014G0160 Z-Wave room sensor

This describes the Z-Wave device 014G0160, manufactured by Danfoss with the thing type UID of danfoss_014g0160_00_000.

Z-Wave room sensor

Inclusion Information

Push one time LED Button

Exclusion Information

Push one time LED Button

Wakeup Information

Any button (LED, Temp+ or Temp-)

Channels

The following table summarises the channels available for the 014G0160 Z-Wave room sensor.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Setpoint (cooling) thermostat_setpoint_cooling thermostat_setpoint Temperature Number
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (cooling)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 014G0160 Z-Wave room sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Temperature Report threshold Range is from 0.1 to 10°C 1=0.1°C 100=10°C
2: Set-point display resolution range from 0.1 to 10°C 1=0.1°C 100=10°C
3: Min Set-point and override limit from min 0°C to max setpoint override limit 0=0°C 40=40°C
4: Max Set-point and override limit from min setpoint override limit to max 40°C 0=0°C 40=40°C
5: LED Flash period 0 to 65535 seconds
6: Set-point control function 0=Disabled 1=Enabled
7: Temporarily override scheduler 0=Disabled 1=Enabled
8: Set-point type in Thermostat_Setpoint_Reports 1=Heating 2=Cooling 10=Auto Changeover
9: LED on time 1=100ms 5=500ms
10: Number of LED flashes (duration) 0 to 255
11: LED color 1=Green 2=Red

1: Temperature Report threshold

Range is from 0.1 to 10°C 1=0.1°C 100=10°C

Overview

Default value 5 = 0.5 °C

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 1 to 100
Default Value 5

2: Set-point display resolution

range from 0.1 to 10°C 1=0.1°C 100=10°C

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 100
Default Value 5

3: Min Set-point and override limit

from min 0°C to max setpoint override limit 0=0°C 40=40°C

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 40
Default Value 12

4: Max Set-point and override limit

from min setpoint override limit to max 40°C 0=0°C 40=40°C

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 40
Default Value 28

5: LED Flash period

0 to 65535 seconds

Property Value
Configuration ID config_5_4
Data Type INTEGER
Range 0 to 65535
Default Value 1

6: Set-point control function

0=Disabled 1=Enabled

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options disabled (0)      
  enabled (1)      

7: Temporarily override scheduler

0=Disabled 1=Enabled

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options disabled (0)      
  enabled (1)      

8: Set-point type in Thermostat_Setpoint_Reports

1=Heating 2=Cooling 10=Auto Changeover

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 1
Options Heating (1)      
  Cooling (2)      
  Auto-Changeover (10)      

9: LED on time

1=100ms 5=500ms

Property Value
Configuration ID config_9_2
Data Type INTEGER
Range 1 to 5
Default Value 1

10: Number of LED flashes (duration)

0 to 255

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 255
Default Value 5

11: LED color

1=Green 2=Red

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Green (1)      
  Red (2)      

Did you spot an error in the above definition or want to improve the content? You can edit the database here.