-up time The time the RFID will be started after pressing “home” or “away”
1: Association group 1 Link devices to the tag reader

1: Set to Default

Set all configuration values to default values (factory settings)

Overview

If the Value is set to 0xFF (255) this device will return to factory settings.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Feedback time

the time the beep goes to off

Overview

0x00 = Off, 0xFF = endless

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 15

3: Feedback time-out

waiting for the wake-up-no-more command

Overview

Too configure the time-out, waiting on the wakeup_no_more_information command before the error sound starts automatically. The error sound is set to 8 short beeps.

0x00 = off

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 255
Default Value 0

4: feedback beeps per second

Amount of beeps a second

Overview

To set the amount of beeps per second, every beep is around 10ms.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 5
Default Value 2

5: Mode

To configure mode

Overview

Mode 1 =  normal working mode

Mode 3 = z-wave chip is always on to be asked for information, for example version or manufacturer ID.

Any other value will be reported after a GET, but will be seen as a mode 1.

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 255
Default Value 1

6: RFID circuit start-up time

The time the RFID will be started after pressing “home” or “away”

Overview

0x64 (100 * 10 ms = 1 s)

The time (*10 ms) the RFID circuit waits to start after “home” or “away” has been pressed.

the time *10 miliseconds, minimum = 0 seconds, max = 2,55 seconds. If the value is not in the allowed size the frame will be ignored.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 255
Default Value 100

1: Association group 1

Link devices to the tag reader

Overview

This class can be used to link other devices to the tag reader. These devices also get the burglar frame send to them.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.