RF9501 15A Light Switch

This describes the Z-Wave device RF9501, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rf9501_00_000.

15A Light Switch

Channels

The following table summarises the channels available for the RF9501 15A Light Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the RF9501 15A Light Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Delayed OFF time The time in seconds the switch will delay when trigger the delayed off feature
2: Panic ON time The time in seconds the switch will turn on for when panic mode is triggered
3: Panic OFF time The time in seconds the switch will turn off for when panic mode is triggered
4: Basic Set Value Setting this to anything other than 0 will cause the value to be transmitted to devices in…
5: Power Up State Power Up State of the switch
6: Panic mode enable Enables this switch to participate in panic mode
1: Group 1  

1: Delayed OFF time

The time in seconds the switch will delay when trigger the delayed off feature

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Panic ON time

The time in seconds the switch will turn on for when panic mode is triggered

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 0

3: Panic OFF time

The time in seconds the switch will turn off for when panic mode is triggered

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 255
Default Value 0

4: Basic Set Value

Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 255
Default Value 0

5: Power Up State

Power Up State of the switch

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options OFF (1)      
  ON (2)      
  Last State (3)      

6: Panic mode enable

Enables this switch to participate in panic mode

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options OFF (1)      
  ON (2)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to